Filtered Results

Creates channel(s) to generate digital pulses defined by the amount of time the pulse is at a high state and the amount of time the pulse is at a low state. The pulses appear on the default output terminal ...

Reads one or more pairs of pulse frequency and duty cycle from a counter input task. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter 1D ...

Creates a channel to count the number of rising or falling edges of a digital signal. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a ...

Creates a channel to measure the angular velocity of a digital signal. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this ...

Creates channel(s) that use an accelerometer to measure acceleration. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical ...

Configures the task to stop the acquisition when the device acquires all pretrigger samples; an analog signal reaches the level you specify; and the device acquires all post-trigger samples. LabVIEW NXG ...

Writes the specified binary value to the DAC on the specified physical channel at the specified range. Specify at least two calibration points for each physical channel and range you calibrate. Use 0 and ...

Indicates an array containing the names of the banks in the FieldDAQ. Not supported Not supported in VIs that run in a web application 29B7 attr29B7.html

Indicates the serial number of the sensor. Not supported Not supported in VIs that run in a web application 21DC attr21DC.html

Specifies the voltage level for the sensor's power supply. Not supported Not supported in VIs that run in a web application 21D9 attr21D9.html

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 222D attr222D.html

Specifies the names of the digital lines or ports on which to detect falling edges. The lines or ports must be used by virtual channels in the task. You also can specify a string that contains a list or ...

Specifies the input terminal configuration. Not supported Not supported in VIs that run in a web application Differential 10106 Differential. RSE 10083 Referenced Single-Ended. 30A1 attr30A1.html

Adjusts the external calibration constants for an NI 9251 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9251 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration gain constants for an NI 9209 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9209 Gain Calibration.vi ...

Creates a route between a source and destination terminal. The route can carry a variety of digital signals, such as triggers, clocks, and hardware events. The source and destination terminals can be on ...

Creates channel(s) that use a Wheatstone bridge to measure torque. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical values ...

Creates channel(s) to measure voltage. Use this instance for custom sensors that require excitation. You can use the excitation to scale the measurement. You must configure the physical channel(s) with ...

Creates channel(s) to measure voltage. You must configure the physical channel(s) with TEDS information to use this node. If the measurement requires the use of internal excitation or you need excitation ...

Creates channel(s) that use(s) a charge-based sensor to measure acceleration. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Acceleration-Accelerometer).vi ...

Reads a single pair of pulse high and low times from a counter input task. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter Pulse Time 1Chan ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors whose specifications provide a table of electrical values and the corresponding physical values. ...

Queries the status of the task and indicates if it completed execution. Use this node to ensure that the specified operation is complete before you stop the task. LabVIEW NXG does not support FPGA devices ...

Creates channel(s) to measure resistance. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Resistance).vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors whose specifications provide a table of electrical values and the corresponding physical values. When ...

Returns the reference values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9238 Calibration ...

Creates channel(s) to duty cycle of a digital pulse. Connect the input signal to the default input terminal of the counter, unless you select a different input terminal. With the exception of devices that ...

Creates a channel to measure the frequency of a digital signal. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this node, because ...

Showing 61-90 of 2163 results