Specifies how to count and interpret the pulses the encoder generates on signal A and signal B. X1, X2, and X4 are valid for quadrature encoders only. TwoPulseCounting is valid for two-pulse encoders only.

Syntax

Namespace: NationalInstruments.DAQmx

public CIEncoderDecodingType EncoderDecodingType { get; set; }

Remarks

X2 and X4 decoding are more sensitive to smaller changes in position than X1 encoding, with X4 being the most sensitive. However, more sensitive decoding is more likely to produce erroneous measurements if vibration exists in the encoder or other noise exists in the signals.

Exceptions

TypeDescription
NationalInstruments.DAQmx.DaqException