Owning Palette: Electrical Power VIs

Requires: Electrical Power Toolkit. This topic might not match its corresponding palette in LabVIEW depending on your operating system, licensed product(s), and target.

Use the Power Quality VIs to perform power quality measurement in compliance with IEC 61000-4-7:2009, IEC 61000-4-15:2010, and IEC 61000-4-30:2008.

Palette ObjectDescription
Convert Data to WaveformsConverts resampled voltage and current data to voltage and current waveforms of different line configurations. This VI also arranges the order of the elements in the waveforms of each three-phase electrical power system for further measurement. For example, the orders are A-B-C-N for the four-channel method and A-B-C for the three-channel method. You must manually select the polymorphic instance you want to use.
Initialize SystemSets the basic configuration of the electrical power system based on different line and bus configurations. You must manually select the polymorphic instance you want to use.
SubpaletteDescription
Aggregation VIsUse the Aggregation VIs to aggregate data at a specific interval according to Class S of IEC 61000-4-30:2008.
Events VIsUse the Events VIs to detect voltage dips, swells, interruptions, and rapid change events as defined in IEC 61000-4-30:2008.
Flicker VIsUse the Flicker VIs to measure instantaneous flicker sensation, short-term flicker severity, and long-term flicker severity as defined in IEC 61000-4-15:2010.
Harmonics VIsUse the Harmonics VIs to perform harmonic analysis according to IEC 61000-4-7:2009 and IEC 61000-4-30:2008.
Power & Energy VIsUse the Power & Energy VIs to calculate power and energy values.
Preprocessing VIsUse the Preprocessing VIs to preprocess signals for further power quality analysis.
Scaling & Calibration VIsUse the Scaling & Calibration VIs to scale a signal to the appropriate engineering units if the signal is from a transducer or to scale a secondary-side measured signal to primary-side signal if the signal is from a transformer. You also use these VIs to apply system calibration correction coefficients to the input signal before performing any power quality measurement.
Signaling VIsUse the Signaling VIs to measure mains signaling voltage on the supply voltage as defined in IEC 61000-4-30:2008.
U, I & Freq VIsUse the U, I & Freq VIs to calculate voltage, current, and frequency values for different electrical power data.
Unbalance VIsUse the Unbalance VIs to calculate symmetrical components and analyze voltage and current unbalance as defined in IEC 61000-4-30:2008.
Utility VIsUse the Utility VIs to perform connection conversion between Delta and Wye, perform AC/DC coupling, and set triggers on input data.