Archived: LabVIEW 2010 and 2010 SP1 Known Issues by Date

NI does not actively maintain this document.

This content provides support for older products and technology, so you may notice outdated links or obsolete information about operating systems or other relevant products.

Overview



This document contains the LabVIEW 2010 known issues that were discovered before and since the release of the LabVIEW 2010 Development System. Not every issue known to NI will appear on this list; it is intended to only show the severe and common issues.

The LabVIEW 2010 Platform Known Issues contains a full listing of known issues, including LabVIEW toolkits and modules.

Document Organization

There are two versions of the known issues list available:

Known Issues by Category
Known Issues by Date

Please refer to Developer Zone Article "LabVIEW Known Issues Categories Defined" for an explanation of the categories.


Contacting NI

You can contact us by phone, email, or the discussion forums. 

Known Issues by Date

The following items are known issues in LabVIEW 2010 sorted by Date.

219819Center justified tables display improperly when overlapping with the front panel origin
37575 3PD8N0M8LabVIEW uses large amounts of memory when reading an entire wave file at once
39161 401FEQTLThe device ID input of the Play Sound File VI does not work on Windows
39604 49UBP4LEWrite to Clipboard Method consumes 100% of CPU for several minutes
47819 3N68LE002GB file size limit of datalog files
48016 3P7CBB4QUnsigned int32 loses value in formula node when you write to the most significant bit
50420 44CG88SNUpdate the Pulse Transition Measurement Express VI
51185 47FGSQCSCannot save VI as the same name as missing library member VI
51311 477DKPBQLabVIEW does not maintain child-only item setting when dragging an item within a tree
52027 4A4GRP00Cannot use the 'New>>VI for Override...' dialog to create override of password-protected VI unless you have the password
52263 4AJA41TQSome operations on integer waveforms lose dt value
52297 4AIFC0R0Internal error related to locked tab control at fpsane.cpp line 369 and line 367.
91672 477M7K00Large amounts of data in combo box can appear to hang LabVIEW.
36543 4039KEG8Edit-time crashes when many modules, drivers, and toolkits are installed
43109 4FRF0826Cannot customize plot legend with background image in LabVIEW
45133 4I0976O4The coercion of an enum through its digital display behaves differently in the development environment than in a LabVIEW executable.
105509The "do not save automatic changes" setting does not affect libraries
117209Bundle by Name does not break VI when fields from the input cluster's typedef are deleted
97181On a Mac, a VI that writes waveform data to a chart on the Web Server crashes the Web browser when accessed from a PC
118949Tab control local variables generate value change events when you use a multi-column ListBox
45802 4IDA53I0Using VI Server Get/Set [Variant] Control Values on Clusters with Fixed Size Arrays creates error 2
118106Variant To Flattened String and Flattened String To Variant Do Not Support Fixed Point Data Type
119444Multi-column listbox format lost on upgrade
120686Write to LabVIEW Measurement Files (LVM) using Express VIs takes up a lot of memory
122057Joining Numbers of Different Widths Produce Unexpected Values
123313Unnecessary IAK file checked into source code control
43671 4GID11F2Opening VI Properties Window takes a long time
51179 47B12U5UError 6 occurred at Create Folder in Create Directory Recursive.vi when building an application (EXE), shared library (DLL), source distribution or web service
45360 4I0EE2BQLocalization Codes do not Function for Timestamp Controls
138552Load VRML File.vi missing "error in" terminal
119204Plot Legend Does Not Update When Using Property Nodes
141699NI Distributed System Manager does not show deployed libraries if they contain non-Latin characters.
148149Event Structure Cases can Incorrectly Remap to Other Dynamic Events
157246The Property Node "Bring to Front" doesn't work in Windows Vista
124783Sound Input Read VI does not return samples requested
128059Shared variable bindings in the same library are not updated properly when copying/renaming the library
162800"Wait on Notification from Multiple" returns inconsistent results when multiple refnums refer to same named notifier
147187Crash using Xscale Info or YScale Info graph properties
164268Tab control incorrectly displays ComponentWorks 3D Graph when other tabs are selected "Page Labels Display"
166253LabVIEW.app does not show up after LabVIEW 2009 Installation
178273"Must Override" doesn't break descendant classes if ancestor implementation is renamed
181687Web publishing tool fails without error
173080When a project that contains variables with binding is created in one language and opened in a different language, variables may fail to deploy
185059Member VIs of a class that is a member of a project library have a red X on them in the palettes
163371"Save As:Copy" on a nested library breaks member VIs if use option to add copied library to owner library
173963Pressing "Stop" while dropping Snippet with SubVI that cannot be located hangs LabVIEW
174929Repeated Loading & Unloading of the Analysis Library Generates Exception
168005Dynamic Variable API Does Not Support I/O Servers that Use Ranges
169840Large matrix operations that utilize the Intel MKL on Linux may crash LabVIEW
103315Creating a circular link between an Xcontrol and a LVClass can crash LabVIEW.
154260Context Help does not update for controls or indicators placed in a tab control on front panel
158446When comparing a sub array created through the Array Subset Function with an identical Array the result is false.
167056Wiring cluster of fixed point values to waveform chart causes a broken arrow
176856VI Snippet of a VI with Dynamic inputs results in a LabVIEW crash
95055Save for previous fails if file path is too long
198717Unflatten From XML fails for cluster and arrays that consist of variants
208364LabVIEW built installers created on a 32-bit machine will not install most drivers when run on a 64-bit machine
213279Some nodes may crash or yield incorrect/inconsistent results when Inlined
212136"The VI is not executable. The full development version of LabVIEW is required to fix the errors" dialog on a built app
206944Version in DataSocket Server About Box is incorrect
208088Updating the Labels of a Cluster Written to a Chart Does Not Update the Cluster Used for Chart History
207352Moving a .NET Assembly while LabVIEW is open will cause an error the next time it is called from LabVIEW.
223244"File is not a resource file." popup on a built app
198955Default Parameters cannot be deleted from .NET assembly parameter list
164604Calling LabVIEW built .NET Interop Assembly from same version of LabVIEW causes a hang
188911Control image alignment incorrect when "new report page" VI is used
202702RT Remote Panel license is not released when tab or browser window is closed
227609Statically linking a LabVIEW built DLL in a C++ project results in error 998 if the DLL is not added to the Delay Loaded DLLs list
231877Polymorphic VIs with "Adapt to Type" set can choose wrong instance VI
153731Unhandled Exception can occur if absolute path for system DLL used in CLFN
185890Text on a VI can be mutated to appear as Unicode
218083VIs with errors may show additional errors for code in disabled frames of Conditional Disable Structure
221113CLFN with the wrong calling convention may silently crash LabVIEW
227030Wait on Notification from Multiple function has unexpected behavior when ignoring previous input.
229641Hang can occur when deploying RT project that has not been check out of VSS
230799Crash on exit in process which calls a LabVIEW-built shared library on Linux
232348Changes to a library item's access scope sometimes do not update broken callers.
235446LabVIEW Installer doesn't install .NET support if only .NET 4.0 is installed.
242603LabVIEW 2010 crashes on compile if you have a divide primitive with dominator less than 1 wired to the for loop count terminal (N)
318415Error reading LVM file "Incorrect file type"
237587Using "^" in an Expression Node will result in a broken VI
243004Web Method VIs' Boolean Control Terminals are Inverted when Web Service is Called
231024Network Streams do not support Fixed Point range and delta
232466Replace with Programmatic Access is misleading for RT FIFO Enabled Shared Variables
233205Network Streams do not support enums, data types w/ units, substrings, subarrays, & fixed-size arrays
233209An array of Stream refnums can incorrectly display access type
234411RT Web Service Build error 1502
235019OpenSSL fatal error when LabVIEW exits
236817NI-Auth does not work with Firefox
237673Refreshing Distributed System Manager with an item selected will remove the item from the display
243106Broken wires or bad terminals with Insert Into Array primitive crashes LabVIEW 2010
251397Broken wires or bad terminals with Insert Into Array primitive crashes LabVIEW 2010
242799Code generation of DAQmx Assistant for Modular Instrument Express VIs fails on second attempt in LabVIEW 64-bit
243468Default Namespaces not supported in XML Parsing VIs
185226FXP configuration diffs don't show up when comparing VIs
242778Library (or class or XControl) may become corrupted by saving a reference to non-existant untitled VI
246375Unexplained broken wire when local variable of Chart control interacts with uninitialized shift registers
246540NI-Auth permissions get reset in build specification
246593Power of X and Y-th Root of X returns incorrect result when using single precision numbers
249370In LabVIEW 2010 on a Mac, you cannot save VIs with the .vit and .ctt file extensions
176848Picture Control Stops Updating After Setting Properties to Default.
244148Certain Trigonometric Functions Return Incorrect Results in LabVIEW 2010 when Using Extended Precision Inputs
247384TestStand Error -18004 When Attempting to Configure or Execute LabVIEW 2010 VIs While Debugging My LabVIEW User Interface in LabVIEW 2010
136677Remote panels do not work if Internet Explorer is embedded in an ActiveX or .NET Container
187247ActiveX functions return error 1 if using a 64-bit integer
192280Open UFF58 VI will cause a hang if built into an application
196607DTbl Replace Subset VI behavior change between LabVIEW 8.6.1 and 2009
196742Load STL Geometry VI cannot load binary STL files
226840Formula VI does not execute pow(x,y) function
236377Dropping XControl from public library breaks XControl
243625Nested libraries cause unnecessary dirty dot.
246966Write to Text File output changed from LabVIEW 2009 to 2010 if the user selects cancel in the file dialog
247628Reading a TDMS file written using DAQmx Configure Logging VI may result in an out of memory error.
248914Changing the order of controls or deleting controls in a type def cluster can change references
248965Deploying an executable that uses SSL with the HTTP Client API will error out
285210Read from Measurement File Express VI can read incorrect data
322914Formula VI does not execute pow(x,y) function
256141Windows 7 often shows "(Not Responding)" and will bring other windows to the front during expensive operations
235775LabVIEW crashes in assembly deployment if lkads.exe is not running on Vista/Windows 7
242600A search dialog can appear when building a source distribution where the main destination is a library
248065Application Builder fails with Error 74 with upgraded .NET and a dll call
248421Bitshift does not work correctly in Expression Nodes and Formula Nodes with a data type smaller than I32
250119LabVIEW crashes if you delete a compound arithmetic primitive with a breakpoint
251094HTTP Post Reports Error 42 When Executing a FSWS Download with a 1MB File
251229Adjusting X-Scale Multiplier Property Affects Graph Annotations
254821LabVIEW built executable with network streams won't exit process
255627Remote Panels not working in LV 2010 built executables
300558LabVIEW built executable with network streams won't exit process
300592LabVIEW built executable with network streams won't exit process
250588Warning Generated in a Method or Property of an XControl Appears as an Error in the Top Level VI
246263LabVIEW Class Properties don't output or produce invalid input in LabVIEW, crash or produce invalid output in built applications
221992LabVIEW Constructor node cannot load dlls written in .net 4.0
292464The function GaussHG returns NaN for X values less than 0.
249566LabVIEW 2010 crashes with fpsane.cpp line 442 when "Modifications:Front Panel (or Block Diagram) Mods Bitset" property is used
244158LabVIEW 2010 crashes with image2.cpp line 250 when opening a VI with a constant set to 'View As Icon'
276334On VxWorks targets, the TDMS Defragment VI shows Error 6 and deletes the file it is operating on in the U:\ drive
258485FTP VIs do not close session if there is an error
277392Typecast of object with different binary size may crash LabVIEW
255466Shared variable moved from a project directly to a tab control is not added to the active page.
256559Including .vi in web method name and using "?" as a query separator causes app web server to crash
256928LabVIEW crashes when closing a VI reference to a reentrant VI with shared clones when using TestStand
257197Error Constant erroneously added to Variant to Data
258758Setting digits of precision in Distributed System Manager has no effect.
276831Output of zero generated from the multiply node with certain DAQmx properties and VIs when using highlight execution
277049Changing a missing Type Definition Control to a constant crashes LabVIEW
277283When creating a VI Snippet with code that contains a tab control, the snippet does not properly save the contents of each tab.
245609Swapping Connector Pane terminals loses Required status
246681lvwsdsc not generated correctly unless your VI is in your project directory
255982Child Class Property Node does not output until deleting and rewiring any part of the VI
257275Format Into String does not work with the %d format for numbers larger than I32
276928Opening a TDMS file with LabVIEW 2010 can produce error -2503
278559Nested classes in a packed project library breaks a VxWorks VI.
279298Deploying a VI with OO Accessors can cause internal error 1394
254317LabVIEW can crash when deleting broken wires.
192804Error 91 occurred at the Variant To Data node
236193Crash with invalid input (o or negative values) of "samples per channel" when misusing TDMS Set Channel Information
245148Class Properties dialog sometimes throws timeout error 123 when opening and must be restarted
251105S&V XControls built as Remote Panel crashes LabVIEW.
251951HTTP Client VI calculates wrong dll path when built into a built app on LV RT
276766Flat Sequence Structure leak GDI Objects, wasting memory and eventually crashing LabVIEW
278029Changing an case selector from I64 to U32 can cause a corruption
281124Nested diagram disable structures can cause LabVIEW to no compile.
256238Last iteration of parallel for loop may not execute in parallel when it has non-indexing output tunnels
289842Get Variant Attribute VI returns wrong value if attribute not found
2387133D Picture Controls can display transparently or crash LabVIEW on certain graphics cards
255617Error 1502 can occur if dependencies are placed in non executing case structures
283943Many VI Server methods work across contexts and use variants, which can crash LabVIEW when provided with context sensitive data (such as LabVIEW Classes).
284688Japanese LabVIEW 2010 SP1 fails to launch when a third party toolkit is installed.
284936Breaking one Override VI in LVOOP shows all siblings as broken but does not explain why
289559Dynamically launching reentrant VIs is slower and requires more memory.
186808Shared Variable library on PC is undeployed if the a V in the same project is programmatically deployed to a Real-Time target
284289Source distributions with block diagrams removed prevents the use of static Shared Variable nodes.
306205Error 1003 when building an executable with OpenTrace.vi within a LabVIEW Class
252270Stacked chart will not update all points if Digital Display is visible and on top of the chart
279373SMTP has been updated to use port 587; LabVIEW makes use of legacy port 25
282737Applications with Chinese characters in the executable name will throw fatal error on English Windows 7
283709Logos Sockets should broadcast on all available NICs
284802Programmatically enabling shared variable alarm leads to deployment error and mismatch between shared variable properties and the multivariable editor.
292599Using Array Selection Size[] or Selection Start[] Properties can crash LabVIEW 64-bit
293342Preallocated reentrant LabVIEW Class Property accessors cause LabVIEW to crash
294285Type Defined Shared Variable not found in Executable
294981Creating a copy of a class and adding it to the current project from the Save As dialog may crash LabVIEW
305928Saving a VI that has separated compiled code will leak memory
308464LabVIEW cannot build some large applications because it fills the image table.
306797Cannot create indicator/control/constant for refnum datatypes from XML property and invoke nodes
179603Call Parent Node input must be the same as dynamic dispatch terminal.
112702Cannot read file that shows up as zero bytes.
187412Custom RTM will incorrectly link to the source location when built into an executable
250532ConnectorPane.cpp can cause a VI to be unable to load
321876VI Password Protection can be defeated
233061 4AQA5L00LabVIEW crashes after working with Simulation Subsystem using a LabVIEW Class
327431Import WebService Tool doesn't work for HTTPS protocol
338840Shortcut Menu Activation Interferes with Independent Autoscale Y Settings in Waveform Chart or Graph with Multiple Plots
186525'visarc' file included in source distribution even when excluding vi.lib
333279Calling the System Exec VI after calling the Pipe VI in LabVIEW for Linux will Hang LabVIEW.
239631Memory Growth with TDMS Write
303503When a LVM file is read by the Read from Measurement File Express VI, the Y Unit attribute is ignored.
191423LabVIEW does not execute properly when certain .NET properties are changed on the .NET RichTextBox control
286917DSC Periodic I/O Servers run as SYSTEM and creates a security vulnerability
244551Editing large strict type definitions can take a long time to update
288455Shared Variable Not Updated When Changing Representation
342148Boolean reference as first item in cluster can causes LabVIEW crash
202192LabVIEW UDP broadcast is inconsistent across different OS's.
218947IO Variable items under copy-pasted C Series modules lose custom names & configuration
241160Multiple Instances of a control in an unbundle by name function causes indicators not to update
358049When a specific VI is opened, and then closed, LabVIEW remains in the task bar, with no windows open.
359369Application Font change not applied correctly when pasting text
239719Property page doesn't update when Adapt to Source is coerced to off
245359Selecting a newer version of a .NET assembly does not reload assembly
257506Write Binary on array of extended / complex extended with no array size information writes invalid data when set to write native byte ordering.
258226Remote Panels cannot be viewed by Safari for Mac OS X 10.6 or later
369142Front Panels may stop updating with 3+ monitors with Windows Aero enabled
365679LabVIEW 3D Picture control does not work with certain AMD video card drivers
184689UI Performance degredation when displaying NaN values on 3D Surface Graph in LabVIEW
257735Class VIs that call shared variables in a library in an auto-populating folder will not be loaded
367445Source distribution of a class which uses dynamic dispatch can become broken looking for a missing subVI
389991Memory leak when calling LabVIEW DLLs from C with new threads.
305978Save As Duplicate with Include All Dependencies makes a Copy of the instr.lib Folder.
392232Autopreallocate Arrays and Strings VI Property Can Crash LabVIEW when not in FPGA Context
408790Palette Editor Cannot Add LabVIEW Classes
453896Error message encountered during TestStand Deployment Utility build process may show incorrect list of VIs
465817LabVIEW converts a Double Precision numeric "NaN" value to integer data types differently since LabVIEW 2010
372668The channel order is incorrect for the first TDMS group after using NI_MinimumBufferSize property.
445175Two or more Static VI References between the same VIs with different strictness can result in broken executables from Application Builder

