Filtered Results

Specifies the input terminal configuration. Not supported Not supported in VIs that run in a web application Differential 10106 Differential. RSE 10083 Referenced Single-Ended. 30A1 attr30A1.html

Specifies the units to use to return angular position measurements from the channel. Not supported Not supported in VIs that run in a web application Degrees 10146 Degrees. Radians 10273 Radians. Ticks ...

Specifies an additional amount of time to wait between when the sample is written by the host device and when the sample is output by the DAC. This delay adjustment is in addition to the value indicated ...

Specifies on which edges to increment or decrement the counter. Not supported Not supported in VIs that run in a web application Rising 10280 Rising edge(s). Falling 10171 Falling edge(s). 697 attr697.html ...

Specifies the zero-to-peak amplitude of the waveform to generate in volts. Zero and negative values are valid. Not supported Not supported in VIs that run in a web application 2A1A attr2A1A.html

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 21F2 attr21F2.html

Specifies the frequency of the waveform to generate in hertz. Not supported Not supported in VIs that run in a web application 2A19 attr2A19.html

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 21F3 attr21F3.html

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. This property does not affect the minimum pulse width recognized by the device, but setting ...

Indicates if the virtual channel was initialized using a TEDS bitstream from the corresponding physical channel. Not supported Not supported in VIs that run in a web application 2983 attr2983.html

Specifies the input terminal configuration. Not supported Not supported in VIs that run in a web application Differential 10106 Differential. RSE 10083 Referenced Single-Ended. 309D attr309D.html

Specifies on which edge of the signal to reset the count. Not supported Not supported in VIs that run in a web application Rising 10280 Rising edge(s). Falling 10171 Falling edge(s). 2FB2 attr2FB2.html ...

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 2FB3 attr2FB3.html

Specifies the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2FB4 attr2FB4.html

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 2FB6 attr2FB6.html ...

Specifies the input of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 2FB5 attr2FB5.html

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. Not supported Not supported in VIs that run in a web application 2FB7 attr2FB7.html

Specifies whether to reset the count on the active edge specified with CI.CountEdges.CountReset.Term. Not supported Not supported in VIs that run in a web application 2FAF attr2FAF.html

Specifies the method or equation form that the thermocouple scale uses. Not supported Not supported in VIs that run in a web application Polynomial 10449 Scale values by using an Nth order polynomial equation. ...

Specifies the value to reset the count to. Not supported Not supported in VIs that run in a web application 2FB0 attr2FB0.html

Specifies the 'A' constant of the Steinhart-Hart thermistor equation. Not supported Not supported in VIs that run in a web application 18C9 attr18C9.html

Specifies how to count and interpret the pulses the encoder generates on signal A and signal B. X1, X2, and X4 are valid for quadrature encoders only. Two Pulse Counting is valid for two-pulse encoders ...

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 21F6 attr21F6.html

Specifies the maximum number of simultaneous USB transfers used to stream data. Modify this value to affect performance under different combinations of operating system and device. Not supported Not supported ...

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 21F9 attr21F9.html ...

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 21F8 attr21F8.html

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2206 attr2206.html

Specifies whether to increment or decrement the counter on each edge. Not supported Not supported in VIs that run in a web application Count Up 10128 Increment counter. Count Down 10124 Decrement counter. ...

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 2207 attr2207.html

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 30F4 attr30F4.html ...

Showing 271-300 of 2163 results
10 of 73 pages