From Friday, April 19th (11:00 PM CDT) through Saturday, April 20th (2:00 PM CDT), 2024, ni.com will undergo system upgrades that may result in temporary service interruption.
We appreciate your patience as we improve our online experience.
From Friday, April 19th (11:00 PM CDT) through Saturday, April 20th (2:00 PM CDT), 2024, ni.com will undergo system upgrades that may result in temporary service interruption.
We appreciate your patience as we improve our online experience.
Bug ID |
Fixed Issue |
Has Run-Time Impact? |
299976 | LabWindows/CVI can corrupt files on some network shares when saving a file after deleting some of its contents. | No |
299674 | Pasting unicode data copied from the clipboard can cause a crash. | No |
295529 | Changing only the type of a custom configuration does not trigger a rebuild of your project. | No |
295228 | Add Watch Expression context menu item incorrectly dimmed in watch window. | No |
294443 | "Index out of range" error in Edit Columns/Cells dialog. | No |
294960 | Switching execution target and starting to debug project crashes LabWindows/CVI when a watchpoint exists. | No |
293875 | Debugging a project in an unnamed workspace results in duplicate save dialog boxes. | No |
292892 | The LabWindows/CVI Visual Studio wizards add the version-specific ProgramData include path incorrectly. | No |
291368 | Line numbers are missing from Standard I/O window. | Yes |
290057 | Copying a control from one panel to the other in the User Interface Editor can cause the Attribute Browser to display incorrectly. | No |
289945 | Selecting a .lib instead of a .dll from the Generate DLL Import Library file dialog box causes LabWindows/CVI to crash. | No |
288104 | Changing any environment option while in an untitled workspace results in an error. | No |
283634 | The LabWindows/CVI Visual Studio Conversion Wizard fails for some projects that reference National Instruments modular instruments drivers. | No |
282844 | LabWindows/CVI does not allow users to save files following an exception. | No |
282612 | Editing a menu associated with a panel on an unsaved UIR can cause LabWindows/CVI to crash. | No |
279028 | Enabling or disabling profiling does not trigger a rebuild of your project. | No |
277640 | The User Interface Browser may not update when Find UI Object is selected from a source file. | No |
258506 | The Attribute Browser Find text box might incorrectly filter attributes when double-clicking a control in the User Interface Browser. | No |
258505 | Selecting Create New File on a project folder results in an invalid file. | No |
Bug ID |
Fixed Issue |
Has Run-Time Impact? |
285633 | LabWindows/CVI might crash if you create a panel with a very long title. | No |
302494 | Memory leak when using ATTR_COPY_ORIGINAL_DATA=0 and getting a scaled bitmap of a graph control. | Yes |
290737 | InetSendMail can crash if the To: field exceeds 250 bytes. | Yes |
283981 | Performance of many TDMS functions deteriorates more quickly than expected as total group and channel counts become very large. | Yes |
253304 | TDMS Files with very high channel counts might be slow to open. | Yes |
Bug ID |
Fixed Issue |
Has Run-Time Impact? |
284842 | The GetTableCellRangeVals and SetTableCellRangeVals functions do not work for string cell types in a 64-bit application. | Yes |
294725 | Adding or removing an item from a tree that is not in edit mode might, in rare circumstances, cause a crash. | Yes |
286688 | The menu text for a menu using a non-metafont rotates when a panel with Scale Contents on Resize enabled is resized. | Yes |
282946 | Right justified numeric controls can draw their text incorrectly. | No |
281083 | The y-axis name of a strip chart control might be drawn incorrectly when the y-axis autoscales. | Yes |
281082 | A strip chart legend may not be drawn correctly if it overlaps the strip chart plot area. | Yes |
280705 | You cannot enter numbers in scientific notation into numeric controls holding 64-bit integers. | Yes |
280320 | Table scroll bars do not redraw when scrolling a table with the keyboard. | Yes |
279916 | The defaultFileSpec parameter of the FileSelectPopup function does not work correctly. | Yes |
276443 | A tab inserted anywhere but the end of the list will use the wrong image. | Yes |
276442 | Displaying a file select popup panel from a panel with a tab control might disrupt the panel z-plane order. | Yes |
258827 | Block and sweep strip chart modes do not scroll properly. | Yes |
303247 | Strip chart x-axis divisions do not maintain proper spacing during scrolling. | Yes |
302870 | UI Localizer can crash when clicking Next on the last item of a tree control. | No |
Bug ID |
Fixed Issue |
Has Run-Time Impact? |
257782 | The Resource Tracking window does not track thread local variable handles. | No |
298184 | Non-Fatal UP errors can sometimes display with only the message %%s. | Yes |
275934 | Including the http.h Win32 API header file can result in missing function prototype compile errors. | No |
295530 | Watch points created for custom configurations might not work without modifications. | No |
258835 | Using clang 1.0 as your active release compiler might result in link errors if you include windows.h from more than one source file. | No |
Bug ID |
Fixed Issue |
Has Run-Time Impact? |
292539 | Opening a distribution that was created in LabWindows/CVI 7.1 and earlier can cause a crash during conversion. | No |
292805 | An application whose installer includes only the Network Variable Support sub-item might not run correctly in a minimally configured target computer. | Yes |
292521 | An application whose installer includes only the Network Variable Support sub-item might run slower than expected in a minimally configured target computer. | Yes |
291813 | Distributions with .inf files fail to install after checking module dependencies. | Yes |
291452 | An application whose installer includes only the Standard Run-Time sub-item might run with a Mesa.dll could not be found error in a minimally configured target computer. | Yes |
290986 | A 32-bit application whose installer includes only the ActiveX Container Support sub-item might not run correctly in a minimally configured target computer. | Yes |
290386 | Uninstalling LabWindows/CVI distributions from some non-English operating systems fails. | No |
286606 | In a multi-project workspace, when editing a distribution, the output files of a project might incorrectly refer to the output files of a different project. | No |
278742 | In a distribution, the path to the CHM help file for an ActiveX server file is incorrect. | No |
Bug ID |
Fixed Issue |
Has Run-Time Impact? |
296663 | DIAdem automation example reports ActiveX error. | Yes |
296660 | ActiveX Iedemo example does not work with newer versions of IE. | Yes |
283042 | A LabWindows/CVI ActiveX server can crash while shutting down if there are open client connections to the server. | Yes |
Bug ID |
Fixed Issue |
Has Run-Time Impact? |
248829 | The function GaussHG returns NaN for X values less than 0. | Yes |
280209 | Calling IIRCascadeFiltering in a loop produces erroneous results. | Yes |
Bug ID |
Fixed Issue |
Has Run-Time Impact? |
287394 | HTML and XML files generated from source code contain an extra asterisk for output parameters in function prototype. | No |
277253 | Non-void pointer types in function prototypes have an extra asterisk in the LabWindows/CVI help. | No |
258354 | CNVProcessIsRunning may incorrectly report that the process is running if the program is run as a startup program. | Yes |