 

Known Issues

IDKnown Issue
219819

Return
Center justified tables display improperly when overlapping with the front panel origin
When you add a table control to the front panel so that it overlaps with the vertical origin of the front panel, LabVIEW displays center justified columns off center when you type text. The cells appear to float or move horizontally until aligned with the vertical origin. Formerly tracked as 50061 and 42NAR8SA

Workaround: Move the table away from the front panel's vertical origin.

Reported Version: 8.0.1  Resolved Version: N/A  Added: 09/01/2007
37575
3PD8N0M8

Return
LabVIEW uses large amounts of memory when reading an entire wave file at once
The Sound File Read VI uses large amounts of memory to read an entire .wav file.

Workaround: Read the data from the .wav file in sections rather than in one large file.

Reported Version: 8.0  Resolved Version: N/A  Added: 09/01/2007
39161
401FEQTL

Return
The device ID input of the Play Sound File VI does not work on Windows
On Windows, LabVIEW ignores the device ID input of the Play Sound File VI. This VI plays sound only on the default sound card.

Workaround: Use the Sound Output Configure VI and the Sound Output Write VI with the Sound File Open VI and the Sound File Read VI or the Sound File Simple Read VI. Refer to the Sound File to Sound Output example VI for an example of this workaround.

Reported Version: 8.0.1  Resolved Version: N/A  Added: 09/01/2007
39604
49UBP4LE

Return
Write to Clipboard Method consumes 100% of CPU for several minutes
If you try to copy a large amount of data from LabVIEW to the clipboard, LabVIEW slows significantly and might become unresponsive.This was previously tracked as CAR 90497 and 3YJ87JCM

Workaround: N/A

Reported Version: 8.2.1  Resolved Version: 2013  Added: 09/01/2007
47819
3N68LE00

Return
2GB file size limit of datalog files
The maximum size of datalog files is 2 GB.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 09/01/2007
48016
3P7CBB4Q

Return
Unsigned int32 loses value in formula node when you write to the most significant bit
If you wire a hex value greater than x7FFFFFFF as an unsigned, 32-bit integer to a Formula Node, LabVIEW coerces the value to 0. If you use a negative number for U32 input/output variable, LabVIEW will coerce the value to 0.

Workaround: 1. Use the Mathscript node or LabVIEW code for the operation that involves an unsigned, 32-bit integer.2. Use signed 32-bit integers instead of unsigned 32-bit integers in the formula node.

Reported Version: 8.0  Resolved Version: N/A  Added: 09/01/2007
50420
44CG88SN

Return
Update the Pulse Transition Measurement Express VI
The terminology and measurement definitions for the Transition Measurements VI comply with IEEE Standard 181-2003, IEEE Standard on Transitions, Pulses, and Related Waveforms. However, the Timing and Transition Measurements Express VI does not comply with this IEEE Standard.

Workaround: The Slew rate refers to the transition slope. The Preshoot refers to the pre-transition undershoot (rising pulse) or the pre-transition overshoot (falling pulse). The Overshoot refers to the post-transition undershoot (rising pulse) or the post-transition overshoot (falling pulse).

Reported Version: 8.5  Resolved Version: N/A  Added: 09/01/2007
51185
47FGSQCS

Return
Cannot save VI as the same name as missing library member VI
If a library contains a VI and the VI is missing, you should be able to save a VI as the same name as the missing VI in order to rebuild the missing VI. Currently, LabVIEW does not allow this.

Workaround: Delete the item from the library, save the new VI as the same name as the missing VI and then move the VI into the library.

Reported Version: 8.5  Resolved Version: N/A  Added: 09/01/2007
51311
477DKPBQ

Return
LabVIEW does not maintain child-only item setting when dragging an item within a tree
If you have a tree item with the child-only setting, and then drag it within the tree, LabVIEW loses the child-only setting.

Workaround: Use tree events to (1) get the child-only flag setting when the user begins a drag, and (2) reset the child-only flag after completing a drop.

Reported Version: 8.2.1  Resolved Version: N/A  Added: 09/01/2007
52027
4A4GRP00

Return
Cannot use the 'New>>VI for Override...' dialog to create override of password-protected VI unless you have the password
You use the 'New>>VI for Override...' dialog to override an ancestor VI in a LabVIEW class if the VI you want to override is password-protected.

Workaround: Make a public VI which wraps the functionality of the private VI, and instruct others to override the public VI.

Reported Version: 8.5  Resolved Version: N/A  Added: 09/01/2007
52263
4AJA41TQ

Return
Some operations on integer waveforms lose dt value
Some functions, such as Absolute Value and Logarithm Base 10 operate as you expect with DBL Waveforms, but when you apply the same functions to an I16 waveform, for example, the Absolute Value function works as you expect while the Logarithm Base 10 function loses the sampling interval dt value. LabVIEW resets the sampling interval dt value to 1.00. If the input waveform to the log function has a time stamp for t0, that value is also lost.

Workaround: Extract the Y-array of the waveform and perform the needed operations on Y before re-building the waveform.

Reported Version: 8.0.1  Resolved Version: 2013 SP1  Added: 09/01/2007
52297
4AIFC0R0

Return
Internal error related to locked tab control at fpsane.cpp line 369 and line 367.
If you lock a tab control that is already locked using Group»Lock, you might see two internal errors and LabVIEW may crash.

Workaround: Do not lock a control that is already locked.After the fact: copy the Tab Control from the block diagram into a new VI. It will show up unlocked in the new VI.

Reported Version: 8.5  Resolved Version: 2012 32-bit  Added: 09/01/2007
91672
477M7K00

Return
Large amounts of data in combo box can appear to hang LabVIEW.
If you place a large amount of data in a combo box, on the order of megabytes, LabVIEW appears to hang by taking a long time to calculate wrapping.

Workaround: N/A

Reported Version: 8.2  Resolved Version: 2013  Added: 09/01/2007
36543
4039KEG8

Return
Edit-time crashes when many modules, drivers, and toolkits are installed
Edit-time crashes during various operations (right-click menu selection, VI save, moving a VI from one block diagram to another, building an application [executable], shared library, or source distribution, etc.) can result from LabVIEW's image table overflowing from large amounts of palette icons being loaded in memory due to many installed modules, drivers, and toolkits. In this scenario, may receive LabVIEW error log files reporting "You filled the image table" in image.cpp.

Workaround: In Tools->Options->Controls/Functions Palettes, change the Palette Loading from "Load palettes in background" (default behavior) to "Load palettes when needed" and restart LabVIEW. This workaround does not work if you:

1. Perform a palette search.
2. Click "place me on diagram/front panel" from the LabVIEW Help.

Reported Version: 8.0.1  Resolved Version: 2012 32-bit  Added: 10/08/2007
43109
4FRF0826

Return
Cannot customize plot legend with background image in LabVIEW
You cannot configure a plot legend with a custom background image in LabVIEW.

Workaround: Make the color of the plot legend transparent, and place the image behind it. This only works if your plot legend remains a fixed size in a fixed location.

Reported Version: 8.5  Resolved Version: 2011 32-bit  Added: 01/23/2008
45133
4I0976O4

Return
The coercion of an enum through its digital display behaves differently in the development environment than in a LabVIEW executable.
The coercion of an enum through its digital display behaves differently in the development environment than in a LabVIEW executable. Neither produce an out of range value, but one coerces to the last entry in the enum, the other leaves the enum unchanged.

Workaround: Use an event structure to capture value change filter events and restore the enum to the value you choose. You can also disable the digital display for the enum.

Reported Version: 7.1  Resolved Version: 2012 32-bit  Added: 02/22/2008
105509

Return
The "do not save automatic changes" setting does not affect libraries
The "do not save automatic changes" options setting does not affect any type of library, including classes.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 06/20/2008
117209

Return
Bundle by Name does not break VI when fields from the input cluster's typedef are deleted

Workaround: Change the data type (numeric to string, string to numeric) of the cluster element to be deleted to force breakage at all references to that member. Repair the broken VIs and then remove the cluster element. Or you can delete the cluster element, save (keeping the control open), then mass compile.

Reported Version: 8.5.1  Resolved Version: 2011 32-bit  Added: 07/08/2008
97181

Return
On a Mac, a VI that writes waveform data to a chart on the Web Server crashes the Web browser when accessed from a PC
When posting a VI that writes waveform data to a chart inside a loop on the Web Server for remote front panels on a Mac, accessing the remote front panel from a PC may crash the Web browser.

Workaround: Use graphs instead of charts. If chart functionality is necessary, you can programmatically create a history of data that gets plotted to the graph on each plot.

Reported Version: 8.2  Resolved Version: 2012 32-bit  Added: 07/08/2008
118949

Return
Tab control local variables generate value change events when you use a multi-column ListBox
A value change event is generated when a Tab Control local variable's value is changed in an Event Structure that was triggered by a double-click/ value Change on a multi-column ListBox.

Workaround: Use Value Property Node for the Tab Control instead of Local Variable to change the Tabs.

Reported Version: 8.2.1  Resolved Version: 2011 32-bit  Added: 07/10/2008
45802
4IDA53I0

Return
Using VI Server Get/Set [Variant] Control Values on Clusters with Fixed Size Arrays creates error 2
The VI Server get/set [variant] control values if used on a cluster with fixed sze arays, results in an error. This is expected as LabVIEW core does not support fixed size arrays. Fixed size arrays are meant to be used only with LabVIEW FPGA.

