当运行NI产品的安装文件时,有错误1406



主要软件: LabVIEW Development Systems>>LabVIEW Full Development System
主要软件版本: 7.1
主要软件修正版本: N/A
次要软件: Other NI Software, Driver Software, Instrument Drivers/IVI, Calibration Executive, Motion Assistant, Vision Assistant, DIAdem, Switch Executive, LabVIEW Run-Time Engine, LabWindows/CVI Run-Time Engine, LabVIEW Toolkits, Measurement Studio Add-ons, LabWindows/CVI Add-ons, LabWindows/CVI Development Systems, Measurement Studio, LabVIEW Development Systems, LabVIEW Modules, Lookout, Driver Software>>Vision Acquisition Software

问题: 当我运行LabVIEW的安装文件(或者其他NI软件产品)时,我就看到一个错误对话框,如下信息:
什么引起这个问题,我如何解决这个错误?

解答:

  这个问题与windows的注册表的限制有关系(磁盘上注册表的特定键大小或者总大小).

  微软意识到这个问题并且发布了补丁来修复这个问题。从Windows Installer 1.0或1.2升级到Windows Installer 2.0应当可以解决这个问题。 请参考下面的相关链接部分,里面有到微软知识库的链接。

  安装了这个更新后,假如你仍然看到这个错误,那么注册表有可能已经满了。很多时候注册表被不再使用的键填满,可以安全的删除。对于不是完全理解的任何东西,都不要删除。注册表对于Windows的操作非常重要,必须小心处理。假如你认为适用于你的情况,在因特网上就有很多可用的免费软件和共享软件用于注册表清理。

  另外可能的原因是安装程序输入的键太长。一个可能的原因是非常长的路径名。你可以尽量安装到更简单的,更短的目录或路径下。

  假如你使用Windows 2000,你可以通过下面的步骤来增大注册表:

    1. 右击 我的电脑

    2. 选择 属性

    3. 在属性窗口中选择高级

    4. 点击 性能 选项

    5. 在性能选项窗口,点击 改变

    6. 增加最大注册表大小

   

  •  
  •  



    相关链接: Microsoft Knowledgebase: Windows Installer error 1406