Specifies the type of trigger to use to mark a reference point for the measurement.
Remarks
The following table lists the characteristics of this property.
| Short Name | Ref.TrigType |
| Data type | ![]() |
| Permissions | Read/Write |
| Resettable | True |
| Settable While Task Is Running | device-specific |
| Available in Run-Time Engine | True |
| Analog Edge | 10099 | Trigger when an analog signal signal crosses a threshold. |
| Analog Multi Edge | 16108 | Trigger when any of the configured analog signals cross their respective thresholds. |
| Digital Edge | 10150 | Trigger on the rising or falling edge of a digital signal. |
| Digital Pattern | 10398 | Trigger when digital physical channels match a digital pattern. |
| Analog Window | 10103 | Trigger when an analog signal enters or leaves a range of values. The range is in the units of the measurement. |
| Time | 15996 | Trigger when a specified time is reached. |
| None | 10230 | Disable triggering for the task. |