Counter Input:Frequency:Measurement Specifications:High Frequency:Measurement Time
- Updated2025-07-28
- 1 minute(s) read
Specifies in seconds the length of time to measure the frequency of the signal if CI.Freq.MeasMeth is High Frequency with 2 Counters. Measurement accuracy increases with increased measurement time and with increased signal frequency. If you measure a high-frequency signal for too long, however, the count register could roll over, which results in an incorrect measurement.
Remarks
The following table lists the characteristics of this property.
| Short Name | CI.Freq.MeasTime |
| Data type | ![]() |
| Permissions | Read/Write |
| Resettable | True |
| Settable While Task Is Running | device-specific |
| Available in Run-Time Engine | True |