Workaround: Pull the array outside the cluster for running on the development computer.

Reported Version: 8.6  Resolved Version: 2011 32-bit  Added: 07/10/2008
118106

Return
Variant To Flattened String and Flattened String To Variant Do Not Support Fixed Point Data Type
The Fixed Point data type is not supported by the Variant To Flattened String and Flattened String to Variant functions. You may see a crash when trying to unflatten this datatype in conjunction with an empty fixed point array.

Workaround: Either use a supported datatype or do not use the Variant.

Reported Version: 8.5  Resolved Version: 2011 32-bit  Added: 07/11/2008
119444

Return
Multi-column listbox format lost on upgrade
A Multicolumn listbox created in LV 7.1 may lose its format when opened in LV 8.5 or later. Column headers lose their 3D appearance and font formatting might be lost.

Workaround: Replace the Listbox and recreate all customizations

Reported Version: 8.5  Resolved Version: N/A  Added: 07/12/2008
120686

Return
Write to LabVIEW Measurement Files (LVM) using Express VIs takes up a lot of memory
The "Write to Measurement File" Express VI consumes a large amount of memory when writing to a Text File (LVM). However, the memory usage is smaller when the same Express VI is used to write a TDM/TDMS File

Workaround: Use general LabVIEW VIs (and not Express VIs) to perform an LVM write for large amounts of data. The other option would be to write in smaller chunks.

Reported Version: 7.1  Resolved Version: N/A  Added: 08/11/2008
122057

Return
Joining Numbers of Different Widths Produce Unexpected Values
The Join Number VI produces different results when the inputs are of different widths/sizes.

Workaround: Explicitly cast to same size before joining.

Reported Version: 8.0  Resolved Version: 2014  Added: 08/20/2008
123313

Return
Unnecessary IAK file checked into source code control
When NI-FieldPoint is installed, and source code control is configured for LabVIEW, when you check in projects to source control the source code provider attempts to check in an IAK file for the project, even if one does not exist.

Workaround: If a dialog appears when checking in file, do not check in the iak file if it is not necessary for that project.

Reported Version: 8.5  Resolved Version: 2011 32-bit  Added: 08/20/2008
43671
4GID11F2

Return
Opening VI Properties Window takes a long time
When I try to open the VI properites window of a VI it takes a very long time to open. This can occur when you are using a network shared printer (as printer default), and that printer is offline.

Workaround: Set default printer to "Microsoft Office Document Image Writer" for example.

Reported Version: 8.5  Resolved Version: 2011 32-bit  Added: 09/02/2008
51179
47B12U5U

Return
Error 6 occurred at Create Folder in Create Directory Recursive.vi when building an application (EXE), shared library (DLL), source distribution or web service
When building a Build Specification, the build process fails with Error 6 at Create Folder in Create Directory Recursive.vi. This usually happens if the path one of the files generated by the build (temporarily during the build process or as part of the output) is too long. The operating system requires paths for files to be less than 255 characters.

Workaround: 1. Use a shorter path for your build destination (i.e. c:\build\) and if necessary copy the output to the final location you need.2. A. For application (EXE) and shared library (DLL) build specifications, place a checkmark in the Use LabVIEW 8.x file layout checkbox on the Advanced page of the Properties dialog box.2. B. For source distribution or web service build specifications, uncheck the Preserve disk hierarchy checkbox on the problem Destination on the Destinations page of the Properties dialog box.

Reported Version: 8.2.1  Resolved Version: N/A  Added: 10/06/2008
45360
4I0EE2BQ

Return
Localization Codes do not Function for Timestamp Controls
According to the help, localization codes are available for format strings. They allow to specify the decimal separator and override the system decimal separator. However, this doesn't work for the Timestamp "advanced format" option.

Workaround: If you would like to discuss this issue and possible workarounds, please visit the NI Discussion Forums

Reported Version: 8.5  Resolved Version: 2012 32-bit  Added: 12/09/2008
138552

Return
Load VRML File.vi missing "error in" terminal
In LabVIEW 8.6, the "error in" terminal was removed from the Load VRML File.vi. LabVIEW 8.2/8.5 has this terminal. Thus, if a VI that has the Load VRML File VI is upgraded to 8.6, the previously working VI will be broken.

Workaround: Place a case structure around the Load VRML File VI to handle the error manually.

Reported Version: 8.6  Resolved Version: 2013  Added: 01/14/2009
119204

Return
Plot Legend Does Not Update When Using Property Nodes
When the properties of a plot legend are changed by property node or by a reference and a property node, the legend does not redraw.

Workaround: A redraw can be forced by changing the property node Plot.Name, changing the property node Legend.Visible, or a mouse movement over the plot legend.

Reported Version: 8.5  Resolved Version: 2012 32-bit  Added: 01/27/2009
141699

Return
NI Distributed System Manager does not show deployed libraries if they contain non-Latin characters.
If a library with non-Latin characters (such as Japanese, Chinese, or Korean) is deployed, it will not show up in the NI Distributed System Manager tree view.

Workaround: Rename the library using only the Latin alphabet and re-deploy the library.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 02/10/2009
148149

Return
Event Structure Cases can Incorrectly Remap to Other Dynamic Events
When deleting a user event refnum from a cluster which is input to a Register For Events Function, the associated Event Structure cases can be swapped.

Workaround: Make sure User Events registered multiple times like this have unique names. On the attached VI, all the User Events have the same name "Event A". Popup on each Event refnum control, choose "Show Control", then show the control's label and renamed it to match the top-level type name, or some other unique name.

Reported Version: 7.1  Resolved Version: 2013  Added: 03/13/2009
157246

Return
The Property Node "Bring to Front" doesn't work in Windows Vista

Workaround: N/A

Reported Version: 8.6.1  Resolved Version: N/A  Added: 04/20/2009
124783

Return
Sound Input Read VI does not return samples requested
If the user inputs a value of "number of samples/ch" into the Sound Input Read VI and the waveform that this returned is only 75% of the samples.

Workaround: N/A

Reported Version: 8.5.1  Resolved Version: 2012 32-bit  Added: 04/28/2009
128059

Return
Shared variable bindings in the same library are not updated properly when copying/renaming the library
If you have shared variables in a library which are bound to I/O servers or other variables that are also in the same library, and you rename or save a copy of the library, the bindings still refer to the original library name.

Workaround: Manually rebind the variables after copying or renaming the library.

Reported Version: 8.0  Resolved Version: N/A  Added: 04/28/2009
162800

Return
"Wait on Notification from Multiple" returns inconsistent results when multiple refnums refer to same named notifier
When using the "Wait On Multiple Notifications" primitive, problems have been observed if two refnums in the input array refer to the same named notifier. These problems apply if the exact same refnum is included multiple times or if different refnums to the same notifier are included. If the Wait node executes and there is already a notification available then the output refnum array will include every refnum that refers to the underlying notifier (including multiple copies of the same refnum) and there will be N copies of the notification in the output notification array, one for each output refnum. If the Wait node does have to go to sleep, when Send Notification executes, the Wait will wake up but will return an array containing only a single refnum and one copy of the notification.

Workaround: You can use Notifier Status function on each of the refnums passed as input to the Wait function in order to get the names of all those notifiers. When the Wait function returns its results, use the Notifier Status function to get the name of the returned notifier, then search the original list for all refnums that have the same name as the one returned. This allows you to identify the original refnums that should have been returned.

Reported Version: 6.1  Resolved Version: 2011 32-bit  Added: 04/28/2009
147187

Return
Crash using Xscale Info or YScale Info graph properties
Graph properties Xscale Info and YScale Info available in LabVIEW 6.0 are no longer available. Using these properties will cause your VI to crash when executed.

Workaround: Use newer individual properties XScale.Range etc. to adjust your graph properties.

Reported Version: 8.2  Resolved Version: 2011 32-bit  Added: 04/30/2009
164268

Return
Tab control incorrectly displays ComponentWorks 3D Graph when other tabs are selected "Page Labels Display"
Tab Controls display remnants of ComponentWorks 3D graph when toggling through the pages using Page Labels Display. The issue does not occur when manually clicking on the Page names, or when changing the value of the tab with the tab's terminal, a local variable, or a Value property node.

Workaround: Change the value of the tab directly on the terminal, with a local variable, or a Value property node.

Reported Version: 8.6  Resolved Version: 2011 32-bit  Added: 06/16/2009
166253

Return
LabVIEW.app does not show up after LabVIEW 2009 Installation

Workaround: This is only an issue for customers who installed the LabVIEW 2009 Beta for Mac. Delete /Library/Receipts/LabVIEW*9.0.pkg before running the LabVIEW 2009 installer for Mac OS.

Reported Version: 2009 32-bit  Resolved Version: Unknown  Added: 07/31/2009
178273

Return
"Must Override" doesn't break descendant classes if ancestor implementation is renamed
On a parent class, mark one dynamic dispatch VI as "Must Override". Now add an override VI in the child classes so that the hierarchy is not broken. Now do Save As:Rename on the parent VI. The child classes should be broken because they no longer have an override for the VI that changed its name, but they are not broken.

Workaround: Unloading the classes and reloading them will correctly break the classes.

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 07/31/2009
181687

Return
Web publishing tool fails without error
The web publishing tool may fail to start the web server if the port is already reserved, yet not return an error.

Workaround: Ensure that the port to be used by the web server is not in use.

Reported Version: 8.6  Resolved Version: N/A  Added: 08/03/2009
173080

Return
When a project that contains variables with binding is created in one language and opened in a different language, variables may fail to deploy

Workaround: Open the project in the desired language, double-click on the variables with binding, and re-bind the variables.

Reported Version: 8.6  Resolved Version: N/A  Added: 09/08/2009
185059

Return
Member VIs of a class that is a member of a project library have a red X on them in the palettes
Normally this red X only appears when you put private or unlicensed VIs into the palettes. VIs marked with this red X still drop on block diagrams successfully.

Workaround: You can create a set of Merge VIs that are not part of the class that have just a single subVI on their block diagram that is the class VI you wanted to drop.

Reported Version: 2009  Resolved Version: 2012 32-bit  Added: 09/08/2009
163371

Return
"Save As:Copy" on a nested library breaks member VIs if use option to add copied library to owner library
Old Description :"Save As:Copy" on a nested library breaks member VIs if use option to add copied library to owner libraryIf you have a nested library, a library that is owned by another library, and you use Save As:Copy, there is an option to add the duplicate library to the original owner library. If you use this option, the member VIs of the duplicate library are all broken because they are not correctly named as members of the owning library.This bug affects all types of libraries, .lvlib, .lvclass, .xctl and .lvsc.

Workaround: Option 1: Do not use the "add to owning library" option and instead add the duplicate library to the owner manually after the copy.
Option 2: After the copy operation, open and close one of the new VIs and then move the duplicate library out of the owner library. Browse to any missing VIs that pop up a browse dialog. Move the duplicate library back into the owner library.

Reported Version: 8.5  Resolved Version: N/A  Added: 09/30/2009
173963

Return
Pressing "Stop" while dropping Snippet with SubVI that cannot be located hangs LabVIEW

Workaround: Do not press Stop, use Ignore instead.

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 09/30/2009
174929

Return
Repeated Loading & Unloading of the Analysis Library Generates Exception
This problem has only been reproduced on Linux using the latest versions of MKL v10.x, and has been reported to Intel as 545399. Some analysis VIs in LabVIEW use Intel's Math Kernel Library (MKL) internally to compute results. Opening these VIs or using them on another VI's diagram loads the MKL library. When all references to these analysis VIs are closed, the MKL library is unloaded from memory.When working with a VI that use these analysis VIs, the following development patterns can lead to this problem:1. Dynamically opening and closing references to the VI while no references to the analysis VIs are in memory.2. Iteratively opening and closing the VI while no other analysis VIs are loaded in memory.3. Using the File >> Close All operation in between editing one or more VIs that use the analysis VIs.

Workaround: To avoid the exception, the MKL library must remain in memory during the entire LabVIEW session. You can achieve this in many ways:1. Open the front panel of an analysis VI that loads MKL and keep it open until exiting LabVIEW.2. Open a reference to an analysis function that loads MKL and close the reference before closing LabVIEW.The A x B.vi from the Mathematics >> Linear Algebra palette is an example of analysis function that serves this purpose.

Reported Version: 2009 32-bit  Resolved Version: 2014  Added: 09/30/2009
168005

Return
Dynamic Variable API Does Not Support I/O Servers that Use Ranges
You cannot use the Variable classes, properties, and methods or the associated Shared Variable functions (Dynamic Variable API) to dynamically read and write PSP items published by an I/O Server that uses a Range item. For example, Modbus I/O Servers and Lookout Ranges are affected by this issue.

Workaround: If you want to use the Dynamic Variable API to read or write one of these PSP items, you can create a network-published shared variable and bind it to the PSP item. Then you can use the Dynamic Variable API to read and write the bound shared variable.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 11/10/2009
169840

Return
Large matrix operations that utilize the Intel MKL on Linux may crash LabVIEW
When one or more matrix operations consumes most of the system resources, the Intel MKL library produces an unhandled exception that results in a LabVIEW application crashing.This Intel library is used to accelerate fundamental linear algebra operations performed under Linux operating systems. This issue has been reproduced outside the LabVIEW execution environment and a bug report has been submitted to Intel.Because the crash is tied to system resources, it can manifest itself in many ways. For example, we have reliably reproduced the problem by:1. Decomposing a large matrix into multiple large matrices.Specific example: Computing the singular value decomposition (SVD) of a 2500-by-2500 matrix on a system with 256M RAM.2. Simultaneously computing multiple matrix operations using relatively small matrices.Specific example: Computing 30 matrix expressions using 300 x 300 matrices on a system with 512 MB RAM.

