Specifies the type of trigger to use to expire a watchdog task. Not supported Not supported in VIs that run in a web application Digital Edge 10150 Trigger on a rising or falling edge of a digital signal. ...

Internal Channel Name Description _aignd_vs_aignd A differential terminal with the positive and negative terminals both connected to the ground reference for analog input. _ao0_vs_aognd A differential ...

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2F00 attr2F00.html

Specifies the name of a virtual channel or terminal where there is an analog signal to use as the source of the trigger. Not supported Not supported in VIs that run in a web application 1373 attr1373.html ...

Specifies for NI-DAQmx to map hardware registers to the memory space of the application, if possible. Normally, NI-DAQmx maps hardware registers to memory accessible only to the kernel. Mapping the registers ...

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2224 attr2224.html

On an X Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

The following table is a list of internal physical channels for all E Series devices. Different E Series devices have different subsets of channels. These channels are typically for self-calibration, and ...

On an S Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

Specifies how DAQmx Read waits for samples to become available. Not supported Not supported in VIs that run in a web application Wait For Interrupt 12523 Check for available samples when the system receives ...

Not all E Series, M Series, S Series, and C Series devices support analog triggering. Refer to the specifications for your device to determine if your device supports analog triggering. Many C Series, ...

Terminal Names Explanation OnboardClock An alias for the terminal within a device where the default source for a clock can be found. If your application does not set the source of a clock (or uses an empty ...

Specifies the terminal of the signal to use as the Master Timebase. On an E Series device, you can choose only between the onboard 20MHz Timebase or the RTSI7 terminal. Not supported Not supported in VIs ...

You typically use an integer format to read or write entire ports. In integer format, each digital channel you read or write must fit into one integer. For example, if the largest channel in a task consists ...

Specifies the logic level behavior on the count reset line. Not supported Not supported in VIs that run in a web application Logic Level Pull-up 16064 High logic. None 10230 Supply no excitation to the ...

Specifies on which edge of the input signal to begin pulse measurement. Not supported Not supported in VIs that run in a web application Rising 10280 Rising edge(s). Falling 10171 Falling edge(s). 2F05 ...

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2215 attr2215.html

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2F0F attr2F0F.html

Use the DAQmx - Data Acquisition Nodes with NI-DAQmx hardware devices to develop instrumentation, acquisition, and control applications. Refer to your readme file for a complete listing of devices that ...

Adjusts the external calibration constants for an NI 9265 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9265 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Creates a custom scale that scales values proportionally from a range of pre-scaled values to a range of scaled values. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates a custom scale that uses an nth order polynomial equation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Scale (Polynomial).vi :/lvdaqmx.chm::/DAQmx ...

Returns the reference values to be measured by a reference device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 4322 Calibration Adjustment Points.vi ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Performs shunt calibration for the specified channels using a strain gage sensor. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Perform Shunt Calibration ...

Creates channel(s) to measure strain. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Strain-Strain Gage).vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) to generate current. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AO-Current-Basic).vi :/lvdaqmx.chm::/DAQmx ...