Error Codes (Biomedical Toolkit)
- Updated2023-02-21
- 2 minute(s) read
The Biomedical VIs can return the following error codes. Refer to the KnowledgeBase for more information about correcting errors in LabVIEW.
| Code | Description |
|---|---|
| −363255 | The value of End must be greater than or equal to the value of Start. |
| −363254 | In attributes in, the size of the colors array must match the configuration for number of colors. |
| −363253 | The total size of the input medical image files is too large. You can change the scale factor to downsample the images or decrease the number of image files. |
| −363252 | The value of iso value is not valid. |
| −363251 | The values of X pixel spacing, Y pixel spacing, and slice thickness must be greater than 0. |
| −363250 | The sizes of the page, row, and column of the volume data must be greater than or equal to 2. |
| −363233 | The value of high threshold must be greater than the value of low threshold. |
| −363232 | The value of freq bands must meet the following condition: 0≤low≤high≤sampling rate/2. |
| −363231 | The values of systolic threshold and diastolic threshold must be in range [0,1]. |
| −363230 | The number of channels in physical channels must be equal to the number of channels that you configure in the Configure Biosignal Acquisition dialog box or the Configure Biosignal Generation dialog box. |
| −363229 | The interpolation rate must be greater than 0. |
| −363228 | Power distribution parameters, including delta, theta, alpha, and beta, must be in the range [0,1]. |
| −363227 | The value of bin width must be greater than 0. |
| −363226 | The value of isoelectric limit must be greater than or equal to 0. |
| −363225 | The value of threshold factor must be in range [0,1]. |
| −363209 | The file does not support appending data. |
| −363208 | The block size must be greater than 0. |
| −363207 | You must install the NI-DAQmx software to use this VI. |
| −363206 | The sampling rate of the input signal has changed. |
| −363205 | The number of input channels has changed. |
| −363204 | The Channel properties list contains channels with the same name. You must specify a unique name for each channel. |
| −363203 | The sampling rate or the dt of the input waveform must be greater than 0. |
| −363202 | The file or image is not supported. |
| −363201 | The input biosignal or medical image is empty. |
| 363225 | There is no physical channel configured. You must configure physical channels in the Configure Biosignal Acquisition dialog box or Configure Biosignal Generation dialog box. |
| 363250 | DICOM tag names or DICOM tags in contains an unsupported DICOM tag name or DICOM tag ID. |