LabVIEW WSN Module Error Codes
- Updated2023-02-21
- 3 minute(s) read
The LabVIEW WSN Module can return the following error codes. Refer to the KnowledgeBase for more information about correcting errors in the LabVIEW WSN Module.
| Code | Description |
|---|---|
| −25339 | You must enable the serial port receiver power before calling this function, or no new data can be read. |
| −25338 | The device does not support reading or writing the specified number of bytes from the serial port at one time. |
| −25337 | The specified number of bytes cannot be read or written within the specified timeout. |
| −25336 | The specified serial port configuration is unsupported on this device. |
| −25327 | Not enough user RAM. |
| −25326 | Invalid user RAM refnum. This error can occur when you try to perform an operation on a null refnum or a previously closed refnum. |
| −25325 | Verification of user memory failed. |
| −25324 | Failed to write to user memory. |
| −25323 | Failed to write to user memory because the location is not empty. To correct this error, you must erase the entire user memory sector before you can write to the same location again. |
| −25322 | User memory out of bounds. The operation specified a location outside the user memory sector. |
| −25321 | Failed to erase the specified user memory sector. |
| −25320 | Null pointer exception. |
| −25313 | Internal error: Hardware failure. |
| −25312 | The node is not connected. |
| −25311 | Invalid argument. |
| −25310 | User message missed. |
| −25309 | Radio failure: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25308 | Flash failure: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25307 | Command queue overflow: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25306 | Digital output line failure: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25305 | ADC failure: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25304 | CJC failure: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25303 | SPI communication failure: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25302 | Serial receiving failure: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25301 | Serial transmission failure: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25300 | An internal error has occurred in the LabVIEW Wireless Sensor Network Module. Please contact National Instruments technical support at ni.com/support. |
| −25283 | The node ID does not exist in the gateway's node table. |
| −25282 | Invalid message reference. |
| −25281 | Invalid node reference. |
| −25280 | Invalid gateway reference. |
| −25254 | Connection timed out. Gateway might be in a bad state. |
| −25253 | Double interface registration: An internal error has occurred. Please contact National Instruments technical support at ni.com/support. |
| −25252 | Incompatible or corrupted data was received from the gateway. |
| −25251 | Memory error. Unable to deallocate used memory. |
| −25250 | Memory allocation failed. |
| −25230 | The request processor failed to deserialize a request. This error can occur if protocol versions are incompatible or data is corrupt. |
| −25229 | The request processor failed to deserialize a request. This error can occur if protocol versions are incompatible. |
| −25228 | The request terminated due to an unhandled exception. |
| −25227 | Memory allocation failed. |
| −25226 | The client was denied access. |
| −25225 | The client aborted the connection. |
| −25224 | Network communication failed. This error can occur if the gateway IP address is incorrect, the gateway is disconnected, or the gateway is unable to complete the request before timing out. |
| −25223 | Connection timed out. |
| −25222 | Unable to connect to the named service. |
| −25221 | Unable to connect to the named gateway. |
| −25220 | Generic connection error. |
| 21240 | The serial port receiver received a break condition on the line. |
| 21241 | The specified number of bytes were read from the serial port before the specified termination string was detected. |