Table Of Contents

Configure CPTR Common Reference Edge (G Dataflow)

Last Modified: January 9, 2017

Configures which edge of the common reference is used to generate the CPTR. Configuring the common reference edge is used to account for wiring delays between devices. You must configure the common reference before the Set Time node executes. The Initialize node must execute before this node.

connector_pane_image
datatype_icon

cptr common reference edge

Configures which edge of the common reference the PPS identifies for the CPTR.

datatype_icon

error in

Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

Default: No error

datatype_icon

error out

Error information. The node produces this output according to standard error behavior.

datatype_icon

niUsrpRio session

Object created by the Open node and used as the session handle for the USRP RIO nodes.

datatype_icon

niUsrpRio session (out)

The niUsrpRio session used in all subsequent USRP RIO host nodes.

Where This Node Can Run:

Desktop OS: Windows

FPGA: All devices