Timed Loop (G Dataflow)

Version:
    Last Modified: March 15, 2017

    Executes each iteration of its subdiagram at the period you specify.

    Use the Timed Loop when you want to develop programs with multirate timing capabilities, precise timing, feedback on loop execution, or several levels of execution priority.

    spd-note-note
    Note  

    National Instruments recommends creating no more than one Timed Loop per CPU core on your real-time controller. If you set more than 32 unique Timed Loop priority levels on a single RT controller, the compiler returns an error.

    terminal_icon

    Execution System

    Defines the system settings for the Timed Loop, such as the processor that handles execution of the loop and the priority of the execution of the loop.

    terminal_icon

    Timing Statistics

    Generates execution timing information for each iteration.

    terminal_icon

    Timing Source

    Defines and returns the timing settings for the Timed Loop, such as the loop period and the timing source that controls the loop.

    terminal_icon

    Left Timing Error

    Propagates errors through the loop. The Timed Loop does not execute if this border node receives an error condition.

    terminal_icon

    Right Timing Error

    Propagates errors or warnings out of the loop subdiagram. If this border node receives an error condition, the Timed Loop finishes executing the current iteration untimed, exits the loop, and returns the error condition.

    terminal_icon

    Iteration

    Current loop iteration count. The loop count always starts at zero for the first iteration. The maximum number of iterations is 2,147,483,647, or 231-1.

    If you need to keep count of more than 2,147,483,647 iterations, you can use shift registers with a greater integer range.

    terminal_icon

    Condition

    Determines whether to continue executing the loop. The loop runs infinitely by default. To specify whether the loop stops for a TRUE or FALSE Boolean value, configure the continuation behavior.

    terminal_icon

    Tunnel

    Point through which data enters or exits a structure.

    Tunnels can also assume the following types of functionality:

    • Keep Last Value—Passes the data through the loop border.
    • Auto Index Values For a single loop iteration, either processes one element of an array if the tunnel is an input or appends a piece of data to an accumulating array if the tunnel is an output. To turn on auto-indexing for a tunnel, right-click the tunnel and select Append Mode»Auto Index Values.
    • Concatenating—Appends all elements of the input array in order, forming an output array of the same dimension as the input array. This tunnel concatenates arrays in the same way as the Build Array node.

    You can configure a conditional output for any tunnel type by selecting the tunnel and clicking the Conditional checkbox in the Item tab. When the conditional input for a tunnel is True, the loop writes the corresponding value to the tunnel. When the condition input for the tunnel is False, the loop doesn't write the corresponding value to the tunnel.

    terminal_icon

    Shift Register

    Member of a pair of terminals that passes a value from one iteration of a loop to the next iteration. After the initial loop iteration, the left shift register in the pair returns the value it receives from the right shift register from the previous iteration.

    Refer to Accessing Data from the Previous Loop Iteration for more information about passing values from the previous iteration to the current iteration.

    Late Execution of a Timed Loop Iteration

    A Timed Loop might execute later than the time you specify. For example, higher priority Timed Loops may monopolize processor resources and prevent timely execution of a lower priority Timed Loop. You must configure mode in on the Timing Source node on a Timed Loop to handle late execution.

    Use the following table to compare the mode in options of the Timed Loop.

    mode in Option Effect on Schedule Effect on Data Processing
    1 – Process missed periods, maintain original phase Realigns with the original schedule. Processes data that became available during missed iterations.
    2 – Discard missed periods, maintain original phase Realigns with the original schedule. Discards data that became available during missed iterations.
    3 – Process missed periods, ignore original phase Enables definition of a new schedule that starts at the current time. Processes data that became available during missed iterations.
    4 – Discard missed periods, ignore original phase Enables definition of a new schedule that starts at the current time. Discards data that became available during missed iterations.

    As the table describes, each mode configuration option affects two settings of the Timed Loop:

    • Whether execution of the Timed Loop aligns with the original schedule or enables definition of a new schedule.

      For example, if you set a Timed Loop with a period of 100 ms and an offset of 30 ms, you expect the first loop iteration to execute 30 ms after the first timing source starts running and in multiples of 100 ms after that—at 130 ms, 230 ms, 330 ms, and so on. However, the first execution of the Timed Loop might occur after 240 ms have elapsed. If other Timed Loops or hardware devices are already running at the schedule you specified, you can select option 1 or 2 to configure the Timed Loop to align itself as quickly as possible with the schedule you specified. With this setting, the next Timed Loop iteration will run at 330 ms and continue to run in multiples of 100—at 430 ms, 530 ms, and so on.

      If aligning the Timed Loop with other Timed Loops or other hardware devices is not important, select option 3 or 4 to configure the Timed Loop to run immediately and use the current time as its actual offset. With this setting, the subsequent loop iterations run at 240 ms, 340 ms, 440 ms, and so on.

    • Whether the Timed Loop processes or discards data that becomes available during missed iterations.

      If the Timed Loop is late, it might miss data that other Timed Loops or hardware devices generate. For example, if the Timed Loop misses two iterations and some of the data from the current period, a buffer can hold the data from the missed iterations. Select option 1 or 3 to configure the Timed Loop to process the missed data before it aligns with the schedule. Be aware that processing missed data causes jitter, or a variance between the loop cycle time and the time you specified. To avoid jitter, select option 2 or 4 to configure the Timed Loop to discard older data and process only the latest available data in the buffer.

    Priority of a Timed Loop

    The Timed Loop is a deterministic structure, which means that all Timed Loops execute before any other code on the diagram.

    Period Length of a Timed Loop

    Because of the preemptive nature of Timed Loops, they can monopolize processor resources, not allowing other tasks on the diagram to execute. You must configure the highest priority Timed Loop with a period that is large enough to execute the code on the Timed Loop subdiagram and also have enough idle time during every iteration to allow the rest of the code on the diagram to execute.