NI LTE Measurement Suite 14.5 - Windows 8/8.1/7/Vista/XP/Server 2008 0 Ratings | 0.00 out of 5 |   Print

Available Downloads:

Updates and Notifications:
Critical Updates and Security Notifications are posted on ni.com. Before downloading, click here to review this information.
Supporting Files:

Download Language: English

Product Line: RF

Version: 14.5

Release date: 02-12-2015

Software type: Addons

Operating system: Windows 8; Windows 8.1; Windows 7; Windows Vista; Windows XP; Windows Server 2008

Description

New Features:

NI LTE Analysis Toolkit 14.5 includes the following new features:

  • Support for 64-bit API
  • Support for LabVIEW 2012 SP1, LabVIEW 2013 SP1 and LabVIEW 2014 SP1

NI LTE Analysis Toolkit 2.0 includes the following new features:

  • Support for time-division duplex (TDD) mode as defined in 3GPP TS 36.211 v8.8.0 specifications
  • Support for analysis of physical uplink shared channel (PUSCH) with sounding reference signal (SRS) as defined in 3GPP TS 36.211 v8.8.0 specifications
  • Support for analysis of physical uplink control channel (PUCCH) with sounding reference signal (SRS) as defined in 3GPP TS 36.211 v8.8.0 specifications
  • Support for demodulation measurements for frame structure type 2 (TDD)
  • Support for auto detection of resource blocks (RBs) for PUSCH with SRS
  • Support for PUSCH and PUSCH channels with SRS spectral measurements
  • Support for power versus time (PvT) measurements for frame structure type 2 for the General ON/OFF time mask for PUSCH and PUCCH
  • Support for complementary cumulative distribution function (CCDF) measurements
  • Addition of a File I/O utility that supports saving and loading toolkit configurations to and from an NI TDMS file. This utility also supports loading acquisitions from an NI TDMS file.
  • Addition of features including on-the-fly configuration changes, digital trigger, and acquisitions saved to an NI TDMS file to the LTE Analysis Soft Front Panel

Supported Hardware

  • NI PXIe-5663
  • NI PXIe-5663E
  • NI PXIe-5665
  • NI PXIe-5668R
  • NI PXIe-5644R
  • NI PXIe-5645R
  • NI PXIe-5646R

System Requirements

Supported Operating Systems

NI LTE Analysis Toolkit 14.5 and later supports the following operating systems:

  • Windows 8.1 (32-bit and 64-bit)
  • Windows 8.0 (32-bit and 64-bit)
  • Windows 7 (32-bit and 64-bit)
  • Windows Vista (32-bit and 64-bit)
  • Windows XP Service Pack 3 (32-bit)
  • Windows Server 2008 R2 (64-bit)

Note  NI LTE Analysis Toolkit 14.5 and later does not support Windows Server non-R2 editions.

NI recommends that you have the most recent service pack for your operating system installed.

Minimum System Requirements

  • Processor—Pentium 4 or equivalent
  • RAM—2 GB
  • Free hard drive space—1 GB
  • Supported RF signal analyzer with minimum 64 MB of onboard memory
  • NI-RFSA 14.0 or later
  • NI LabVIEW Modulation Toolkit 4.4 or later
  • NI LabVIEW Spectral Measurements Toolkit 2.7 or later

Recommended System

  • Processor—Pentium 4 or equivalent
  • RAM—4 GB
  • Free hard drive space—2 GB
  • Supported RF signal analyzer with minimum 64 MB of onboard memory
  • NI-RFSA 14.0 or later
  • NI LabVIEW Modulation Toolkit 4.4 or later
  • NI LabVIEW Spectral Measurements Toolkit 2.7 or later

Application Development Environments (ADEs)

Note  You should install ADEs, such as NI LabVIEW, NI LabWindows/CVI or Microsoft Visual Studio®, before installing NI LTE Analysis Toolkit. To add support for ADEs installed after installing NI LTE Analysis Toolkit, modify your NI LTE Analysis Toolkit installation or launch the NI LTE Analysis Toolkit installer again.

