MC Measurement Create.vi
- Updated2025-09-25
- 4 minute(s) read
Purpose
Creates a Measurement object in memory.
Format

Input
|
Conversion Name identifies the referred conversion object defined by MC Conversion Create.vi. | ||||||||||||||||
|
Measurement Name sets the Measurement object name. | ||||||||||||||||
|
ECU ref in is the task reference that links to the selected ECU. This reference is originally returned from MC ECU Open.vi or MC ECU Create.vi. | ||||||||||||||||
|
Address is a cluster that contains the following values:
|
||||||||||||||||
|
Error in is a cluster which describes error conditions occurring before the VI executes. If an error has already occurred, the VI returns the value of the error in cluster to error out.
|
||||||||||||||||
|
Data Type sets the measurement task data type. Data Type can contain the following values:
|
Output
|
ECU ref out is the task reference that links to the selected ECU. | ||||||
|
Error out describes error conditions. If the Error in cluster indicated an error, the Error out cluster contains the same information. Otherwise, Error out describes the error status of this VI.
|
Description
Use MC Measurement Create.vi to create a measurement object in memory instead of referring to a predefined measurement in the A2L database.