USB-6229

产品编号:

32 AI (16-Bit, 250 kS/s), 4 AO (833 kS/s), up to 48 DIO USB Multifunction I/O Device

概述

The USB-6229 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplifies configuration and measurements.

USB-6229 详细信息

产品编号 (20) 价格
780116-12
780116-11
780116-01
780116-02
780116-06
780116-04
780116-07
780116-03
779810-11
779810-12
780116-10
195959-01
779810-10
780116-09
779810-01
779810-03
779810-06
779810-04
779810-07
779810-09
NI Lead Time
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
Number of Bidirectional Digital Channels
—
—
48
48
48
48
48
48
—
—
48
—
48
48
48
48
48
48
48
48
Supported Power Input
—
—
United States 120VAC
Swiss 220VAC
United Kingdom 240VAC
Universal Euro 240VAC
Japan 100VAC
Australia 240VAC
—
—
China 220VAC
—
China 220VAC
Korea 220VAC
United States 120VAC
Australia 240VAC
United Kingdom 240VAC
Universal Euro 240VAC
Japan 100VAC
Korea 220VAC
Maximum Number of Single-Ended Analog Input Channels
—
—
32
32
32
32
32
32
—
—
32
—
32
32
32
32
32
32
32
32
Number of Counters/Timers
—
—
2
2
2
2
2
2
—
—
2
—
2
2
2
2
2
2
2
2
Maximum Number of Differential Analog Input Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Input Absolute Accuracy
—
—
—
—
—
—
—
—
—
—
3100 μV
—
3100 μV
3100 μV
—
—
—
—
—
3100 μV
Analog Input FIFO Buffer Size
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Maximum Sample Rate
—
—
250 kS/s
250 kS/s
250 kS/s
250 kS/s
250 kS/s
250 kS/s
—
—
—
—
—
—
250 kS/s
250 kS/s
250 kS/s
250 kS/s
250 kS/s
—
Analog Input Isolation
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Simultaneous Sampling
—
—
No
—
—
—
—
—
—
—
No
—
No
No
—
—
—
—
—
No
Enclosed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Analog Input Resolution
—
—
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
—
—
16 bits
—
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
Bus Connector
—
—
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
—
—
—
—
—
—
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
—
Front Connection Type
—
—
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
—
—
Screw Terminal(1)
BNC(30)
Generic (OEM)(2)
Screw Terminal(1)
Screw Terminal(1)
BNC(30)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Number of Analog Output Channels
—
—
4
4
4
4
4
4
—
—
4
—
4
4
4
4
4
4
4
4
Maximum Analog Update Rate
—
—
833 kS/s
833 kS/s
833 kS/s
833 kS/s
833 kS/s
833 kS/s
—
—
—
—
—
—
833 kS/s
833 kS/s
833 kS/s
833 kS/s
833 kS/s
—
Reconfigurable
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Analog Input Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Maximum Digital Update Rate
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Operating Temperature Range
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Bus Connection
—
—
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
—
—
—
—
—
—
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
—
Current Flow Direction
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Digital I/O Isolation
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Digital I/O Logic Levels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Maximum Clock Rate
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Digital Input Only Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Digital Output Only Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of External Clock Inputs
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Relay Type
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Signaling Type
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Supports Peer To Peer Streaming
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Input Voltage Range
—
—
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
—
—
—
—
—
—
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
—
Filtering
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Current Output Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Voltage Output Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Output Voltage Range
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Output Current Range
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Output Isolation
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Output Resolution
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Input Maximum Absolute Accuracy
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
产品描述
NI USB-6229 M Series DAQ Device, BNC Term, NI-DAQMX Driver, Taiwan (110V)
NI USB-6229 M Series DAQ Device, BNC Term, NI-DAQMX Driver, Brazil
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, U.S. (120 V)
USB-6229(16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, Swiss (220 V)
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, U.K. (240 V)
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, EURO (240 V)
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, Japan (100 V)
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, Australia (240 V)
NI USB-6229 M Series DAQ Device, Screw Term, NI-DAQMX Driver, Brazil
NI USB-6229 M Series DAQ Device, Screw Term, NI-DAQMX Driver, Taiwan (110V)
USB-6229 M Series DAQ BNC Term, DAQmx, SignalExpress LE, Chinese
NI USB-6229 OEM M Series, Board Only Kit
USB-6229 M Series DAQ Screw Term, DAQmx,SignalExpress LE, Chinese
USB-6229 M Series DAQ BNC Term, DAQmx, SignalExpress LE, Korean
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, U.S. (120V)
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, Australia (240V)
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, U.K. (240V)
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, EURO (240V)
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, Japan (100V)
USB-6229 M Series DAQ Screw Term, DAQmx, SignalExpress LE, Korean

USB-6229 附件和软件

  • 产品 (产品编号)
    说明
    推荐用例
    FlexLogger Professional (785748-3501)
    FlexLogger Professional, Subscription License, Download

    Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.

    Key Features

    • Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
    • Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
    • Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
    • Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
    • Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
    • Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
    • CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
    查看产品详情
    LabVIEW+ Suite (788509-35)
    NI LabVIEW+ Suite, Subscription License, Download

    Recommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.

    The LabVIEW+ Suite includes the following products:

    • NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
    • NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
    • NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
    • NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
    • NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.
    查看产品详情

支持