Remote Panel:Client Request Control
- Updated2025-07-30
- 2 minute(s) read
Requests control of the front panel of a VI on the server computer.
This method is similar to the Request Control of VI shortcut menu item.
This method can return networking error codes.
Parameters
| Name | Data type | Required | Description |
|---|---|---|---|
| VI Name | ![]() |
Yes | Name of the VI or project on the server. To specify a VI that is part of a LabVIEW project, you must include the project name, the project library, and the target in the path of the VI, when applicable. For example, if MyVI.vi resides in a project called MyProject.lvproj under target My Computer, enter the VI name as MyProject.lvproj/My Computer/MyVI.vi. If the VI resides in a project library called MyLibrary, also include the project library in the path, as in MyProject.lvproj/My Computer/MyLibrary.lvlib:MyVI.vi. If the VI is not in a project or project library, you can enter the VI name without any additional information. |
| Server Address | ![]() |
Yes | IP address or computer name of the server. |
| Server Port | ![]() |
Yes | Port on which the Web Server is located. |
Remarks
The following table lists the characteristics of this method.
| Short Name | RP.Client Request Control |
| Data type | No return value |
| Available in Run-Time Engine | Yes |
| Available in Real-Time Operating System | Yes |
| Remote access allowed | No |
Examples
Refer to the following example files included with LabVIEW.
- labview\examples\Data Communication\Remote Panels\Remote Panel Methods.lvproj