Specifies the description entered for the calibration of the channel. Not supported Not supported in VIs that run in a web application 22A4 attr22A4.html

Specifies the name of the operator who performed the channel calibration. Not supported Not supported in VIs that run in a web application 22A3 attr22A3.html

Specifies the voltage level at which to recognize waveform repetitions. You should select a voltage level that occurs only once within the entire period of a waveform. You also can select a voltage that ...

Specifies the units to use to return acceleration measurements from the channel. Not supported Not supported in VIs that run in a web application g 10186 1 g is approximately equal to 9.81 m/s/s. m/s^2 ...

Specifies a gain factor to apply to the channel. Not supported Not supported in VIs that run in a web application 1818 attr1818.html

Specifies whether to synchronize the AC excitation source of the channel to that of another channel. Synchronize the excitation sources of multiple channels to use multichannel sensors. Set this property ...

Specifies whether to enable input limits fault detection. Not supported Not supported in VIs that run in a web application 30FF attr30FF.html

Specifies the timing mode of the ADC when AI.ADCTimingMode is Custom. Not supported Not supported in VIs that run in a web application 2F6B attr2F6B.html

Specifies the level of the upper limit for input limits detection. An input sample outside the upper and lower bounds causes a fault. Note: Fault detection applies to both positive and negative inputs. ...

Specifies the coupling for the channel. Not supported Not supported in VIs that run in a web application AC 10045 Remove the DC offset from the signal. DC 10050 Allow NI-DAQmx to measure all of the signal. ...

Specifies how often to measure ground. NI-DAQmx subtracts the measured ground voltage from every sample. Not supported Not supported in VIs that run in a web application None 10230 Do not perform an autozero. ...

Specifies the units to use to return current measurements from the channel. Not supported Not supported in VIs that run in a web application Amps 10342 Amperes. From Custom Scale 10065 Units a custom scale ...

Specifies by how much to compensate for offset in the signal. This value can be between 0 and 127. Not supported Not supported in VIs that run in a web application 17F1 attr17F1.html

Specifies in ohms the external shunt resistance for current measurements. Not supported Not supported in VIs that run in a web application 17F3 attr17F3.html

Specifies the number of bits to return in a raw sample when AI.RawDataCompressionType is set to Lossy LSB Removal. Not supported Not supported in VIs that run in a web application 22D9 attr22D9.html

Specifies the frequency in Hertz that corresponds to the -3dB cutoff of the filter. Not supported Not supported in VIs that run in a web application 1803 attr1803.html

Specifies the data transfer mode for the device. Not supported Not supported in VIs that run in a web application DMA 10054 Direct Memory Access. Data transfers take place independently from the application. ...

Specifies under what condition to transfer data from the onboard memory of the device to the buffer. Not supported Not supported in VIs that run in a web application Onboard Memory More than Half Full ...

Specifies the DC value to add to the input range of the device. Use AI.Rng.High and AI.Rng.Low to specify the input range. This offset is in the native units of the device . Not supported Not supported ...

Indicates the coefficients of a polynomial equation that NI-DAQmx uses to scale values from the native format of the device to volts. Each element of the array corresponds to a term of the equation. For ...

Specifies the center frequency of the passband for the digital filter. Not supported Not supported in VIs that run in a web application 30C3 attr30C3.html

Specifies the width of the passband centered around the center frequency for the digital filter. Not supported Not supported in VIs that run in a web application 30C4 attr30C4.html

Specifies the digital filter coefficients. Not supported Not supported in VIs that run in a web application 30C7 attr30C7.html

Specifies the units to use to return linear position measurements from the channel. Not supported Not supported in VIs that run in a web application Meters 10219 Meters. Inches 10379 Inches. From Custom ...

Specifies an array of coefficients for the polynomial that converts pre-scaled values to scaled values. Each element of the array corresponds to a term of the equation. For example, if index three of the ...

Specifies the lowpass cutoff frequency of the digital filter. Not supported Not supported in VIs that run in a web application 30C1 attr30C1.html

Specifies in ohms the desired value of the internal shunt calibration A resistor. Not supported Not supported in VIs that run in a web application 2F78 attr2F78.html

Specifies the maximum number of simultaneous USB transfers used to stream data. Modify this value to affect performance under different combinations of operating system and device. Not supported Not supported ...

Specifies the maximum size of a USB transfer request in bytes. Modify this value to affect performance under different combinations of operating system and device. Not supported Not supported in VIs that ...

Specifies the decibel reference level in the units of the channel. When you read samples as a waveform, the decibel reference level is included in the waveform attributes. Not supported Not supported in ...