NI WSN-3214 Sample Rates
- Updated2023-02-21
- 1 minute(s) read
The following tables show sample rates for the NI WSN-3214 based on the powerline filtering setting or the aperture time setting.
Powerline Filtering
If you use the powerline filtering setting, the following waveform sample rates apply.
| Filter | Max Sample Rate (Hz) (N number of channels) |
|---|---|
| 60 Hz Low Power | 59 |
| 50 Hz Low Power | 49 |
| 60 Hz High Rejection | 30 |
| 50 Hz High Rejection | 25 |
| 50/60 Hz Low Power | 27 |
| 50/60 Hz High Rejection | 13 |
Aperture Time
If you use the aperture time setting, the following waveform sample rates apply.
![]() |
Note Aperture time is only used if powerline filtering is set to None. |
| Channels | 1 | 2 | 3 | 4 |
|---|---|---|---|---|
| Aperture (us) | Max Sample Rate (Hz) | Max Sample Rate (Hz) | Max Sample Rate (Hz) | Max Sample Rate (Hz) |
| 250 | 4096 | 1560 | 1092 | 862 |
| 400 | 2340 | 992 | 697 | 537 |
| 750 | 1260 | 585 | 404 | 306 |
| 1400 | 668 | 321 | 217 | 164 |
| 2800 | 344 | 168 | 113 | 85 |
| 5500 | 175 | 86 | 57 | 43 |
| 10800 | 88 | 43 | 29 | 22 |
| 21500 | 44 | 22 | 14 | 11 |