  • LabVIEW 2011 SP1 (32-bit and 64-bit), 2012 SP1 (32-bit and 64-bit), 2013 SP1 (32-bit and 64-bit), or 2014 SP1 (32-bit and 64-bit).
  • LabWindows/CVI 8.5.1 or later.


New Features

NI LTE Generation Toolkit 14.5 includes the following new features:

  • Support for 64-bit API
  • Support for LabVIEW 2012 SP1, LabVIEW 2013 SP1 and LabVIEW 2014 SP1

NI LTE Generation Toolkit 2.0 includes the following new features:

  • Support for generation of frequency-division duplex (FDD) physical uplink control channel (PUCCH) and sounding reference signal (SRS)
  • Support for generation of time-division duplex (TDD) for all supported uplink (UL) and downlink (DL) channels
  • Support for simultaneous generation of UL and DL channels
  • Addition of the File I/O utility that supports saving and loading toolkit configurations to and from an NI TDMS file as well as saving and loading waveforms to and from an NI TDMS file

Supported Hardware

  • NI PXIe-5673
  • NI PXIe-5673E
  • NI PXIe-5644R
  • NI PXIe-5645R
  • NI PXIe-5646R

System Requirements

Supported Operating Systems

NI LTE Generation Toolkit 14.5 and later supports the following operating systems:

  • Windows 8.1 (32-bit and 64-bit)
  • Windows 8.0 (32-bit and 64-bit)
  • Windows 7 (32-bit and 64-bit)
  • Windows Vista (32-bit and 64-bit)
  • Windows XP Service Pack 3 (32-bit and 64-bit)
  • Windows Server 2008 R2 (32-bit and 64-bit)

Note  NI LTE Generation Toolkit 14.5 and later does not support Windows Server non-R2 editions.

NI recommends that you have the most recent service pack for your operating system installed.

Minimum System Requirements

  • Processor—Pentium 4 or equivalent
  • RAM— 2 GB
  • Microsoft Internet Explorer 5.5 or later
  • A screen resolution of 800 x 600 with 256 colors
  • Windows 8/7/Vista/XP SP3, with all available critical updates and service packs
  • Free hard drive space—1 GB
  • Supported RF signal generator with minimum 256 MB of arbitrary waveform generator onboard memory
  • NI-RFSG 14.0 or later
  • NI LabVIEW Modulation Toolkit 4.4 or later

Recommended System

  • Processor—Pentium 4 or equivalent
  • RAM—4 GB
  • Free hard drive space—2 GB
  • Supported RF signal generator with minimum 256 MB of arbitrary waveform generator onboard memory
  • NI-RFSG 14.0 or later
  • NI LabVIEW Modulation Toolkit 4.4 or later

Application Development Environments (ADEs)

Note  You should install ADEs, such as NI LabVIEW, NI LabWindows/CVI or Microsoft Visual Studio®, before installing NI LTE Generation Toolkit. To add support for ADEs installed after installing NI LTE Generation Toolkit, modify your NI LTE Generation Toolkit installation or launch the NI LTE Generation Toolkit installer again.

  • LabVIEW 2011 SP1 (32-bit and 64-bit), 2012 SP1 (32-bit and 64-bit), 2013 SP1 (32-bit and 64-bit), or 2014 (32-bit and 64-bit).
  • LabWindows/CVI 8.5.1 or later.

Installation Instructions

Perform the following steps to install NI LTE Measurement Suite:

  1. Create a temporary folder on your local hard drive and name it NILTE1450
  2. Download the NILTE1450.exe file into the folder you created in step 1.
  3. Goto the NILTE1450 folder.
  4. To launch the NI LTE installer, double-click the NILTE1450.exe program.
  5. Follow the instructions.

To conserve disk space you can delete the downloaded .exe file, however it is recommended that you keep the files in case you need to add features from the NI LTE distribution in the future, or plan to create your own installers using National Instruments development environments.

Your Feedback

Rate this document

Answered Your Question?
Yes No

Submit