Filtered Results

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

Creates channel(s) that use a thermocouple to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Reads one or more raw, 16-bit signed integer samples from a task. Use this instance with devices that use 16-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 32-bit signed integer samples from a task. Use this instance with devices that use 32-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more unscaled 16-bit unsigned integer samples from a task that contains one or more analog input channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Gets the power up states for digital physical lines. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get Power Up States (Digital).vi :/lvdaqmx.chm::/DAQmx ...

Reads one or more 32-bit unsigned integer samples from a counter task. Use an instance that reads 32-bit unsigned integers when NI-DAQmx returns counter samples unscaled, such as for event counting. If ...

Reads an unscaled 32-bit unsigned integer sample from one or more counter tasks. If the sample unit of your task cannot be represented by an integer, data is returned in the unit of clock ticks. LabVIEW ...

Reads one or more unscaled 32-bit unsigned integer samples from one or more counter tasks. If the sample unit of your task cannot be represented by an integer, data is returned in the unit of clock ticks. ...

Reads a 32-bit unsigned integer sample from a counter task. Use an instance that reads 32-bit unsigned integers when NI-DAQmx returns counter samples unscaled, such as for event counting. If the sample ...

Reads one or more pairs of pulse high and low tick counts from a counter input task. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter 1D ...

Reads one or more pairs of pulse high and low times from a counter input task. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter 1D Pulse ...

Reads one or more raw, 32-bit signed integer samples from a task. Use this instance with devices that use 32-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 8-bit signed integer samples from a task. Use this instance with devices that use 8-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Reads one or more 8-bit unsigned integer samples from a task that contains a single digital input channel. Use an instance that reads 8-bit unsigned integers for devices with up to eight lines per port. ...

Reads a single 8-bit unsigned integer sample from each channel in a task that contains one or more digital input channels. Use an instance that reads 8-bit unsigned integers for devices with up to eight ...

Routes a control signal to the terminal you specify. The output terminal can reside on the device that generates the control signal or on a different device. You can use this node to share clocks and triggers ...

Creates channel(s) that use an LVDT to measure linear position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-LVDT).vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use(s) an RVDT to measure angular position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-RVDT).vi ...

Creates channel(s) that use an eddy current proximity probe to measure position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-EddyCurrentProxProbe).vi ...

Creates channel(s) to measure resistance. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Resistance).vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use a thermocouple to measure temperature. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Temperature-Thermocouple).vi ...

Creates channel(s) to measure voltage. If the measurement requires the use of internal excitation or you need excitation to scale the voltage, use the Custom Voltage with Excitation measurement type for ...

Creates channel(s) to measure voltage RMS, the average (mean) power of the acquired voltage. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel ...

Creates a channel for continually generating a waveform on the selected physical channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel ...

Creates channel(s) to generate voltage. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AO-Voltage-Basic).vi :/lvdaqmx.chm::/DAQmx ...

Creates a channel to measure the frequency of a digital signal. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this node, because ...

Creates a channel that uses a special purpose counter to take a timestamp and synchronizes that counter to a GPS receiver. With the exception of devices that support multi-counter tasks, you can create ...

Showing 1-30 of 2275 results
1 of 76 pages