Interconnecting the Unidirectional SISO (Baseband) Modules

Complete the following steps to connect the modules of the unidirectional SISO (baseband) mmWave Transceiver System configuration.

  1. Connect the adjoining PXIe-3630 and PXIe-7902 High-Speed Serial Instrument modules in the RX chassis using four Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) cables.
    1. Connect the 0 connector of the PXIe-3630 front panel to the PORT 0 connector of the PXIe-7902 front panel.
    2. Connect the 1 connector of the PXIe-3630 front panel to the PORT 1 connector of the PXIe-7902 front panel.
    3. Connect the 2 connector of the PXIe-3630 front panel to the PORT 2 connector of the PXIe-7902 front panel.
    4. Connect the 3 connector of the PXIe-3630 front panel to the PORT 3 connector of the PXIe-7902 front panel.
    Figure 4. Interconnecting the PXIe-3630 and PXIe-7902 Modules

    1378

    1. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cables
  2. Connect the PORT 4 connector of the PXIe-7902 front panel to the PORT 4 connector of the PXIe-7902 front panel using a Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) cable.
    Figure 5. Unidirectional SISO (Baseband) RX Chassis

    1378

    1. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cables
    2. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cable
  3. Connect the adjoining PXIe-7902 and PXIe-3610 modules in the TX chassis using four Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) cables.
    1. Connect the PORT 0 connector of the PXIe-7902 front panel to the 0 connector of the PXIe-3610 front panel.
    2. Connect the PORT 1 connector of the PXIe-7902 front panel to the 1 connector of the PXIe-3610 front panel.
    3. Connect the PORT 2 connector of the PXIe-7902 front panel to the 2 connector of the PXIe-3610 front panel.
    4. Connect the PORT 3 connector of the PXIe-7902 front panel to the 3 connector of the PXIe-3610 front panel.
    Figure 6. Interconnecting the PXIe-7902 and PXIe-3610 Modules

    1378

    1. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cables
    Figure 7. Unidirectional SISO (Baseband) TX Chassis

    1378

    1. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cables

Disconnect cables or otherwise attenuate the signal to ensure that no signal is entering the baseband ports on the PXIe-3630 module during system startup.