能否在一个使用LabWindows™/CVI 创建的DLL中使用DataSocket,并把它下载到LabVIEW Real-Time 终端中?
不能在RT端通过LabWindows/CVI 使用DataSocket。虽然在生成支持RT 终端的DLL时 (Build »Target Settings»LabVIEW Real-time only)不会报错,但是在当调用DLL时候就会获得运行错误。我们暂时没有增加这个功能的计划,但是LabWindows/CVI 7.0和更高的版本已经提供支持RT终端的TCP通信协议。
LabWindows/CVI Real-Time Module 8.1和后续版本支持RT终端上在LabWindows/CVI中使用网络共享变量进行通信。使用LabWindows/CVI Real-Time module 可以实现在RT终端上实现LabWindows/CVI 网络共享变量、LabVIEW共享变量、Measurement Studio Network 网络共享通信。
|