Applies a triangular window (Bartlett Window) to the input signal X. Wire data to the X input to determine the polymorphic instance to use or manually select the instance.


icon

If y represents the output sequence Windowed X, the Triangle Window VI obtains the elements of y from

yi = xitri(w)

for i = 0, 1, 2, …, n – 1

,

where tri(w) = 1 – |w|, and n is the number of elements in X.

Examples

Refer to the following example files included with LabVIEW.

  • labview\examples\Signal Processing\Windows\Window Comparison.vi