Specifies a hysteresis level to apply to CI.Period.ThreshVoltage . When CI.Period.StartingEdge is rising, the source signal must first fall below CI.Period.ThreshVoltage minus the hysteresis before a rising edge is detected at CI.Period.ThreshVoltage . When CI.Period.StartingEdge is falling, the source signal must first rise above CI.Period.ThreshVoltage plus the hysteresis before a falling edge is detected at CI.Period.ThreshVoltage .

Remarks

The following table lists the characteristics of this property.

Short Name CI.Period.Hyst
Data type cdbl.png
Permissions Read/Write
Resettable True
Settable While Task Is Running device-specific
Available in Run-Time Engine True