ATCA-3671 Front Panel

Figure 13. ATCA-3671 Front Panel

1378

  1. Red LED
  2. Green LED
  3. Blue LED
Note The signal pins of this product's input/output ports can be damaged if subjected to ESD. To prevent damage, turn off power to the product before connecting cables and employ industry-standard ESD prevention measures during installation, maintenance, and operation.
Table 2. ATCA-3671 Front Panel Connectors
Connector Description
JC OUT Conditioned output clock for CPRI and clock distribution applications.
CLK IN/OUT General purpose clock to and from the FPGA.
AIO Daughtercards for RF front-ends and high-bandwidth expansion modules.
GPIO Low speed, parallel I/O expansion to your module.
SYNC Low skew trigger and clock distribution to FPGAs.
AIO CLK Direct clock distribution to AIO modules.
JTAG JTAG/UART access for system debugging and management.
1Gb ETH Network connection to ATCA-3671 controller.
MGT REF Clock input for GTH reference on FPGAs.
Notice Connections that exceed any of the maximum ratings of any connector on the ATCA-3671 can damage the device and the chassis. NI is not liable for any damage resulting from such connections.
Table 3. ATCA-3671 Front Panel LEDs
Color State Indication
Green Blinking The module is not fully powered on.
Solid The module is ready for use.
Red Blinking A fault has occurred on the board.
Solid The power has failed.
Blue Blinking The module is powering on or there has been a failure.
Solid The module is fully powered off. It is safe to remove the ATCA-3671 from the chassis.
Note When the LED lights are all off, the module is not active.