Starts a new line in the report.

This VI has no affect on Excel reports.


icon

Inputs/Outputs

  • cNI__reportlvclass.png report in

    report in is a reference to the report whose appearance, data, and printing you want to control. Use the Create Report VI to generate this LabVIEW class object.

  • ci32.png number of lines (1)

    number of lines specifies how many lines the VI adds to the report. The default is 1.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • iNI__reportlvclass.png report out

    report out is a reference to the report whose appearance, data, and printing you want to control.

    You can wire this output to other Report Generation VIs.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.