Running Test Sequences Customized for SystemLink
- Updated2023-08-17
- 1 minute(s) read
Running Test Sequences Customized for SystemLink
Before running test sequences, you must install SystemLink Client and connect it to SystemLink Server. TestStand uploads individual DUT reports and test result data to SystemLink Server through SystemLink Client.
- Select to launch the Model Options dialog box.
-
In the Multiple UUT Settings section, configure
Number of Test Sockets.
This number should match the number of DUTs in the batch for each test.
-
In the Sequence File window, select to run test sequences.
Refer to the Loading and Running Sequences section in TestStand Help for more information.