SI Set Sampling Rate to System Model VI
- Updated2023-03-14
- 2 minute(s) read
SI Set Sampling Rate to System Model VI
Owning Palette: Model Management VIs
Requires: Advanced Signal Processing Toolkit or Control Design and Simulation Module
Applies a sampling rate to a system model. Use the SI Get Sampling Rate from System Model VI to retrieve the sampling rate from a system model.

![]() |
system model contains information about the model structure, nominal or estimated parameters, identification result, and so on.
|
||
![]() |
sampling rate (Hz) specifies the sampling rate to apply to system model. If system model is a continuous system, set sampling rate to a value less than or equal to 0. | ||
![]() |
error in describes error conditions that occur before this node runs. This input provides standard error in functionality. | ||
![]() |
system model out returns information about the model structure, nominal or estimated parameters, identification result, and so on. | ||
![]() |
error out contains error information. This output provides standard error out functionality. |