Counter Input:Count Edges:Count Reset:Input:Hysteresis
- Updated2025-07-28
- 1 minute(s) read
Specifies a hysteresis level applied to CI.CountEdges.CountReset.ThreshVoltage . When CI.CountEdges.CountReset.ActiveEdge is rising, the source signal must first fall below CI.CountEdges.CountReset.ThreshVoltage minus the hysteresis before a rising edge is detected at CI.CountEdges.CountReset.ThreshVoltage . When CI.CountEdges.CountReset.ActiveEdge is falling, the source signal must first rise above CI.CountEdges.CountReset.ThreshVoltage plus the hysteresis before a falling edge is detected at CI.CountEdges.CountReset.ThreshVoltage .
Remarks
The following table lists the characteristics of this property.
| Short Name | CI.CountEdges.CountReset.Hyst |
| Data type | ![]() |
| Permissions | Read/Write |
| Resettable | True |
| Settable While Task Is Running | device-specific |
| Available in Run-Time Engine | True |