NI-RFSG version 1.7 for Windows 7 / Vista / XP
NI–RFSG 1.7 includes the following new features:
- .NET API Support with installing NI-RFSG .NET Class Libraries
- Support for peer-to-peer streaming with the NI PXIe-5673E. This feature requires updating the firmware on the NI PXIe-5450/5451. Refer to the following bullet for more information about updating the firmware.
- New firmware for the NI PXIe-5450/5451. This firmware upgrade is required for all NI PXIe-5450/5451 devices. After driver installation, refer to the Upgrading Firmware section of the NI-FGEN Instrument Driver Readme at Start»All Programs»National Instruments»NI-FGEN»Documentation.
- Support for the NI PXIe-5653 synthesizer
- Support for LabVIEW 2009 (64-bit), 2010 (32-bit), and 2010 (64-bit)
- Support for list mode for the NI PXIe-5650/5651/5652
- Simulation support for the NI PXIe-5673.
- Support to reset writeable properties and attributes to driver default values
- Support for RF list mode DMA
- Support removed for LabWindows™/CVI™ 7.1.1
NI-RFSG 1.6.3 includes the following new features:
- Includes support for PXIe-5673E RF Signal Generator
NI-RFSG 1.6.2 includes the following new features:
- Fixed the fatal issue when upgrading NI-RFSG on Windows 7 (64-bit) and Windows Server 2008 R2
NI-RFSG 1.6.1 includes the following new features:
- Support NI PXIe-5650/5651/5652
- Support for RF list mode
- Improved tuning times
- Improved harmonics
- Support for external clocking configuration
NI-RFSG 1.5 includes the following new features:
- Support for the NI PXIe–5611 I/Q calibration
- Configurable settling times
- Improved tuning times
- In-band retuning
NI-RFSG 1.4.1 includes the following new features:
- External arbitrary waveform generator (AWG) support for the NI PXIe-5611 I/Q modulator
Minimum Application Development Environments:
You can use NI-RFSG in the LabVIEW and LabWindows/CVI application development environments (ADEs). The minimum versions of these ADEs that can be used with NI-RFSG are listed below.
Supported Application Development Environments:
- NI LabVIEW 8.5.1, 8.6.1, 2009 (32-bit), 2009 (64-bit), 2010 (32-bit), 2010 (64-bit) Full Development System or Professional Development System
- NI LabVIEW Real-Time Module 8.5.1 or later
- LabWindowsTM/CVITM 8.1.1 or later
- LabWindowsTM/CVITM Real-Time Module 9.0 or later
- NI-RFSG .NET Class Libraries 1.0
- Any C compiler capable of calling a 32-bit DLL
Supported Hardware:
NI PXI-5670, NI PXI-5671, NI-PXIe-5672, NI-PXIe-5673, NI PXIe-5673E, NI PXI-5610, NI PXIe-5611, NI PXI-5650, NI PXI-5651, NI PXI-5652, NI PXIe-5650, NI PXIe-5651, NI PXIe-5652, NI PXIe-5653
See readme for full support details