Workaround: If you have identified one or more matrix operations in your application that exhibit this behavior, you have multiple options to avoid crashing.1. Serialize the matrix operations so that they are not consuming resources in parallel.2. Replace affected matrix arithmetic functions using Basic Linear Algebra Subroutine (BLAS)functions found on the BLAS palette.3. Structure your application so that these operations are not competing with other functions for system resources.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 11/10/2009
103315

Return
Creating a circular link between an Xcontrol and a LVClass can crash LabVIEW.
The circular load leads to VIs that are permanently broken and no matter what you do the run arrow will not become fixed.

Workaround: Do not create a circular link from your XControl to your class. In other words, write your class completely and then write your XControl using the class. Do not put the XControl or any property/invoke node for the XControl into member VIs of the class.

Reported Version: 8.5.1  Resolved Version: N/A  Added: 11/17/2009
154260

Return
Context Help does not update for controls or indicators placed in a tab control on front panel

Workaround: Right click on the item in the tab control and go to Properties»Documentation and add a custom Description for that item. Doing so will then allow the custom description and the data type to be shown in the context help when mousing over the item.

Reported Version: 8.6  Resolved Version: 2011 32-bit  Added: 11/17/2009
158446

Return
When comparing a sub array created through the Array Subset Function with an identical Array the result is false.

Workaround: 1. Place after the "Array Subset" function a "Reshape Array" function.2. Replace the "Array Subset" function through "Delete from Array" function3. Turn off auto-preallocate arrays and strings.

Reported Version: 8.6  Resolved Version: 2011 32-bit  Added: 11/17/2009
167056

Return
Wiring cluster of fixed point values to waveform chart causes a broken arrow

Workaround: Change the representation of the number wired into the cluster to something like I64, then back to FXP

Reported Version: 8.6.1  Resolved Version: 2012 32-bit  Added: 11/17/2009
176856

Return
VI Snippet of a VI with Dynamic inputs results in a LabVIEW crash
Previously tracked as CAR 182023

Workaround: N/A

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 11/17/2009
95055

Return
Save for previous fails if file path is too long
Save for previous copies the folder being saved to a temp location; if the resulting file paths exceed the limit defined by the OS, the function fails.

Workaround: Copy the folder being saved to the root directory to reduce the file path length and Save for Previous from that location.

Reported Version: 8.5  Resolved Version: N/A  Added: 11/17/2009
198717

Return
Unflatten From XML fails for cluster and arrays that consist of variants
Creating a cluster that contains a variant or building an array of variants, and then trying to flatten it to XML using the Flatten To XML VI and then unflattening it using the Unflatten From XML VI will throw error 1106

Workaround: N/A

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 02/01/2010
IDKnown Issue
208364

Return
LabVIEW built installers created on a 32-bit machine will not install most drivers when run on a 64-bit machine
If you build an installer using LabVIEW on a 32-bit machine that contains National Instruments drivers, the corresponding drivers will not be installed if the installer is run on a 64-bit machine. Drivers such as NI-DAQ, NI-Sync etc. are affected by this issue. Installation on 32-bit machines are not affected by this bug.

Workaround: Workaround: On the deployment 64-bit machine, download and install the missing drivers from ni.com

Reported Version: 8.5  Resolved Version: N/A  Added: 02/16/2010
213279

Return
Some nodes may crash or yield incorrect/inconsistent results when Inlined
An Inline public methodVI calling a private-scope method VI, inlined into a non-class caller may give a runtime error when trying to call the private method from the inlined code in the non-class caller.

Workaround: Do not try to Inline VIs with these nodes.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 02/19/2010
212136

Return
"The VI is not executable. The full development version of LabVIEW is required to fix the errors" dialog on a built app
If you have a built application that contains a polymorphic VI in a LabVIEW library which has an instance VI that is private, and a VI outside the LabVIEW library calls the polymorphic VI, this error might occur in the built application.

Workaround: In App Builder, under "Additional Exclusions", uncheck the "Remove unused polymorphic VI instances" option.

Reported Version: 2010 32-bit  Resolved Version: 2012 SP1  Added: 03/08/2010
206944

Return
Version in DataSocket Server About Box is incorrect
The About Box of the DataSocket Server always displays version 4.5, regardless of the installed DataSocket Version (4.5/4.6/4.7).

Workaround: N/A

Reported Version: 2009 32-bit  Resolved Version: 2014  Added: 03/09/2010
208088

Return
Updating the Labels of a Cluster Written to a Chart Does Not Update the Cluster Used for Chart History
Changing the Label of elements in a cluster written to the Waveform Chart does not update the label of the cluster when read from the Waveform Chart Data History Property.

Workaround: Temporarily wire up a completely different data type to the Waveform chart indicator and then rewire the original cluster. The changes will now propagate to the Chart History.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 03/09/2010
207352

Return
Moving a .NET Assembly while LabVIEW is open will cause an error the next time it is called from LabVIEW.
Changing the location of a .NET DLL causes the following error to occur when calling the DLL with a .NET constructor node:Error 3 occurred at Constructor Node in [VI name]Possible reason(s):LabVIEW: Internal error. Wrong memory zone accessed.

Workaround: Close LabVIEW and then move the assembly. You will have to relocate it when opening LabVIEW. Note: It is always recommended to use a project when using .NET code in LabVIEW. You should only have the relocated the assembly in the project.

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 05/19/2010
223244

Return
"File is not a resource file." popup on a built app
If the startup VI of a built app does not have the ".vi" extension, this error might occur in the built application.

Workaround: Change the startup VI to have a ".vi" extension.

Reported Version: 2009 32-bit  Resolved Version: 2011 64-bit  Added: 05/19/2010
198955

Return
Default Parameters cannot be deleted from .NET assembly parameter list
The .NET interop assembly utility's Define VI Prototype Dialog Box states that 'return value' is the only parameter that cannot be deleted, but any value connected to the connector pane is included by default, and none of these can be deleted. The X (delete) button is disabled.

Workaround: None - building a wrapper around the built DLL to only expose the parameters desired, or not allowing the parameter to be default (disconnect from connector pane)

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 06/04/2010
164604

Return
Calling LabVIEW built .NET Interop Assembly from same version of LabVIEW causes a hang
If you build a .NET Interop Assembly and try to call it in the same version of LabVIEW, it will hang at the constructor node

Workaround: Create the .NET Interop Assembly in a different version of LabVIEW.

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 06/16/2010
188911

Return
Control image alignment incorrect when "new report page" VI is used
When using Append Control Image to Report.vi, the alignment of some images are ignored when New Report Page.vi is used between appended images. This problem only exists with Office 2007. Other versions - Office 2003 and Office 2010 do not exhibit this behavior.

Workaround: Use a New Report Line.vi between appending the image and the New Page.vi

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 06/16/2010
202702

Return
RT Remote Panel license is not released when tab or browser window is closed
Attempting to connect to remote front panel on real-time target from multiple tabs or windows in a browser causes remote front panel to exceed the connections. Closing these tabs or windows does not release the license connection. Therefore the exceeded connection limit message persists until the target is rebooted.

Workaround: Reboot the RT target to reconnect to the remote front panel.

Reported Version: 2009  Resolved Version: 2011 32-bit  Added: 06/16/2010
227609

Return
Statically linking a LabVIEW built DLL in a C++ project results in error 998 if the DLL is not added to the Delay Loaded DLLs list
For more information see this KnowledgeBase

Workaround: Go to the Project Property Pages, Configuration Properties»Linker»Input and add the name of your DLL to the Delay Loaded DLLs list.

Reported Version: 7.1.1  Resolved Version: N/A  Added: 06/16/2010
231877

Return
Polymorphic VIs with "Adapt to Type" set can choose wrong instance VI
With a polymorphic VI with instance VIs that take a floating point type and an integer type, the "Adapt to Type" mechanism may incorrectly choose the integer type instance VI when a floating point type with more precision is wired in. For example, if a polymorphic VI has one instance VI that takes an I32 and one that takes a Single Precision floating-point number, when wiring in a Double Precision floating-point number the polymorphic VI will choose the I32 version.

Workaround: Coerce the input data type to correspond to the desired instance VI.

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 06/16/2010
153731

Return
Unhandled Exception can occur if absolute path for system DLL used in CLFN
If you use a specific path to a system DLL (C:\windows\system\user32.dll) and build your VI into an application it will create a copy of the DLL inside the application. This can cause an unhandled exception when running

Workaround: LabVIEW searches in the system directory when looking for DLLs. If you are using a system DLL simply put the name in the in DLL Path box in the CLFN properties. In the example above you would simply put "user32.dll"

Reported Version: 8.6  Resolved Version: N/A  Added: 07/23/2010
185890

Return
Text on a VI can be mutated to appear as Unicode
After building a project into an executable, various text for controls and indicators changes languages. It appears that the text was interpreted as Unicode.We have not been able to reproduce this in house to find a definite cause. Because of this we will leave this CAR open even though we have created code to recover from the corruption if it happens.Previously tracked as CAR 179683

Workaround: Upgrade the VI to LabVIEW 2011. In 2011 we put in code to only view text on VIs as unicode if the UseUnicode=True is in the LabVIEW .ini file. Previously this would only switch on the ability to change something to unicode.When the VI is upgraded to 2011 it should be saved and then saved for previous to return it to the original version. 

Reported Version: 8.6.1  Resolved Version: N/A  Added: 07/23/2010
218083

Return
VIs with errors may show additional errors for code in disabled frames of Conditional Disable Structure
If you have a VI that has errors in it, there may be additional errors shown. The errors will be in code that is inside of a disabled frame of the Conditional Disable Structure (in the "Default" or "Windows" frame when on RT).

Workaround: Fix the other errors in the VI, and the additional errors should go away.

Reported Version: 2010  Resolved Version: N/A  Added: 07/23/2010
221113

Return
CLFN with the wrong calling convention may silently crash LabVIEW
LabVIEW 8.5 through 2009 could adjust the calling convention at run time if the user selected the wrong option. In 2010 this no longer happens. More information is found in KnowledgeBase 59KB14WI

Workaround: Use the correct calling convention

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 07/23/2010
227030

Return
Wait on Notification from Multiple function has unexpected behavior when ignoring previous input.

Workaround: See KB

Reported Version: 8.0  Resolved Version: N/A  Added: 07/23/2010
229641

Return
Hang can occur when deploying RT project that has not been check out of VSS
When using VSS source code control for a real time project and trying to deploy code that has not been checked off the deployment window blocks a pop up from VSS saying that the code has not been checked out. The deployment status window is modal so it does not allow you to select to proceed in the VSS window.

Workaround: In the LabVIEW project properties disable the prompts from source code control. Or you could make sure that the VIs are saved prior to deploying.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 07/23/2010
230799

Return
Crash on exit in process which calls a LabVIEW-built shared library on Linux
A process which calls a LabVIEW-built shared library may crash on exit in some cases because the LabVIEW runtime engine is still trying to clean up while the process is shutting down. This usually happens only when the main process links directly to the LabVIEW-built shared library or when the shared library is loaded dynamically and then unloaded just before exiting. This should not happen if sufficient time passes between the unloading of the shared library and exiting the process.

Workaround: Load the LabVIEW-built shared library dynamically using dlopen, close it using dlclose, and then sleep for around 100ms (ex, usleep(100000); ) before exiting the process.

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 07/23/2010
232348

Return
Changes to a library item's access scope sometimes do not update broken callers.
Changing a library item's access scope sometimes does not update callers which are broken only because they were attempting to access an item which was out of scope to them.

Workaround: Force recompile (ctrl+click on the run arrow) any VI which incorrectly believes that access scope forbids access to it's dependency. Changing the access scope to another value, then back to the desired value while the VI is open will also fix the issue.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 07/23/2010
235446

Return
LabVIEW Installer doesn't install .NET support if only .NET 4.0 is installed.
If you are using a machine that ONLY has .NET 4.0 our installer will not install .NET support. This should only be a problem with Window XP as later version of Windows install .NET 3.5 by default

Workaround: Install .NET 3.5 and restart the installation

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 07/23/2010
242603

Return
LabVIEW 2010 crashes on compile if you have a divide primitive with dominator less than 1 wired to the for loop count terminal (N)
LabVIEW 2010 will crash on save, or load from a previous version (pre-2010) of any VI that meets all of the following conditions:1. Contains a For Loop with an upstream computed constant expression wired to N2. The computed constant expression must contain a divide primitive somewhere3. The computed denominator must be a floating point value that would coerce to an integer value of zero (-0.5 < x < 0.5)

Workaround: This has been fixed in the LabVIEW 2010 f2 Patch

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 07/29/2010
318415

Return
Error reading LVM file "Incorrect file type"
If you save data to a LVM file using the "Overwrite once, then append to file" mode, you can potentially get an error when reading this file back. The error will show up as "incorrect file type". The problem is that the step reads back the file in 65K chuncks and if this chunk happens to end in the middle of a header section, the step will give this error.

