Specifies the terminal of the signal to use as the AI Convert Clock Timebase.

Remarks

The following table lists the characteristics of this property.

Short Name AIConv.Timebase.Src
Data type ci32.png
Permissions Read/Write
Resettable True
Settable While Task Is Running device-specific
Available in Run-Time Engine True
Same as Sample Timebase 10284
Use the same source as Sample Clock timebase.
Same as Master Timebase 10282
Use the same source as the Master Timebase.
100 MHz Timebase 15857
Use the onboard 100 MHz timebase.
80 MHz Timebase 14636
Use the onboard 80 MHz timebase.
20 MHz Timebase 12537
Use the onboard 20 MHz timebase.
8 MHz Timebase 16023
Use the onboard 8 MHz timebase.