Power Input Connectors
- Updated2023-02-17
- 1 minute(s) read
Power Input Connectors
The NI CVS-1459 requires a power supply to power the system. If needed for your application, an additional power source is required to power the isolated outputs.
The same power supply may be used for both the system power and isolated outputs power if isolation is not required and the power supply meets the voltage and power requirements for both inputs. Refer to the NI CVS-1459 Specifications for power requirements.
NI recommends the following power supply for the NI CVS-1459.
| Power Supply | Part Number |
|---|---|
| NI PS-15 Industrial Power Supply, to power the system or isolated outputs | 781093-01 |
- System Power Connector
- Isolated Outputs Power Connector
| Terminal | Description |
|---|---|
| C | Common signal |
| V | System power (12-24 VDC) |
| CISO | Isolated common signal |
| VISO | Power for isolated outputs (5-24 VDC) |