Workaround: A potential workaround is to add a few extra lines in the beginning of the file and thus shifting where the next 65k chunk starts. Also, in general, the LVM file type is not the best file format for overwriting the file with multiple sections, thus it's better not to use this mode

Reported Version: 2010  Resolved Version: 2012 32-bit  Added: 07/30/2010
237587

Return
Using "^" in an Expression Node will result in a broken VI
Using "^" operand in an Expression node will cause a VI to fail to compile. This is not the correct operand to use if you want to use exponents. Use a double asterisk "**" instead as it is the correct syntax

Workaround: Use "**" instead of "^"

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 08/02/2010
243004

Return
Web Method VIs' Boolean Control Terminals are Inverted when Web Service is Called
Web method VIs in 2010 have an issue effecting Boolean inputs. If a Boolean control is an input of a web method VI the value of this Boolean is the inverted when the web method is called.

Workaround: This has been fixed in the LabVIEW 2010 f2 Patch

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 08/02/2010
231024

Return
Network Streams do not support Fixed Point range and delta
Network Streams strip FXP range and delta from data types because LogosXT currently does not support them.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 08/03/2010
232466

Return
Replace with Programmatic Access is misleading for RT FIFO Enabled Shared Variables
The Programmatic Shared Variable API does not support RT FIFOs for network-published Shared Variables. If a network-published Shared Variable with RT FIFOs enabled were to be converted from a static node to programmatic access using the "Replace with Programmatic Access" option from the right-click menu the generated code would not be functionally equivalent.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 08/03/2010
233205

Return
Network Streams do not support enums, data types w/ units, substrings, subarrays, & fixed-size arrays
The Network Streams API does not support all LabVIEW data types. In an unsupported data type is used as an input to the data type terminal of a Create Stream Writer Endpoint VI or Create Stream Reader Endpoint VI error -314304 will occur.

Workaround: KB 5ASGQ2GI: Why Do I Get Error -314304 When Using Network Steams?

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 08/03/2010
233209

Return
An array of Stream refnums can incorrectly display access type
An array of Stream refnums with different access types will incorrectly display acces type if the array is created with the build array function.

Workaround: To to create a control or indicator compatbile with your array, you have create an array of this type on a diagram, create a control or indicator from that array wire, and then copy the control or indicator to the place you want to use it.

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 08/03/2010
234411

Return
RT Web Service Build error 1502
When building a web service for an RT Target error 1502 can occur. This error can occur when building a web service with a web method that contains a VI from the Web Services Palette.

Workaround: Check the "Remove unused member of project libraries" in the Additional Exclusions category of the Web Service build specification.

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 08/03/2010
235019

Return
OpenSSL fatal error when LabVIEW exits
The OpenSSL fatal error possibly occurs when using Search features in LabVIEW for the first time after installation.

Workaround: Launch LabVIEW and exit when Getting Started Window opens. The error now goes away in future launchings.

Reported Version: 2010 32-bit  Resolved Version: Unknown  Added: 08/03/2010
236817

Return
NI-Auth does not work with Firefox
Web Services using NI-Auth work incorrectly in Firefox. A user's log in credentials will never be accepted.

Workaround: Use Internet Explorer

Reported Version: 2010 32-bit  Resolved Version: Unknown  Added: 08/03/2010
237673

Return
Refreshing Distributed System Manager with an item selected will remove the item from the display
When an item within a process such as a Shared Variable or a I/O channel is highlighted and the user refreshes the display the high lighted item will be removed from the display. This will not remove the items from Shared Variable Engine be inaccessable from hardware or other applications.

Workaround: Highlight a system or process and click refresh. This should restore the missing item to the display.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 08/03/2010
243106

Return
Broken wires or bad terminals with Insert Into Array primitive crashes LabVIEW 2010
Certain cases such as broken wires or bad terminals associated with the Insert Into Array primitive results in a crash when upgrading code from LabVIEW 2009 (or earlier) to LabVIEW 2010

Workaround: This has been fixed in the LabVIEW 2010 f2 Patch

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 08/09/2010
251397

Return
Broken wires or bad terminals with Insert Into Array primitive crashes LabVIEW 2010
Certain cases such as broken wires or bad terminals associated with the Insert Into Array primitive results in a crash when upgrading code from LabVIEW 2009 (or earlier) to LabVIEW 2010

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 08/09/2010
242799

Return
Code generation of DAQmx Assistant for Modular Instrument Express VIs fails on second attempt in LabVIEW 64-bit
When dropping a DAQmx Assistant or or a Modular Instrument Express VI, everything, including code generation, works the first time, but if another Express VI is dropped, the config page appears, but no code is generated when the user presses [OK].

Workaround: For all versions of LabVIEW 32-bit on the 64-bit machine, disable the VI Server TCP/IP checkbox, exit, and try the code generation again in LabVIEW 64-bit.

Reported Version: 7.0  Resolved Version: 2011 32-bit  Added: 08/17/2010
243468

Return
Default Namespaces not supported in XML Parsing VIs
When trying to work with XML Parsing VIs you will get error -2768Possible reason(s):LabVIEW: The XPath expression does not conform to XPath syntax. Refer to the W3CXPath Web site at http://www.w3.org/TR/xpath for more information about XPath syntax.

Workaround: Remove the default namespace (example: remove xmlns="http://www.ieee.org/ATML/2007/TestResults"),

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/17/2010
185226

Return
FXP configuration diffs don't show up when comparing VIs
Front panel type differences will be reported, but not node configurations

Workaround: Manually Inspect

Reported Version: 2009  Resolved Version: 2013 SP1  Added: 08/30/2010
242778

Return
Library (or class or XControl) may become corrupted by saving a reference to non-existant untitled VI
If you create a new, untitled VI in a library (including .lvlib, .lvclass and .xctl files) and then disconnect the untitled VI from the library but keep the VI open in memory, the library will often not actually disconnect entirely from the VI, and when you save the library, it will be saved with a reference to a non-existent untitled VI. When you later load that library, the blank VI will be recreated, but the library will report itself as broken because of a missing VI, and the library will have no obvious way to be fixed short of recreating the library from scratch.

Workaround: Open the library file in a text editor. Find an tag where the Name attribute refers to an untitled VI. Delete that tag (everything from the to the ) and save the library file. This fixes the corrupt part of the library.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 08/30/2010
246375

Return
Unexplained broken wire when local variable of Chart control interacts with uninitialized shift registers
A Chart changes its type to match the type of the wire connected to its FPTerminal. If you create a local variable of the Chart, that local variable will also change its type to match the FPTerminal. If both the local variable and the FPTerminal are inside the same loop AND the wire going into the FPTerminal is coming from an uninitialized shift register, then there are rare situations in LabVIEW 2010 where the wire going into the local variable will end up broken and complaining about incompatible types even though the types on both ends of the wire are identical. This bug does not exist in LV 2009 or earlier.

Workaround: Set the type going into the FPTerminal explicitly instead of relying upon the type calculated by the uninitialized shift register. Methods for doing this will vary greatly between diagrams.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 08/30/2010
246540

Return
NI-Auth permissions get reset in build specification
When setting NI-Auth permissions for a directory in a Web Service Build Specification the permissions do not persist between closing and opening the Web Service Build Specification

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 08/30/2010
246593

Return
Power of X and Y-th Root of X returns incorrect result when using single precision numbers
When using the Power of X or Y-th Root of X functions with single precision number the output will be incorrect. These functions will always return a value of one if X is positive and NaN if X is negative.

Workaround: This has been fixed in the LabVIEW 2010 f2 Patch

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 08/30/2010
249370

Return
In LabVIEW 2010 on a Mac, you cannot save VIs with the .vit and .ctt file extensions
(Mac OS Only) In LabVIEW 2010 on a Mac, you cannot save your VIs as .vits or .ctts. (Saving to .ctl works)

Workaround: Rename the VI on disk unless the VI or Control is a member of a library. If it is a member of a library, move it out of the library (in the project tree) first, then save it, remove it from the project, change its name on disk, and finally move it back into the library.

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 09/21/2010
176848

Return
Picture Control Stops Updating After Setting Properties to Default.
Once the picture control's values have reinitialized to default by selecting Data Operations»Reinitialize to Default or programmatically using the method Reinitialize to Default, the mouse position property node stops updating.

Workaround: Replace the picture control with a new one from the palette. 

Reported Version: 8.6.1  Resolved Version: N/A  Added: 09/24/2010
244148

Return
Certain Trigonometric Functions Return Incorrect Results in LabVIEW 2010 when Using Extended Precision Inputs
In LabVIEW 2010 certain trigonometric functions will return incorrect results when using extended precision inputs to the functions. The affected functions are sec(x), csc(x), cot(x), acos(x), asec(x), sinc(x)

Workaround: This has been fixed in the LabVIEW 2010 f2 Patch

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 09/27/2010
247384

Return
TestStand Error -18004 When Attempting to Configure or Execute LabVIEW 2010 VIs While Debugging My LabVIEW User Interface in LabVIEW 2010
If you are using TestStand 4.x with LabVIEW 2010, and have installed the LabVIEW 2010 Compatibility patch for your version of TestStand as suggested by KnowledgeBase 5BRA2TXU: NI TestStand 4.x patches required for compatibility with LabVIEW 2010 and later. When debugging your TestStand User Interface in the LabVIEW Development System, if you select Specify Module for a LabVIEW step, or if you execute a LabVIEW step, you will receive Error -18004 .

Workaround: This has been fixed in the LabVIEW 2010 f2 Patch

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 09/27/2010
136677

Return
Remote panels do not work if Internet Explorer is embedded in an ActiveX or .NET Container
If a remote panel is built in LabVIEW 8.6 and embedded in an ActiveX or .NET Container in a LabVIEW 8.6 VI it will not display correctly

Workaround: Use a remote subpanel. This is actually the recommended way to accomplish this task

Reported Version: 8.6  Resolved Version: N/A  Added: 10/01/2010
187247

Return
ActiveX functions return error 1 if using a 64-bit integer
LabVIEW invoke nodes can be configured to invoke functions containing 64-bit integers parameters, but when executing the invoke node it always fails with error 1.

Workaround: N/A

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 10/01/2010
192280

Return
Open UFF58 VI will cause a hang if built into an application
If you use the UFF58 functions and build them into an application the called DLL does not get pulled into the application.

Workaround: Create an always included VI that specifically uses the UFF58 dll in a Call Library Function Node. This will cause application builder to pull in the dll.

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 10/01/2010
196607

Return
DTbl Replace Subset VI behavior change between LabVIEW 8.6.1 and 2009
The start input indexes from the replacement data instead of the existing data

Workaround: Set the index of data to replace from 0

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 10/01/2010
196742

Return
Load STL Geometry VI cannot load binary STL files

Workaround: Use a different type of STL file.

Reported Version: 2009 32-bit  Resolved Version: 2013  Added: 10/01/2010
226840

Return
Formula VI does not execute pow(x,y) function

Workaround: Use the formula node to use the pow(x,y) function. If you need to change this programmatically, use the Power of X function in G code.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 10/01/2010
236377

Return
Dropping XControl from public library breaks XControl
When adding an X control from a public library into the controls palette, it become broken when dropped down to the front panel from the controls palette.

Workaround: Include a merge VI in the functions palette

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 10/01/2010
243625

Return
Nested libraries cause unnecessary dirty dot.
If you have nested libraries and load the child library the higher level libraries will open with a dirty dot. This applies to classes as well

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 10/01/2010
246966

Return
Write to Text File output changed from LabVIEW 2009 to 2010 if the user selects cancel in the file dialog
In LabVIEW 2009, canceling the file dialog when you leave the Write to Text File function's 'path' input unwired returns Error 43, "Operation cancelled by user," and the 'cancelled' output is TRUE. In LabVIEW 2010, canceling the file dialog when you leave the Write to Text File function's 'path' input unwired returns various undefined errors, and the 'cancelled' output is always FALSE.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 10/01/2010
247628

Return
Reading a TDMS file written using DAQmx Configure Logging VI may result in an out of memory error.
If a TDMS file was written using the DAQmx Configure Logging VI, reading channels from the TDMS file without specifying the count input of the TDMS Read functions may result in LabVIEW trying to load the entire file into memory. Depending on the DAQmx scaling used during logging, the memory needed for scaled data values might be a multiple of the actual file size. If the available memory is not sufficient, LabVIEW returns an error about how memory is full.

Workaround: This has been fixed in the LabVIEW 2010 f2 Patch

Reported Version: 2010 64-bit  Resolved Version: 2010 SP1 64-bit  Added: 10/01/2010
248914

Return
Changing the order of controls or deleting controls in a type def cluster can change references
When you create a reference for a control in a type defined cluster LabVIEW uses the cluster order to determine what control the reference is referring to. Say you have a type defined cluster with elements A, B, C and D with cluster order 1,2,3 and 4 respectively. On the block diagram of a VI you have control references to each of the controls. If you open the type def and delete control C the block diagram of the VI will only contain 3 references. Moreover, the reference that used to be for control C will now reference control D. This is because the control is based on cluster order

Workaround: N/A

Reported Version: 7.1.1  Resolved Version: N/A  Added: 10/01/2010
248965

Return
Deploying an executable that uses SSL with the HTTP Client API will error out
To use SSL with the HTTP Client API you have to purchase an internet toolkit license. This issue with this is if you build a LabVIEW application (EXE) that uses this functionality the user will receive an error 1380

Workaround: Manually install and activate internet toolkit license file on the deployment machine

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 10/01/2010
285210

Return
Read from Measurement File Express VI can read incorrect data
If you use a Write to Measurement File Express VI to write an LVM file, the data can be misinterpreted from the Read from Measurement File Express VI if the LVM file has headers. The file is correctly written; however, it is just read incorrectly.

