Gaussian Window (DBL) VI
- Updated2025-07-30
- 2 minute(s) read
Applies an asymmetrical Gaussian window to the input sequence X. Wire data to the X input to determine the polymorphic instance to use or manually select the instance.

Inputs/Outputs
X
—
X is a real vector.
standard deviation
—
standard deviation is the standard deviation of the Gaussian window normalized to the length of X. The default is 0.2.
Windowed X
—
Windowed X is the input signal with the window applied.
error
—
error returns any error or warning from the VI. You can wire error to the Error Cluster From Error Code VI to convert the error code or warning into an error cluster. |
If y represents the output sequence Windowed X, the Gaussian Window VI obtains the elements of y from:
for i = 0, 1, … , n–1
where n is the number of elements in X, m = (n–1)/2.0, and σ is the standard deviation of the Gaussian window.
Examples
Refer to the following example files included with LabVIEW.
- labview\examples\Signal Processing\Windows\Window Comparison.vi
X
—
standard deviation
—
Windowed X
—
error
—