Filtered Results

Select one or more channels you wish to configure. Hover over a channel row and click the Configure gear . The configure gear appears when selecting multiple channels of the same data type (analog, digital, ...

Add and configure signals to use in your Channel specification. Use any of the following options that apply to the devices in your system: Configure sensors in your Channel Specification Configure digital ...

Low-Speed CAN requires termination at the Low-Speed CAN transceiver instead of on the cable. The termination requires two resistors: RTH for CAN_H and RTL for CAN_L. This configuration allows the NXP fault-tolerant ...

You can view your hardware in the Channel Specification to begin configuring and managing the signals in your system, such as in the following example system: Available device channels are beneath the ...

Complete the following steps to apply scaling to your configured sensor. Click the Configure gear on the channel of the device you wish to scale. The channel configuration dialog opens. In the Scaling ...

Navigate to the Graphs palette on your Screen.flxscr document. Click the graph you want to use and drag it onto the Screen. Add the channels you want to visualize to the graph as shown in the Mapping an ...

Select one or more channels you wish to configure. Hover over a channel row and click the Configure gear . The configure gear appears when selecting multiple channels of the same data type (analog, digital, ...

Add counters to a project by configuring signals in the Channel Specification. Use these steps to configure counters for counter modules, such as the NI-9361, and onboard counters by enabling the line ...

Refer to the following information to configure your device channels. Configuring I/O Channels Configuring an Automotive Bus Configuring Calculated Channels After you configure your channels, you can start ...

Select one or more channels you wish to configure. Hover over a channel row and click the Configure gear . The configure gear appears when selecting multiple channels of the same data type (analog, digital, ...

Add a channel produced by applying either a lowpass or a highpass Butterworth filter to an existing hardware channel. The lowpass or highpass filter channel displays filtered data that excludes any noise ...

Add a calculated channel to analyze or scale data from existing hardware channels. A calculated channel produces a new value based on calculations performed on other channels in the system. On the Channel ...

Select one or more channels you wish to configure. Hover over a channel row to see the Configure gear . Click the gear for the channel or channels you wish to configure. The configure gear appears when ...

Extend the functionality of FlexLogger by adding a custom plugin to your project. What to UseThe FlexLogger Plugin Development Kit guides you through planning, creating, and testing your custom plugins ...

Low-Speed CAN requires termination at the Low-Speed CAN transceiver instead of on the cable. The termination requires two resistors: RTH for CAN_H and RTL for CAN_L. This configuration allows the NXP fault-tolerant ...

You can view your hardware in the Channel Specification to begin configuring and managing the signals in your system, such as in the following example system: Available device channels are beneath the ...

In your Logging specification document, select a Start condition for your trigger. Selecting any Triggering conditions will enable the trigger. Select from the following trigger start conditions: Test ...

Click the Export button from the Alarm History pane. If necessary, specify the desired File location from the Export to CSV File Format dialog. If necessary, set the export format settings by going to ...

Access your project documents and files in the Navigation pane on the left of your view. Project Files TabThe Project Files tab includes documents that enable you to define settings for your measurement ...

You can use test properties as placeholders when you configure your log file name and location. Refer to the Using Test Metadata as Placeholders for Log File Names and Locations topic for more information. ...

If there's a way we could shorten/condense this example, I can see a case for leaving it in this topic. But it's so much longer than the steps themselves the way it is now, which makes the topic less focused. ...

While the test is running, click the Add Note button in the toolbar. A dialog will open, timestamped with the time the button was clicked. Record any information you wish to include in the log file. Note ...

CAN interfaces are software representations of physical ports. Complete the following steps to adjust the port settings. Enable Termination, if necessary. Improperly configured Termination schemes might ...

LIN databases allow you to store frames and signals running on the network in a database, as well as information about which ECU is transmitting or receiving which data. This information also is needed ...

On the Logging Specification document, select Export automatically to CSV file format when logging completes. Specify the CSV file data rate, if necessary. All logged data channels are mapped to a common ...

You must have channels added and configured for your FlexLogger project in order to visualize data from your sensor signals. Refer to the Configuring Device Channels topic for more information. On the ...

FlexLogger supports both hardware and software filters for use in your project. Hardware filters offer a variety of filter type options to provide anti-aliasing and noise reduction with no CPU usage or ...

Complete the following steps to apply scaling to your configured sensor. Click the Configure gear on the channel of the device you wish to scale. The channel configuration dialog opens. In the Scaling ...

Hover over the channel row to see the Configure gear . Click the gear for the channel you wish to add a strain gage to. Select the desired Bridge Configuration. Specify the Bridge Resistance (if available), ...

Use these methods to set the history length for graphs that support hold and pan viewing control. Set the Default History Length Go to File Preferences and specify the history length for your graph type ...

Showing 1-30 of 83 results
1 of 3 pages