Specifies the action to take if Sample Clock edges occur faster than the device can handle them.

Remarks

The following table lists the characteristics of this property.

Short Name SampClk.OverrunBehavior
Data type ci32.png
Permissions Read/Write
Resettable True
Settable While Task Is Running device-specific
Available in Run-Time Engine True
Stop Task And Error 15862
Stop task and return an error.
Ignore Overruns 15863
NI-DAQmx ignores Sample Clock overruns, and the task continues to run.