Workaround: Don't write headers in the LVM file

Reported Version: 2009 32-bit  Resolved Version: 2012 32-bit  Added: 10/01/2010
322914

Return
Formula VI does not execute pow(x,y) function

Workaround: Use the formula node to use the pow(x,y) function. If you need to change this programmatically, use the Power of X function in G code.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 10/01/2010
256141

Return
Windows 7 often shows "(Not Responding)" and will bring other windows to the front during expensive operations
If Windows 7 if a window is unresponsive to user input (e.g. mouse clicks) for five seconds it will ghost the window and display "(Not Responding)".Some operations in LabVIEW run in the UI thread. This is to prevent different operations from happening in parallel (e.g. compiling, edit operations, saving, drawing, etc.). Because large block diagrams can take longer than five seconds to compile or run clean up on Windows can tag LabVIEW as Not Responding.In some cases the ghosted window can move behind the other open windows when it finishes it task.

Workaround: Wait until the expensive task as finished before trying to interact with the window.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 10/28/2010
235775

Return
LabVIEW crashes in assembly deployment if lkads.exe is not running on Vista/Windows 7
If you try to connect to a target running the controller engine without the National Instruments PSP Server Locator service (lkads.exe) running, LabVIEW will crash.

Workaround: Start the service.

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 10/29/2010
242600

Return
A search dialog can appear when building a source distribution where the main destination is a library
Building a source distribution with the following options set will display a dialog searching for unused VIs in libraries in the original project:- Remove unused library members- Main destination is a library

Workaround: N/A

Reported Version: 8.5.1  Resolved Version: 2011 32-bit  Added: 10/29/2010
248065

Return
Application Builder fails with Error 74 with upgraded .NET and a dll call
It is possible that upgraded .NET code will fail to build if the build also contains a dll. This is caused by the linker information that stores where the .NET nodes find their actual assembly.

Workaround: Completely delete the .NET code from your program (whole project). Save the project, close and reopen it. Add the nodes back to your program. Do NOT copy and paste the nodes from other VIs.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 10/29/2010
248421

Return
Bitshift does not work correctly in Expression Nodes and Formula Nodes with a data type smaller than I32

Workaround: N/A

Reported Version: 8.5.1  Resolved Version: N/A  Added: 10/29/2010
250119

Return
LabVIEW crashes if you delete a compound arithmetic primitive with a breakpoint

Workaround: Remove breakpoint first, then delete.

Reported Version: 8.6.1  Resolved Version: 2010 SP1 32-bit  Added: 10/29/2010
251094

Return
HTTP Post Reports Error 42 When Executing a FSWS Download with a 1MB File

Workaround: Ignore the error 42

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 10/29/2010
251229

Return
Adjusting X-Scale Multiplier Property Affects Graph Annotations
When adding annotations to a graph they can appear on the Y-axis instead of above the data.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 10/29/2010
254821

Return
LabVIEW built executable with network streams won't exit process
LabVIEW built executables that load the the network streams dll will not dispose of it properly when finished. The executable's process will remain in the task manager

Workaround: Manually kill the process after completion.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 10/29/2010
255627

Return
Remote Panels not working in LV 2010 built executables
Remote panels work with regular VIs but when they are built into an executable they will not work.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 10/29/2010
IDKnown Issue
300558

Return
LabVIEW built executable with network streams won't exit process
LabVIEW built executables that load the the network streams dll will not dispose of it properly when finished. The executable's process will remain in the task manager

Workaround: Manually kill the process after completion.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 10/29/2010
300592

Return
LabVIEW built executable with network streams won't exit process
LabVIEW built executables that load the the network streams dll will not dispose of it properly when finished. The executable's process will remain in the task manager

Workaround: Manually kill the process after completion.

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 10/29/2010
250588

Return
Warning Generated in a Method or Property of an XControl Appears as an Error in the Top Level VI
If you create a method or a property in an Xcontrol in which you have implemented code to generate a warning it is transformed into an error in the calling VI.

Workaround: In the VI look for specific error and transform back to a warning

Reported Version: 8.5.1  Resolved Version: N/A  Added: 11/02/2010
246263

Return
LabVIEW Class Properties don't output or produce invalid input in LabVIEW, crash or produce invalid output in built applications
Some VIs that use Dynamic Dispatch LabVIEW Class Properties may crash or produce invalid data. This is caused by an incorrect behavior in associating property nodes with the properties represented in the LabVIEW Classes.

Workaround: In some cases changing the property accessor's class input and output terminals to static and then back to dynamic dispatch will help. In other cases there is no work around.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 11/04/2010
221992

Return
LabVIEW Constructor node cannot load dlls written in .net 4.0
LabVIEW supports the .NET Framework 2.0. It does not support the new features of .NET past 2.0. Many applications built with the .NET Framework 3.0 or 3.5 would still use mscorlib 2.0 which hadn't changed versions since .NET 2.0. With Visual Studio 2010 and .NET 4.0, Microsoft replaced mscorlib 2.0 with mscorlib 4.0. Because of this LabVIEW cannot load assemblies compile for the .NET Framework 4.0

Workaround: See KnowledgeBase 592CE60U

Reported Version: 8.5.1  Resolved Version: 2011 32-bit  Added: 11/08/2010
292464

Return
The function GaussHG returns NaN for X values less than 0.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 11/18/2010
249566

Return
LabVIEW 2010 crashes with fpsane.cpp line 442 when "Modifications:Front Panel (or Block Diagram) Mods Bitset" property is used
LabVIEW 2010 will crash, if you use the VI Modifications Bitset property node with a case structure (the output of the property node wired to the case selector) and then change the property node to be Front Panel Mods Bitset (or Block Diagram Mods Bitset). LabVIEW will crash if you try to save the VI or if you select the broken run arrow. Previously 276039

Workaround: Delete the existing case structure and replace it with a new one from the palette.

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 11/24/2010
244158

Return
LabVIEW 2010 crashes with image2.cpp line 250 when opening a VI with a constant set to 'View As Icon'
If you create a (strict) type definition of a cluster and put a constant which is linked to this typedef on the Block Diagram with the View As Icon set, LabVIEW 2010 will crash if the typedef on disk is deleted and the VI containing the constant is opened again. You will get a Fatal Internal Error: image2.cpp line 250

Workaround: Do not use the 'View As Icon' option for constants if you intended to delete the typedef ctl file

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 11/29/2010
276334

Return
On VxWorks targets, the TDMS Defragment VI shows Error 6 and deletes the file it is operating on in the U:\ drive
TDMS Defragment VI shows Error 6 and deletes the file it is operating on when told to operate on a TDMS file that is located on the U:\ drive of a VxWorks Real-Time target. (U:\ drive is a USB drive)

Workaround: Use the TDMS Defragment VI on a TDMS file that is located on the C:\ drive. Then move the defragmented file to the U:\ drive.ORA copy of the degramented TDMS file from the U:\ drive can be found in the temp directory (for cRIO it's c:\temp). Note: The temp file gets overwritten every time the TDMS Deframent VI is used, so only the latest file is available in the temp folder

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 12/02/2010
258485

Return
FTP VIs do not close session if there is an error
If any of the high level FTP Functions such as FTP Get File.vi and FTP Get Buffer.vi experiences an error within the VI, the FTP session stays open and the user remains logged into the FTP server. This seems to be because the FTP Close.vi within it does not execute if there is an error.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 12/06/2010
277392

Return
Typecast of object with different binary size may crash LabVIEW
If you attempt to typecast a data type into a new data type with a different size, especially if it is smaller, you may crash LabVIEW at that time, or later, when you attempt to use the new item.

Workaround: Do not typecast using inputs and outputs of different sizes.

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 12/08/2010
255466

Return
Shared variable moved from a project directly to a tab control is not added to the active page.

Workaround: After dragging the variable to the tab control. Reselect it and drag it slightly until the dotted lines appear around the tab control page and then drop it. The shadow is then removed because the variable has been added to the active page.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 12/15/2010
256559

Return
Including .vi in web method name and using "?" as a query separator causes app web server to crash

Workaround: Do not ever use .vi in the web method name in the URL

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 12/15/2010
256928

Return
LabVIEW crashes when closing a VI reference to a reentrant VI with shared clones when using TestStand
LabVIEW crashes when a VI reference to a reentrant VI which shares clones between instances in the following scenario:TestStand's VI deployment tool is used to package VIs and create packed project libraries. In order to add the VIs to a packed library the tool will open references to all the VIs, add them to a library, save the library and all the files, then it adds the library to the project and closes the VI references. When the reference to the reentrant VI is closed LabVIEW crashes.

Workaround: N/A

Reported Version: 2010  Resolved Version: 2010 SP1 32-bit  Added: 12/15/2010
257197

Return
Error Constant erroneously added to Variant to Data

Workaround: Fix the diagram after upgrading.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 12/15/2010
258758

Return
Setting digits of precision in Distributed System Manager has no effect.

Workaround: N/A

Reported Version: 2010  Resolved Version: 2012 32-bit  Added: 12/15/2010
276831

Return
Output of zero generated from the multiply node with certain DAQmx properties and VIs when using highlight execution

Workaround: Use indicators for debuging

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 12/15/2010
277049

Return
Changing a missing Type Definition Control to a constant crashes LabVIEW

Workaround: Disconnect from Type Def before changing to constant.

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 12/15/2010
277283

Return
When creating a VI Snippet with code that contains a tab control, the snippet does not properly save the contents of each tab.

Workaround: N/A

Reported Version: 2009 32-bit  Resolved Version: 2014  Added: 12/15/2010
245609

Return
Swapping Connector Pane terminals loses Required status
If you use the switcheroo tool to switch connector pane terminals this will re-categorize the terminals as Recommended. Previously tracked as CAR 277047

Workaround: Set the status of the terminals after switching.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 12/31/2010
246681

Return
lvwsdsc not generated correctly unless your VI is in your project directory
If your web service VI is in a subdirectory under your project, then the lvwsdsc file does not generate the sections under each . This causes the Web UI Builder to not generate these as inputs to the generated wrapper VIs.

Workaround: Use the 8.x file layout

Reported Version: 2010 64-bit  Resolved Version: 2010 SP1 32-bit  Added: 12/31/2010
255982

Return
Child Class Property Node does not output until deleting and rewiring any part of the VI
This issue pertains to Object-Oriented Programming in LabVIEW. Essentially upon creating a Parent class and Child class, we are unable to read the child class properties in the main VI through property nodes unless we have changed the VI recently (i.e. unwire & rewire).

Workaround: The workaround for this issue is to use subVIs created from 'VI for Dynamic Dispatch Template.' Within the subVIs you are able to unbundle and bundle the object.

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 12/31/2010
257275

Return
Format Into String does not work with the %d format for numbers larger than I32
The Format Into String VI does not correctly format numbers outside the 32-bit integer (I32) range when using the '%d' format. When the number is outside the I32 range, the resulting string displays either -2147483648 or 2147483647 depending on if the number is negative or positive.

Workaround: Use %.0f instead of %d as the format string.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 12/31/2010
276928

Return
Opening a TDMS file with LabVIEW 2010 can produce error -2503
More information and a workaround can be found in this KnowledgeBase

Workaround: See KB

Reported Version: 2010 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 12/31/2010
278559

Return
Nested classes in a packed project library breaks a VxWorks VI.
When building a packed project library that includes nested classes for a VxWorks target, the VIs in the built library are broken. However if you build for a PharLap or Windows target, there aren't any issues.

Workaround: Use a debuggable packed library

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 12/31/2010
279298

Return
Deploying a VI with OO Accessors can cause internal error 1394
Certain LabVIEW classes can cause deployment errors if they contain accessor methods that are available as property nodes. The possible errors that occur are internal error 1494 or an RTEmbEditor.cpp DWarn at line 105.

Workaround: Recompiling the VI may offer a temporary solution but replacing the property nodes with regular accessor methods should fix the problem.

Reported Version: 2010  Resolved Version: 2010 SP1 32-bit  Added: 12/31/2010
254317

Return
LabVIEW can crash when deleting broken wires.
LabVIEW will sometimes crash when deleting sections of block diagram code that contain broken wires.

Workaround: Use Ctrl+B to delete broken wires

Reported Version: 2010  Resolved Version: 2010 SP1 32-bit  Added: 01/05/2011
192804

Return
Error 91 occurred at the Variant To Data node
Variant To Data sometimes throws an error 91 when running in a built executable in LV 2009"Error 91 occurred at ...Possible reason(s):LabVIEW: The data type of the variant is not compatible with the data type wired to the type input."

Workaround: 1) Update the variant type by generating a new one. (In an empty VI wire the typedef into the "data to variant" prim and run the VI. Then create a constant from the indicator and use this constant as the new type for the variant.)OR2) Use a Flatten Variant to String and then an Unflatten from String (not the variant version). If you wire in the control you're trying to extract from the variant, it will work like a charm.

Reported Version: 2009 32-bit  Resolved Version: 2012 32-bit  Added: 02/18/2011
236193

Return
Crash with invalid input (o or negative values) of "samples per channel" when misusing TDMS Set Channel Information
There are some situations if you set the value of "samples per channel" of TDMS Set Channel Information as 0 or negative values (invalid values), which could cause a crash.

Workaround: Avoid using 0 or negative values as "samples per channel".

Reported Version: 2010  Resolved Version: 2010 CVI  Added: 02/18/2011
245148

Return
Class Properties dialog sometimes throws timeout error 123 when opening and must be restarted
In LV 2010, there appears to be a timing race condition in the Class Properties dialog for LabVIEW classes. Every once in a while if you try to launch the dialog, the dialog will throw an error dialog reporting error 123 that the dialog has timed out while trying to launch. After you dismiss the dialog, you may see a secondary error dialog. Once you dismiss that, you can relaunch the Class Properties dialog and will generally succeed. There is no danger to your class and no corruption to you class file has occurred. It is solely a bug in trying to launch the dialog.

