Counter Input:Period:Input:Hysteresis
- Updated2025-07-28
- 1 minute(s) read
Specifies a hysteresis level to apply to CI.Period.ThreshVoltage . When CI.Period.StartingEdge is rising, the source signal must first fall below CI.Period.ThreshVoltage minus the hysteresis before a rising edge is detected at CI.Period.ThreshVoltage . When CI.Period.StartingEdge is falling, the source signal must first rise above CI.Period.ThreshVoltage plus the hysteresis before a falling edge is detected at CI.Period.ThreshVoltage .
Remarks
The following table lists the characteristics of this property.
| Short Name | CI.Period.Hyst |
| Data type | ![]() |
| Permissions | Read/Write |
| Resettable | True |
| Settable While Task Is Running | device-specific |
| Available in Run-Time Engine | True |