Calculates parameters for use with either MT Modulate QAM or MT Demodulate QAM. The node accepts an M-ary value that specifies a predefined symbol map with the number of distinct symbol map values to use as symbols.

connector_pane_image
datatype_icon

samples per symbol

An even number of samples dedicated to each symbol. Multiply this value by the symbol rate to determine the sample rate.

Note  

The demodulation and detector nodes use timing recovery, which is optimized for four or more samples per symbol.

Default: 16

datatype_icon

M-QAM

The M-ary number, which is the number of distinct states that represent symbols in the complex baseband modulated waveform. This value must be a positive power of 2 and must be less than 256.

Default: 16

datatype_icon

error in

Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

Default: no error

datatype_icon

QAM system parameters

Parameter values defining the QAM system. Wire this cluster to the corresponding system parameters cluster of MT Modulate QAM or MT Demodulate QAM.

datatype_icon

samples per symbol

Number of samples per symbol in the modulated output complex waveform. For error-free operation, the samples per symbol must be an even number.

datatype_icon

symbol map

An ordered array that maps each symbol value to its desired coordinates in the complex plane. The number of QAM states in the array must be 2 N , where N is the number of bits per symbol. The length of the vector for the symbols farthest from the origin must be 1.

datatype_icon

bits per symbol

Number of bits represented by each symbol. This value is equal to Log 2 (M), where M is the order of the modulation (for example, for 16-QAM, M = 16).

datatype_icon

error out