The following items are Bug Fixes in NI-Digital Pattern Driver 16.0.1 Runtime Patch and PXIe-6570 Firmware 16.0.0f5 BFL.
ID | Legacy ID | Fixed Issue | Issue Details |
---|---|---|---|
603581 |
| PXIe-6570 firmware potential for data corruption | A race condition within the PXIe-6570 firmware (version 16.0.0f1) has the potential to cause data corruption issues. NI strongly recommends that you upgrade the firmware to a newer version immediately. Note: Any PXIe-6570 purchased from National Instruments includes a version of the firmware that has resolved this issue. This issue might be encountered by downgrading to the older 16.0.0f1 firmware version, which was shipped with the NI-Digital Pattern Driver and Digital Pattern Editor 16.0 software distribution. |
637184 |
| Capture memory returns error -1074098097 | Capture memory acquisition stops to prevent an overwrite when the capture memory is not full and PXIe backplane bandwidth is available. This issue might occur as a result of internal latency, which can cause a failure to transfer data. |
637186 |
| Source memory fails to write data | When using source memory, interacting with the device in NI Measurement & Automation Explorer or running the STS Maintenance Software might cause the PXIe-6570 to source incorrect data. |