LabVIEW Simulation Interface Toolkit API Reference

Specifying the Model DLL and Execution Host (Simulation Interface Toolkit)

  • Updated2023-02-21
  • 1 minute(s) read

Complete the following steps to specify the model DLL and execution host for a real-time (RT) simulation.

  1. Configure any necessary RT Series hardware and ensure the hardware is working properly.
  2. Launch LabVIEW and create a host VI.
  3. Select Tools»SIT Connection Manager to launch the SIT Connection Manager dialog box.
  4. Create mappings for parameters and signals you want to manipulate and probe.
  5. Select the Real-Time Target button. If you have not already selected a model DLL, LabVIEW prompts you for the location of the model DLL. If you have not already selected an RT target for the model DLL, LabVIEW prompts you to select the RT target.
  6. Select the appropriate model DLL and click the OK button to return to the SIT Connection Manager dialog box. The Model DLL file path indicator updates to show the path to the model DLL you selected.
  7. Click the Change button next to the Target indicator and specify the IP address of the RT target.
Previous Step
Converting a Model into a Model DLL
Next Step
Creating a Driver VI