Time Interval Error VI
- Updated2023-02-21
- 5 minute(s) read
Time Interval Error VI
Owning Palette: Jitter VIs
Requires: Jitter Analysis Toolkit
Measures the differences between the positions in time of waveform level crossings and the times at which the corresponding level crossings occur in the reference clock.

![]() |
data in contains information about the data bit sequence between transitions in a waveform. You can use the Clock Recovery (Mean Clock) VI to generate this cluster.
| ||||||||||||||
![]() |
level crossings contains information about the locations of level crossings in the original waveform. You can use the Level Crossing VI to generate this cluster.
| ||||||||||||||
![]() |
ref level crossings specifies information about the locations of level crossings in the reference clock waveform. You can use the Clock Recovery VIs to generate this cluster from a measured waveform.
| ||||||||||||||
![]() |
error in describes error conditions that occur before this node runs. This input provides standard error in functionality. | ||||||||||||||
![]() |
data out returns information about the data bit sequence between transitions in the waveform.
| ||||||||||||||
![]() |
TIE sequence returns the time interval error measurements. | ||||||||||||||
![]() |
TIE timestamps returns timing information about the waveform that allows you to identify the times at which measurements in the corresponding sequence occur.
| ||||||||||||||
![]() |
error out contains error information. This output provides standard error out functionality. |
Examples
Refer to the following VIs for examples of using the Time Interval Error VI:
- Rj Dj Separation VI: labview\examples\Jitter Analysis\Jitter Measurements
- Rj Dj Delta Delta Separation VI: labview\examples\Jitter Analysis\Jitter Measurements