I/O Methods for CAN Modules
- Updated2025-10-09
- 1 minute(s) read
Complete the following steps to use an FPGA I/O Method Node for CAN.
- Specify the configuration properties for the module by right-clicking the CAN module in the Project Explorer window and selecting Properties.
- Create an FPGA I/O item for CAN by right-clicking the FPGA target under My Computer in the Project Explorer window, selecting New»FPGA I/O, and then adding CAN»NI 9852»CAN0 (or CAN»NI 9853»CAN0) and/or CAN»NI 9852»CAN1 (or CAN»NI 9853»CAN1) to the FPGA I/O list.
- Place an I/O Method Node from the FPGA I/O palette onto your FPGA VI diagram.
- Right-click the I/O Method Node, and select Select Item»CAN»NI 9852»CAN0 (or Select Item»CAN»NI 9853»CAN0) or Select Item»CAN»NI 9852»CAN1 (or Select Item»CAN»NI 9853»CAN1).
- Right-click the I/O Method Node and choose Select Method to specify the desired method from the list of CAN methods.
For information on how the I/O Method Node arbitrates with other CAN nodes, refer to
Arbitration.
Note There are no module-specific
methods for NI 9852 or NI 9853. Adding CAN»NI 9852 or
CAN»NI 9853 to the FPGA I/O node and choosing
Select Method does not display any methods.