使用M系列采集卡时,第二块sc-2345可以提供全部功能吗?



硬件: Multifunction DAQ (MIO)>>M Series>>PCI-6224, Multifunction DAQ (MIO)>>M Series>>PCI-6229, Multifunction DAQ (MIO)>>M Series>>PCI-6254, Multifunction DAQ (MIO)>>M Series>>PCI-6259, Multifunction DAQ (MIO)>>M Series>>PCI-6284, Multifunction DAQ (MIO)>>M Series>>PXI-6289, Multifunction DAQ (MIO)>>M Series>>PXI-6224, Multifunction DAQ (MIO)>>M Series>>PXI-6229, Multifunction DAQ (MIO)>>M Series>>PXI-6254, Multifunction DAQ (MIO)>>M Series>>PXI-6259, Multifunction DAQ (MIO)>>M Series>>PXI-6284

问题: 我正在对2块SC-2345与M系列采集板卡配合使用进行研究,我能通过连线至M系列板卡的方法来获取第二块SC-2345的全部功能吗?

解答:

使用NI-DAQmx 7.4,你可以在一个具有两个连接口否M系列设备使用SC-2345连接到Connector 1实现全部功能。下面是6224的输入输出引脚说明,其中有2个Connector。仔细的观察表明,两个连接器是相同的,因此,每个sc-2345可以提供完备的功能。唯一的例外是PFI引脚。这些引脚是不能通过第二个连接器进行访问的。
注:你不能对6225采集板卡使用第二个SC-2345,6225板卡在第二个Connector上有另外的模拟输入通道,这意味着6225不能和Sc-2345映射。

 



相关链接:
KnowledgeBase 41SGQNJX: Connecting Signals to the SC-2345
KnowledgeBase 3FEGFPK: Using SC-207x Signal Conditioning Accessories with M Series Data Acquisition (DAQ) Devices
Product Manuals: SC-2345/2350 Carrier User Manual and Specifications

附件:


6224Pinout.GIF - 6224Pinout.GIF



报告日期: 04/30/2005
最近更新: 08/24/2015
文档编号: 3KTL30Q8