FGen - Initiate Generation Step
- Updated2023-02-17
- 2 minute(s) read
FGen - Initiate Generation Step
Use the FGen - Initiate Generation step to initiate waveform generation for the specified FGen pins on all sites in the Pin Map context.
Note The FGen - Initiate Generation step
must be used inside of an ECU Multi Test or ECU Action
step with its module adapter configured as Sequence. The FGen - Initiate Generation
step requires the Pin Map context passed from these steps as an input.
Use the FGen - Initiate Generation step edit tab in the TestStand Sequence Editor to specify the Pin Map context and the pins to query to obtain their associated NI-FGEN instrument sessions.
FGen - Initiate Generation Step Settings Tab
The FGen - Initiate
Generation Step Settings tab contains the following options:Pin Map Context—Specifies a reference to a Pin Map Context object. This object describes
a subset of pins, sites, and instruments from the pin
map file and provides data pertinent to each site executing
during a test.
Pins—Specifies the pins to query to obtain their associated NI-FGEN instrument sessions. These
instrument sessions are used to initiate waveform generation on the
specified pins. The specified pins must be defined in the pin
map file and included in the Pin Map context Pins and Relays
list in the Options tab of the ECU Multi Test step.
Note The FGen - Initiate Generation step filters the pins
specified by instrument type ID. If none of the pins specified have
an instrument type ID of niFGen, the step will do
nothing, as none of the specified pins are connected to NI-FGEN
instruments.