Workaround: Hit Continue or OK button to dismiss all error dialogs that come up then retry opening the Class Properties dialog.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 02/18/2011
251105

Return
S&V XControls built as Remote Panel crashes LabVIEW.
Remote panels do not reliably support the Sound and Vibration XControls.

Workaround: Use another mechanism for remote viewing.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 02/18/2011
251951

Return
HTTP Client VI calculates wrong dll path when built into a built app on LV RT
If you build using the http client api Open Handle.vi into a startup application it will return error 7.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 02/18/2011
276766

Return
Flat Sequence Structure leak GDI Objects, wasting memory and eventually crashing LabVIEW
This leak occurs when the Flat Sequence Structure is moved. Using the keyboard create many different moves of a small distance. Using the mouse creates one move of a larger difference.

Workaround: Use data flow and case structures to force execution order

Reported Version: 2009 32-bit  Resolved Version: 2010 SP1 32-bit  Added: 02/18/2011
278029

Return
Changing an case selector from I64 to U32 can cause a corruption
If you originally have an I64 wired to a case selector terminal and then change it to U32 the case structure will become corrupt and will eventually thrown an insane object error.

Workaround: If the real need for change is the source and not the case structure itself, drop a conversion bullet in front of the Case structure so the input to the case structure is not changed.

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 02/18/2011
281124

Return
Nested diagram disable structures can cause LabVIEW to no compile.
If you place a diagram disable structure with both cases disabled on your block diagram, you get an broken run arrow and an error from LabVIEW saying "Diagram disable structure has no active diagram".However, If you place a diagram disable structure with both cases disabled inside the disable case of another diagram disable structure you don't get a broken run arrow. When you try to run the VI you get the error message, "LabVIEW Needs more memory to compile".

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 02/18/2011
256238

Return
Last iteration of parallel for loop may not execute in parallel when it has non-indexing output tunnels
The last iteration of a parallel for loop may execute serially after all of the other iterations are finished when the loop has at least one non-indexing output tunnel. This can be particularly noticeable when the loop executes a small number of iterations and each iteration performs a large amount of work.

Workaround: Remove all non-indexing output tunnels from the loop.

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 03/21/2011
289842

Return
Get Variant Attribute VI returns wrong value if attribute not found
The default value that's returned by the Get Variant Attribute VI is not blank when nothing is wired to the default value terminal. The Get Variant Attribute instead seems to return the last/previous value it returned as the default value.

Workaround: Use the Found? output and logic to return a blank variant if necessary

Reported Version: 8.6.1  Resolved Version: N/A  Added: 03/21/2011
238713

Return
3D Picture Controls can display transparently or crash LabVIEW on certain graphics cards
The 3D Picture Control is built on a OpenSceneGraph which uses OpenGL. Several reports of the 3D picture control crashing LabVIEW have been reported. In almost all cases it was an Intel integrated graphics card involved. This crash is caused by an incompatibility of the graphics hardware.Note: Many of the 3D Graphs use the 3D Picture Control

Workaround: There have been several things that have worked for users:
  • Update the video driver
  • Turn on/off hardware acceleration
  • Turn on Aero in Windows 7
  • Turn off Aero in Windows 7


Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 04/20/2011
255617

Return
Error 1502 can occur if dependencies are placed in non executing case structures
In previous versions of LabVIEW you could place VIs in a case structure with a constant wired the the case selector. This would load the VIs at runtime. If you have this pattern and attempt to build an executable you could receive error 1502

Workaround: Don't use unreachable code

Reported Version: 8.6.1  Resolved Version: 2014  Added: 04/20/2011
283943

Return
Many VI Server methods work across contexts and use variants, which can crash LabVIEW when provided with context sensitive data (such as LabVIEW Classes).
Writing a VI which passes or returns variants with a VI Server method or property to interact with a VI open in another context can crash LabVIEW when using context sensitive data (such as LabVIEW Classes).

Workaround: Make sure that any interaction with context sensitive data is performed by a VI loaded in the same context as the target. If you need to give commands to a target in another context, you may need to load a helper VI in the target's context and use simpler datatypes to instruct the helper VI how to interact with the target.

Reported Version: 8.6.1  Resolved Version: 2011 32-bit  Added: 04/20/2011
284688

Return
Japanese LabVIEW 2010 SP1 fails to launch when a third party toolkit is installed.
If a third party toolkit using SoftKey licensing is installed on the system, Japanese LabVIEW 2010 SP1 will fail to launch.

Workaround: Apply the LabVIEW 2010 SP1 f1 Patch.

Reported Version: 2010  Resolved Version: 2011 32-bit  Added: 04/20/2011
284936

Return
Breaking one Override VI in LVOOP shows all siblings as broken but does not explain why
When using OOP in LabVIEW, breaking the connector pane of a child class Override VI will make all of its sibling override VI's appear broken even though they are not broken. Hitting run on the broken Run Arrow of any child class Override VI will list all of the child class VIs in the list of "Items with Errors", but none of them will have an error associated with it except for the broken ones.

Workaround: Use the red X in the errors window to find the actual broken VI

Reported Version: 8.6.1  Resolved Version: N/A  Added: 04/20/2011
289559

Return
Dynamically launching reentrant VIs is slower and requires more memory.
If you dynamically launch a reentrant VI it will take approximately 2x more memory and be 2x slower than in LabVIEW 2009.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 04/20/2011
186808

Return
Shared Variable library on PC is undeployed if the a V in the same project is programmatically deployed to a Real-Time target
When programmatically deploying a VI to a Real-Time target the Shared Variable library residing in the same project as the deployed VI will be undeployed.

Workaround: Programmatically deploy the shared variable library on the PC after deploying the VI to the real-time controller.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 07/20/2011
284289

Return
Source distributions with block diagrams removed prevents the use of static Shared Variable nodes.
Source distributions that include static Shared Variable nodes with block diagrams removed will return the following error at run-time, "VI has a bad connection to or cannot find a subVI or external routine."

Workaround: Use the Programmatic Shared Variable API or do not remove the block diagrams.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 07/20/2011
306205

Return
Error 1003 when building an executable with OpenTrace.vi within a LabVIEW Class
If you are building a stand alone LabVIEW executable that has the polymorphic OpenTrace.vi within a LabVIEW class error 1003 will occur during the build.

Workaround: Call the individual instance of the OpenTrace VI (Open Trace (Numeric), Open Trace (Logical), etc) instead of the polymorphic VI. These VIs can be found at C:\Program Files\National Instruments\LabVIEW 2011\vi.lib\lvdsc\historical.

Reported Version: 2010  Resolved Version: 2012 32-bit  Added: 07/20/2011
252270

Return
Stacked chart will not update all points if Digital Display is visible and on top of the chart

Workaround: Move all Digital Displays off of the graph itself

Reported Version: 2010 32-bit  Resolved Version: 2013  Added: 08/02/2011
279373

Return
SMTP has been updated to use port 587; LabVIEW makes use of legacy port 25
The SMTP has been updated to use port 587 instead of port 25. LabVIEW still makes use of port 25 with its SMTP VIs.

Workaround: Open any SMTP VI, and find the SMTP_CreateSession.vi. Open that VI, you will find a numeric constant on the block diagram that is set to 25.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/02/2011
282737

Return
Applications with Chinese characters in the executable name will throw fatal error on English Windows 7

Workaround: Use a different name for the executable.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/02/2011
283709

Return
Logos Sockets should broadcast on all available NICs
The behavior of a UDP broadcast on a machine with multiple network adapters has changed between Windows XP and Windows 7. It's not clear at the moment whether this change was introduced in Windows 7 or Windows Vista. In Windows XP, if a UDP socket is not bound to a specific NIC, a broadcast packet would be sent on all available adapters. In Windows 7, only one adapter is used (the one with the lowest numeric IP address, which is essentially random). This link gives further details:http://serverfault.com/questions/72112/how-to-fix-the-global-broadcast-address-255-255-255-255-behavior-on-windows

Workaround: Setting the "ServiceBindTo" INI token to the MAC of the primary NIC will guarantee that broadcasts happen on that NIC. However, this will not allow broadcasting on multiple subnets, and it will make the chosen NIC the only NIC which can perform Logos Sockets communication. New Logos XT communication will be unaffected, but this could be important for legacy apps. Note, however, that Logos Sockets can only ever use a single NIC, so any legacy app running on a mult-NIC machine has likely already bound all Logos communication to the appropriate NIC.

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 08/02/2011
IDKnown Issue
284802

Return
Programmatically enabling shared variable alarm leads to deployment error and mismatch between shared variable properties and the multivariable editor.
When programmatically generating shared variables and enabling specific alarms (HiHi, LoLo, etc.), the shared variable properties do not match the multivariable editor

Workaround: Programmatically generate the shared variables and manually enable the specific alarms using the multivariable editor.

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 08/02/2011
292599

Return
Using Array Selection Size[] or Selection Start[] Properties can crash LabVIEW 64-bit

Workaround: N/A

Reported Version: 2010 64-bit  Resolved Version: 2011 64-bit  Added: 08/02/2011
293342

Return
Preallocated reentrant LabVIEW Class Property accessors cause LabVIEW to crash
When you change a LabVIEW Class Property accessor to preallocated reentrant, LabVIEW may crash. The crash will be soon after making the change. The crash only occurs when there is an open VI which uses that property more than once.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 08/02/2011
294285

Return
Type Defined Shared Variable not found in Executable
When a VI is made with the following conditions:1) Uses a Shared Variable attached to a type definition2) The type defined control (attached to the shared variable) is not in the main project directory (ie, it is in a different folder)3) The VI uses dynamic data (or waveform to dynamic data function)A created executable seems to not include the *.ctl file defining the shared variable type. This missing type definition causes the run time engine, when starting the executable, to search for and (if the control is not located in the searched directories) fail to find the *.ctl file. If the location of the *.ctl file is specified, the executable runs without issues.

Workaround: Disconnect from Type Def during the build.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/02/2011
294981

Return
Creating a copy of a class and adding it to the current project from the Save As dialog may crash LabVIEW
A bug exists in LabVIEW which may cause it to crash when using "Save As" to create a copy of a class and add it to the current project at the same time. If you have a class that has LabVIEW class properties and that class contains a VI which uses those properties, LabVIEW may crash when adding that class to the project. This only occurs when you use the check box in the Save As Dialog that says "Add copy to XYZ.lvproj"

Workaround: Don't add the class to the project from the Save As dialog. Once you've saved a copy, add it to the project separately.

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 08/02/2011
305928

Return
Saving a VI that has separated compiled code will leak memory
When you save a VI that has Separate compiled code from source file selected it will leak memory the same size as the source VI.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 SP1 32-bit  Added: 08/02/2011
308464

Return
LabVIEW cannot build some large applications because it fills the image table.
LabVIEW cannot build some large applications. If you try to build a large application it will fail. An internal warning is thrown during the build stating that the image table has been filled.

Workaround: This issue has been fixed in the LabVIEW 2011 f2 Patch. 

Reported Version: 8.0.1  Resolved Version: 2011 SP1 32-bit  Added: 08/02/2011
306797

Return
Cannot create indicator/control/constant for refnum datatypes from XML property and invoke nodes
LabVIEW for Linux cannot create indicators, controls, or constants for refnum datatypes from the XML Parser property or invoke nodes

Workaround: N/A

Reported Version: 8.6.1  Resolved Version: 2011 SP1 32-bit  Added: 08/30/2011
179603

Return
Call Parent Node input must be the same as dynamic dispatch terminal.
When using the call parent node in a VI with dynamic dispatch terminals, the data must flow from the terminal to the Call Parent Node. If not the VI should break. In LabVIEW 2010 and previous this doesn't break. However this will break in LabVIEW 2011 with the error message: "The data from the dynamic input must flow to the Call Parent Node; however, you can modify the data along the way. In this error, there is no wire path that leads from the dynamic input front panel terminal to the dynamic input of the Call Parent Node. Without such data flow, a child class may violate the functionality contract established by its parent class."

Workaround: Turn off the output's "Dynamic Dispatch Output" option.

Reported Version: 8.2  Resolved Version: 2011 32-bit  Added: 09/22/2011
112702

Return
Cannot read file that shows up as zero bytes.
Linux, Unix and Macs can have files that show up on disk as zero bytes but actually have data that can be read. If you use a Read Binary File primitive on these files you will return an empty string.

Workaround: Read a large number of bytes and handle the end of file error that you will receive.

Reported Version: 8.6  Resolved Version: N/A  Added: 10/20/2011
187412

Return
Custom RTM will incorrectly link to the source location when built into an executable
If you have a custom Run-Time Menu you can include it in an executable. When we build the executable we incorrectly link to the original location of the RTM file instead of the one being brought into the build.

Workaround: Save the original RTM files in a location that you can distribute. For example if you save them in the "Data" directory that is next to where the executable will be saved this will work and create a package that isn't terrible to distribute.

Reported Version: 2009  Resolved Version: 2012 32-bit  Added: 11/02/2011
250532

Return
ConnectorPane.cpp can cause a VI to be unable to load
This internal warning can cause a VI to have a corrupt connector pane. If this occurs you will get Error Code 3: Cannot load front panel, when you attempt to open the VI.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2011 SP1 32-bit  Added: 11/09/2011
321876

Return
VI Password Protection can be defeated
It is possible for an attacker to defeat a VI’s password protection. Refer to KB: Security of LabVIEW VI Password Protection vs. Removing VI Block Diagrams. This issue will be marked as fixed when the information is in the LabVIEW Help.

Workaround: Use Remove Block Diagram for maximum protection.

