Cable Specifications
- Updated2025-01-22
- 1 minute(s) read
Cables must meet the physical medium requirements specified in ISO 11898, shown in the following table. Belden cable (3084A) meets all these requirements and is suitable for most applications.
| Characteristic | Value |
|---|---|
| Impedance | 95 Ω minimum, 120 Ω nominal, 140 Ω maximum |
| Length-related resistance | 70 mΩ/m nominal |
| Specific line delay | 5 ns/m nominal |