Disable Condition VI
- Updated2025-09-30
- 3 minute(s) read
Owning Palette: Alarms and Conditions VIs
Requires: OPC UA Toolkit
Moves a condition to disabled state.
Example
![]() |
OPC UA client refnum in specifies the reference for the OPC UA client. | ||||||||||
![]() |
condition node ID specifies the ID of the condition node. The format of the node ID is ns=<namespace index>;<identifier type>=<identifier>. A node ID contains the following components:
|
||||||||||
![]() |
timeout specifies the maximum time, in milliseconds, that this VI waits to get a response from the OPC UA server. The default is 5000. | ||||||||||
![]() |
error in describes error conditions that occur before this node runs. This input provides standard error in functionality. | ||||||||||
![]() |
OPC UA client refnum out returns the reference for the OPC UA client. | ||||||||||
![]() |
service status returns the status of an OPC UA service call. OPC UA services contain parameters that are conveyed between an OPC UA client and an OPC UA server. | ||||||||||
![]() |
error out contains error information. This output provides standard error out functionality. |
Example
Refer to the OPC UA Demo.lvproj in the labview\examples\Data Communication\OPCUA directory for an example of using the Disable Condition VI.