Table Of Contents

CI.GPS.SyncMethod

Version:
    Last Modified: May 21, 2018

    Specifies the method to use to synchronize the counter to a GPS receiver.

    Data type: datatype_icon

    Name Value Description
    IRIG-B 10070 Use the IRIG-B synchronization method. The GPS receiver sends one synchronization pulse per second, as well as information about the number of days, hours, minutes, and seconds that elapsed since the beginning of the current year.
    PPS 10080 Use the PPS synchronization method. The GPS receiver sends one synchronization pulse per second, but does not send any timing information. The timestamp measurement returns the number of seconds that elapsed since the device powered up unless you set CI.Timestamp.InitialSeconds.
    None 10230 Do not synchronize the counter to a GPS receiver. The timestamp measurement returns the number of seconds that elapsed since the device powered up unless you set CI.Timestamp.InitialSeconds.

    Long Name:

    Class: DAQmx Task

    Permissions: Read/Write

    Where This Property Is Available:

    Desktop OS: Windows

    FPGA:

    Web Server: Not supported in VIs that run in a web application