NI PXI-103x 机箱同步疑难解答



硬件: PXI/CompactPCI, PXI/CompactPCI>>Chassis>>PXI-1031

问题: 我在NI PXI-103x机箱中路由同步信号时,没有获得期望的结果,什么原因呢?

解答:

NI PXI-103x机箱和其他机箱不同,它有一个开关来选择是否导出时钟到背板,在手册的1-8页提到过这一点(所有的PXI-103x 手册都在同一页,手册见附件所示),但是这一点经常被忽视。

你必须手动开关机箱背板的SW1 来使能或者禁用将外部时钟路由到外设插槽的功能。

这就是为什么你虽然已经将定时和同步模块放在了2槽,但是却得不到预期结果的原因。要获得更多的信息,请参考机箱的手册。



相关链接: Product Manuals: NI PXI-1031 User Manual (February 2004)
Product Manuals: NI PXI-1033 User Manual (August 2006)
Product Manuals: NI PXI-1036/PXI-1036DC User Manual (August 2005)
Developer Zone Example: NI-SYNC Route PXI_CLK10 to PFI Outputs- Developer Zone