Reported Version: 8.5.1  Resolved Version: 2012 32-bit  Added: 11/09/2011
233061
4AQA5L00

Return
LabVIEW crashes after working with Simulation Subsystem using a LabVIEW Class
Sometimes LabVIEW will crash after working with a Simulation Subsystems that has a LabVIEW Class as one of its controls or indicators on its connector pane. Usually it is only a problem when working with the Subsystem's caller within a LabVIEW Project. The crash will occur after closing the project, while returning to the initial LabVIEW window.

Workaround: Save all work before closing the LabVIEW Project when using LabVIEW Simulation and Classes together.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 11/10/2011
327431

Return
Import WebService Tool doesn't work for HTTPS protocol
Web Services cannot be imported if they are on an HTTPS server. The same web service can be imported if it is on an HTTP server

Workaround: Use an HTTP server

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 12/02/2011
338840

Return
Shortcut Menu Activation Interferes with Independent Autoscale Y Settings in Waveform Chart or Graph with Multiple Plots
The Autoscale Y setting is not remembered for each plot when a waveform chart that contains multiple plots also contains a Shortcut Menu Activation as a Dynamic Event Registration. By changing the setting of one axis, it becomes altered on another.

Workaround: None

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 02/17/2012
186525

Return
'visarc' file included in source distribution even when excluding vi.lib
If you are using VISA and build a source distribution you get a copy of the visarc file with your source distribution and your VIs link to that copy.

Workaround: 1. Delete the visarc file made by the build2. Add visarc to the project under My Computer. In the build spec, add the file as Always Excluded.

Reported Version: 8.6.1  Resolved Version: 2012 32-bit  Added: 04/26/2012
333279

Return
Calling the System Exec VI after calling the Pipe VI in LabVIEW for Linux will Hang LabVIEW.

Workaround: Do not call the System Exec VI after calling the Pipe VI.

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 04/26/2012
239631

Return
Memory Growth with TDMS Write
With the standard TDMS API, when TDMS Write VIs are executed the API will build a cache in memory. This may present as a memory leak, as this memory is only cleared in specific situations.

Workaround: See KnowledgeBase 5WQD51YS: Memory Growth with TDMS Write for more information.

Reported Version: 2009  Resolved Version: N/A  Added: 04/27/2012
303503

Return
When a LVM file is read by the Read from Measurement File Express VI, the Y Unit attribute is ignored.

Workaround: N/A

Reported Version: 2010 32-bit  Resolved Version: 2013  Added: 05/01/2012
191423

Return
LabVIEW does not execute properly when certain .NET properties are changed on the .NET RichTextBox control
The HideSelection, WordWrap, and ScrollBars .NET RichTextBox properties don't execute correctly, and cause display update issues on some versions of LabVIEW.

Workaround: N/A

Reported Version: 8.6.1  Resolved Version: 2011 32-bit  Added: 05/14/2012
286917

Return
DSC Periodic I/O Servers run as SYSTEM and creates a security vulnerability
Period I/O server runs within the Shared Variable Engines (tagsrv.exe) in the SYSTEM security context. Any user on the machine (excluding guests), regardless of security level (administrator, user, power user, etc...) can deploy a Periodic I/O server to be run by the Shared Variable Engine. This makes it possible for a non-priviledged user to run LabVIEW code at a higher permission level than they are allowed. This is commonly know as a priviledge escalation vulnerability. (This does not apply to guest users as they seem to be unable to deploy LabVIEW Web services)This is dangerous as the Application Web Server is automatically installed and enabled (at least in LabVIEW Beta 2), allowing any user on the machine to use this vulnerability to execute code in the SYSTEM security context without having to enable or modify anything. This invalidates Windows user security.

Workaround: 1. Open the Service Control Manager (in Vista and Win 7 simply type "Services" in the "Search for Programs and Files" box in the start menu.2. In the service control manager, find "National Instruments Variable Engine" 3. Right click and select "Properties" in the popup menu.4. Click on the tab labeled "Log On"5. In the dialog, click on the radio button labeled "This account:"6. Select a user account on your machine or domain that does not have administrator privileges on the machine itself.7. Click OK8. Restart the service by right clicking on it in the service control manager again and selecting "Restart".

Reported Version: 2010 32-bit  Resolved Version: 2011 32-bit  Added: 06/12/2012
244551

Return
Editing large strict type definitions can take a long time to update
When large type definitions are updated, all instances in memory require an update. This update can take many minutes for very large type definitions.

Workaround: Use smaller type definitions, or consider using LabVIEW classes to contain your type data.

Reported Version: 7.1.1  Resolved Version: N/A  Added: 07/23/2012
288455

Return
Shared Variable Not Updated When Changing Representation
See KB 56PCQ3RR: Why Is My Shared Variable Not Updated When I Change Representation? for more information.

Workaround: First Undeploy and then Deploy your variables again. A simple Deploy action will not have the required effect.

Reported Version: 8.6.1  Resolved Version: 2011 SP1 32-bit  Added: 07/23/2012
342148

Return
Boolean reference as first item in cluster can causes LabVIEW crash

Workaround: Change the order of the cluster so the boolean is not first.

Reported Version: 8.5.1  Resolved Version: 2013  Added: 07/23/2012
202192

Return
LabVIEW UDP broadcast is inconsistent across different OS's.
If the UDP Open VI has 0.0.0.0 wired to the Net Address terminal, the behavior varies with OS. Windows XP and NI ETS will send on all interfaces, while Windows Vista, Windows 7, VxWorks, and Linux will send on the default interface.

Workaround: N/a

Reported Version: 8.6.1  Resolved Version: N/A  Added: 07/24/2012
218947

Return
IO Variable items under copy-pasted C Series modules lose custom names & configuration
When pasting a cRIO module that has variables under it, the variables are always pasted with the default name and configuration (just as if the module was being created new instead of pasted).

Workaround: Drag or control-drag the module to where you want to paste it.

Reported Version: 8.6  Resolved Version: 2011 32-bit  Added: 08/02/2012
241160

Return
Multiple Instances of a control in an unbundle by name function causes indicators not to update
If you have a cluster wired to an unbundle by name function, and you unbundle the same control twice with the same unbundle by name VI you will sometimes not be able to rebundle the value back into a bundle by name function. The value will not go into the bundle function.

Workaround: Do not use the same control twice on an unbundle by name function.

Reported Version: 2009 32-bit  Resolved Version: 2011 32-bit  Added: 08/02/2012
358049

Return
When a specific VI is opened, and then closed, LabVIEW remains in the task bar, with no windows open.
n/a

Workaround: Do not set a VI to "Open front panel on load" and "Run when opened" at the same time. If you must do this, do not use it as a subVI.

Reported Version: 2010 32-bit  Resolved Version: 2013  Added: 08/02/2012
359369

Return
Application Font change not applied correctly when pasting text
n/a

Workaround: Set the font manually before pasting text.

Reported Version: 2010 32-bit  Resolved Version: 2013  Added: 08/02/2012
239719

Return
Property page doesn't update when Adapt to Source is coerced to off
If you have a FXP constant with Adapt to Entered Data set and make any modifications to the display format, the resulting constant will not be set to adapt. The property page will not reflect this change before it is closed.

Workaround: Always double-check condition of Adapt To Entered Data.

Reported Version: 2010  Resolved Version: N/A  Added: 08/03/2012
245359

Return
Selecting a newer version of a .NET assembly does not reload assembly
Changing a constructor from an old version of a .NET assembly to a newer version at edit time does not cause the new assembly to be loaded and consequently none of the new functionality is available.

Workaround: 1. Remove the old assembly so the .NET Runtime is not able to find it. It will then return the updated version to LabVIEW.2. Load the new assembly in a blank VI before opening your existing VI. This will load the new version into memory prior to you requesting the older version.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/03/2012
257506

Return
Write Binary on array of extended / complex extended with no array size information writes invalid data when set to write native byte ordering.
If you write an extended array with no dimension size in native byte ordering (not big or little endian, but only native ordering) using Write to Binary File, the data is output as 10 byte values instead of 16 byte values.

Workaround: n/a

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 08/03/2012
258226

Return
Remote Panels cannot be viewed by Safari for Mac OS X 10.6 or later
Versions of Safari that shipped with Mac OS X 10.6 or later do not allow plugins that make use of older graphics API's. This means that the Remote Panels plugin needs to be rewritten to work in current versions of Safari.

Workaround: Use Firefox, or connect directly to the Remote Panel from within LabVIEW via the Operate » Connect to Remote Panel… menu.

Reported Version: 2010 32-bit  Resolved Version: 2012 32-bit  Added: 08/03/2012
369142

Return
Front Panels may stop updating with 3+ monitors with Windows Aero enabled
With Windows Aero enabled on a machine with 3 or more monitors the front panel may stop drawing. This issue has been seen in limited cases and is usually after hours of operation. The application itself continues to run. Moving or minimizing the window causes it to start updating again.

Workaround: Disable Windows Aero by selecting a non-Aero theme.

Reported Version: 2010 SP1  Resolved Version: N/A  Added: 09/01/2012
365679

Return
LabVIEW 3D Picture control does not work with certain AMD video card drivers
The 3D Picture control will appear black, or with bands of black, if running on a computer that has an AMD graphics card, and a version of the driver software after Catalyst 11.5.

Workaround: Roll back display drivers to AMD Catalyst Display Drivers version 11.5 or previous. This issue is fixed in LabVIEW 2012 f2.

Reported Version: 8.6.1  Resolved Version: 2012 SP1  Added: 09/14/2012
184689

Return
UI Performance degredation when displaying NaN values on 3D Surface Graph in LabVIEW
N/A

Workaround: N/A

Reported Version: 2009 32-bit  Resolved Version: 2012 SP1  Added: 01/29/2013
257735

Return
Class VIs that call shared variables in a library in an auto-populating folder will not be loaded
If a VI in a class calls a shared variable that is in a library in an auto-populating folder, it will not find the shared variable when the project is loaded

Workaround: Make the folder a snapshot instead of auto-populating and reopen the project

Reported Version: 8.6.1  Resolved Version: N/A  Added: 02/01/2013
367445

Return
Source distribution of a class which uses dynamic dispatch can become broken looking for a missing subVI
if you build a source distribution and a dynamic dispatch node is wired with a child class, the node can fail to be renamed and the code is thus broken looking for a missing subVI

Workaround: Create the distribution without renaming, and then rename it after creation

Reported Version: 8.6.1  Resolved Version: 2013  Added: 02/04/2013
389991

Return
Memory leak when calling LabVIEW DLLs from C with new threads.

Workaround: This issue has been fixed in the LabVIEW 2012 SP1 f3 Patch

Reported Version: 2009  Resolved Version: 2013  Added: 06/19/2013
305978

Return
Save As Duplicate with Include All Dependencies makes a Copy of the instr.lib Folder.
Include All Dependencies option in Save As does not ignore files from laview\instr.lib folder.

Workaround: Choose "Select contents to copy" and uncheck instr.lib

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/02/2013
392232

Return
Autopreallocate Arrays and Strings VI Property Can Crash LabVIEW when not in FPGA Context
Changing an FPGA VI to run in a context other than FPGA does turn off the VI property to Autopreallocate arrays and strings if it was previously turned on. Running a VI that has this property on and manipulates arrays or strings can cause LabVIEW to crash.

Workaround: Uncheck the Autopreallocate arrays and strings VI property for the VI.

Reported Version: 2010  Resolved Version: N/A  Added: 08/02/2013
408790

Return
Palette Editor Cannot Add LabVIEW Classes
LabVIEW Classes are an available option to be added to palettes, but adding them will not take effect.

Workaround: If your goal is to allow dropping of the class control or constant, you can create a custom control (not a typedef) that has the class on it's panel and add the custom control to the palettes. If your goal is to add the LabVIEW Class as a linked library, you can do so programmatically with Write Palette.vi.

Reported Version: 2009  Resolved Version: N/A  Added: 08/02/2013
453896

Return
Error message encountered during TestStand Deployment Utility build process may show incorrect list of VIs
If a VI linking error occurs while building a TestStand deployment, an error message is generated with a list of VIs causing the error. In some cases, this list may be incorrect or incomplete.

Workaround: This issue is fixed in the LabVIEW 2013 SP1 f2 Patch

Reported Version: 2010 SP1  Resolved Version: 2014  Added: 03/31/2014
465817

Return
LabVIEW converts a Double Precision numeric "NaN" value to integer data types differently since LabVIEW 2010
For example, when converting to U32, LabVIEW 2009 converts a "NaN" Double Precision numeric to 0. In LabVIEW 2010, "NaN" is converted to 4294967295 for a U32.

Workaround: Check if the numeric is NaN with the "Not a Number/Path/Refnum?" Function.

Reported Version: 2010 SP1  Resolved Version: 2014  Added: 04/15/2014
372668

Return
The channel order is incorrect for the first TDMS group after using NI_MinimumBufferSize property.

Workaround: Do not wire group and channel information to the TDMS Set properties function when setting NI_MinimumBufferSize.

Reported Version: 2009  Resolved Version: 2014  Added: 05/12/2014
445175

Return
Two or more Static VI References between the same VIs with different strictness can result in broken executables from Application Builder
The broken executable displays the error message: "This VI is not executable. The full development version of LabVIEW is required to fix the errors."

Workaround: There are multiple potential workarounds:1. In the exectuable's build spec, uncheck the "Remove unused polymorphic VI instances" option under Additional Exclusions2. Use the old method of calling a VI using the Run VI method3. Use a Strict type specifier VI refnum instead of a Static VI reference connected to the Open VI Reference

Reported Version: 8.0.1  Resolved Version: 2014  Added: 07/30/2014

Document last updated on 7/31/2014

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).