RMXPS - Disable Output Step
- Updated2023-02-17
- 2 minute(s) read
RMXPS - Disable Output Step
Use the RMXPS - Disable Output step to disable power generation for the specified RMXPS pins on all sites in the Pin Map context.
Note The RMXPS - Disable Output step
must be used inside of an ECU Multi Test or ECU Action
step with its module adapter configured as Sequence. The RMXPS - Disable Output step
requires the Pin Map context passed from these steps as an input.
Use the RMXPS - Disable Output step edit tab in the TestStand Sequence Editor to specify the Pin Map context and the pins to query to obtain their associated RMX-410x instrument sessions.
RMXPS - Disable Output Step Settings Tab
The RMXPS -
Disable Output Step Settings tab contains the following options:Pin Map Context—Specifies a reference to a Pin Map Context object. This object describes
a subset of pins, sites, and instruments from the pin
map file and provides data pertinent to each site executing
during a test.
Pins—Specifies the pins to query to obtain their associated RMX-410x instrument sessions. These
instrument sessions are used to disable power generation on the
specified pins. The specified pins must be defined in the pin
map file and included in the Pin Map context Pins and Relays
list in the Options tab of the ECU Multi Test step.
Note The RMXPS - Disable Output step filters the pins specified
by instrument type ID. If none of the pins specified have an
instrument type ID of RMX410xPowerSupplyTypeId, the
step will do nothing, as none of the specified pins are connected to
RMX-410x instruments.