The following items are known issues for NI-WSN 1.1.0.
CAR ID | CAR Description | Workaround |
---|---|---|
204188 | Nodes connecting to RT Gateway introduce up to 9 milliseconds of jitter. | |
Rebooting a gateway does not automatically deploy nodes that have never been deployed. | Create a LabVIEW Project, and manually deploy the nodes. | |
213599 | In certain situations, the 9792 Wireless Activity light may remain on. | |
210976 | Configuration Import/Export in MAX reports errors when using the .nce file type. | Ignore the errors and continue, or use the .wsn file type. |
176348 | Deploying Configuration while running a VI causes VI to temporarily return invalid data | Stop VI before deploying configuration |
176451 | Firmware version in MAX does not distinguish programmed nodes from non-programmed nodes. | |
156917 | MAX does not show progress of node firmware update without manual refresh | Manually refresh MAX |
154363 | Changing Node ID in Project Does Not Update Node Name | When changing ID, also update node name |
174982 | Windows 2000 does not display some drop down lists correctly | |
174980 | End Nodes remain on longer than anticipated when it has failed to join a network | |
159167 | Cannot Change Node Type (3202, 3212) After Node has been Added | Ensure proper node type is selected when adding |