Archived: LabVIEW 8.6 Touch Panel Module Known Issues

NI does not actively maintain this document.

This content provides support for older products and technology, so you may notice outdated links or obsolete information about operating systems or other relevant products.

Overview

This document has been archived and is no longer updated by National Instruments.

This document contains the LabVIEW 8.6 Touch Panel Module known issues that were discovered before and since the release of the LabVIEW 8.6 Touch Panel Module. Not every issue known to NI will appear on this list; it is intended to only show the severe and more common issues that can be encountered.

Known Issues

The following items are known issues in the LabVIEW 8.6 Touch Panel Module.

 Installation Known Issues
ID
Known Issue
(Windows 2000) The Touch Panel Module installs Microsoft ActiveSync 4.2. You might receive a Microsoft Office Outlook error that states Either there is no default mail client or the current mail client cannot fulfill the messaging request. Please run Microsoft Office Outlook and set it as the default mail client.

Workaround—You do not need to install Microsoft Outlook nor does Outlook have to be your default mail client. Click the OK button to continue installation.
The Touch Panel Module automatically installs ActiveSync 4.2 if ActiveSync is not already installed. When you install the Touch Panel Module and do not already have ActiveSync, the installer automatically reboots the computer without alerting you. To resolve this issue, rerun the installer (setup.exe) to complete the installation or install ActiveSync before you install the Touch Panel Module.

Workaround—Rerun the installer (setup.exe) to complete the installation or install ActiveSync before you install the Touch Panel Module.
If you are using the x86 TOUCH PANEL WINDOWS CE 4.2 Device Touch Panel target, you must manually download and install the eMbedded Visual Tools and Pocket PC 2003 SDK. 
If you install LabVIEW and the Touch Panel Module to custom locations that contain non-ASCII characters, errors occur when you build Touch Panel VIs into Touch Panel applications.

Workaround—Install LabVIEW and the Touch Panel Module to the default installation locations.
 General Known Issues
ID
Known Issue
117037
Passing a control reference through a zero-iteration For Loop can cause a crash.

Workaround—Use a local variable for the control reference instead of using the output tunnel from a zero-iteration For Loop.
Several front panel and block diagram objects behave differently when the execution target is a Touch Panel target. Refer to the Touch Panel Module book in the LabVIEW Help for information about different or unsupported front panel or block diagram functionality.
2W0DTEJU
The Touch Panel Module does not support significant digits.

Workaround—Use digits of precision instead.
If you flatten data that contains an extended precision or complex precision floating-point data type, the flattened data is incompatible with any other LabVIEW version or add-on except the Touch Panel Module.
3Q39UPZO
Any binary operation involving a dynamic data type and a non-scalar non-dynamic data type, such as a 1D array, does not work correctly.
44698H30
If you copy and paste global variables, you receive a link error when you try to build the Touch Panel VI into an application.
44698H30
When you create a VI that uses multiple global variables, do not copy controls from one global variable to another global variable. Controls copied from one global variable to another global variable result in errors when you build the Touch Panel VI into an application.
XON/XOFF flow control in serial communication causes a timeout if you use the Serial Compatibility VIs. This is not an issue if you use the VISA VIs and functions.
When a timestamp in a Touch Panel VI is rounded to the nearest integer, the timestamp is always rounded down to the next lowest integer. The effect of this behavior is that the Round to Nearest and Round to -Infinity functions produce the same output on timestamps.
3ZGG3OXE
LabVIEW stores colors as RGB values. Windows Mobile and Windows CE operating systems store colors as BGR values. If you place a color box constant inside of a nested array or cluster constant, the colors might render incorrectly because the red and blue components are exchanged when you build a Touch Panel VI into a Touch Panel application.

Workaround—Place the color box constant inside a single array or cluster constant on the block diagram and use the Build Array or Bundle function to nest the array or cluster.
Touch Panel VIs do not support the values of Z, X, or T in digital data controls and digital waveform controls. You can use values of 0, 1, L, and H.
ActiveSync is the default transport protocol in the Touch Panel Module. NI TPC-2012 does not support ActiveSync, so you must use FTP or the NI TPC Service to download your Touch Panel application to the NI TPC-2012.
The NI TPC devices do not support.wav files.
4BCFMCOI
The Touch Panel Module does not support creating a source distribution. If you right-click Build Specifications in the Project Explorer window and select New»Source Distribution from the shortcut menu, LabVIEW displays an error message in the Source Distribution Properties dialog box.
 Windows Vista Known Issues
ID
Known Issue
ActiveSync has been replaced with Windows Mobile Device Center, which you must download from www.microsoft.com, in Vista.
460E2GYF
If you install the Touch Panel Module on a computer that runs a non-English version of Vista, you might receive a Command line option syntax error. Type Command/? for Help error.

Workaround—Click the OK button to continue the installation.
 User Interface Known Issues
ID
Known Issue
117411
Users can select items in a tree indicator.

Workaround—Disable the tree indicator.
114766
If you select a multi-needle dial, gauge, or meter control, you can move only the current needle using keys. Pressing the <Tab> key moves the focus to the next control and not the next needle.
117311
If a dial is on a tab control but not on the initially displayed tab, the dial has the background rectangle color of the front panel instead of that of the tab control when the dial is shown.

Workaround—Make sure the tab that contains the dial is shown initially. Or, make sure that the background color of the tab is the same as the color of the front panel.
114955
Charts draw incorrectly when the number of points on screen exceeds the chart history length.

Workaround—Change the chart history length to accommodate the number of points drawn on the chart before it scrolls.
100031
The focus rectangle of the task ring control is partially visible and is not erased when the control is out of focus.
The 2D Boolean OK, Cancel, and Stop buttons do not support different text strings for TRUE and FALSE states.
49KH9R00
Scroll bars and multiline inputs/outputs are unsupported for string controls if you use the password display mode.
452AA2LL
3D borders on tank indicators do not scale with the rest of the indicator when you build a Touch Panel VI into an application.
444EN6Z0
Tab controls redraw slowly when you switch tabs. You might see shadows of the controls on the previous tab as LabVIEW redraws the controls on the current tab.
98987
Autoscaling of the y-axis for multiplot XY graphs is not supported.
46I8J200
Duplicate scales and plot legends are unsupported.
3O3AD7YF
Captions are always displayed behind the control.

Workaround—To resolve this issue for button controls, use Boolean text.
481814YF
You cannot use front panel data binding with radio buttons controls.
45216SX2
Arrays of DAQmx task name controls are not visible on the front panel of a Touch Panel application.

Workaround—You can use an array of DAQmx task name controls in a Touch Panel VI to write values even though the controls are not visible in the Touch Panel application.
 VIs, Functions, and Structures Known Issues
ID
Known Issue
111408
When you use the Display Message to User Express VI to display a message to a user, execution of other loops is halted.

Workaround—Use a subVI instead of a dialog box.
4H7C2000
The Escape XML and Unescape XML VIs are unsupported.
If you use the .NET Refnum, Event Callback Refnum, or Code Interface Nodes (CINs) in a Touch Panel VI, you receive an error if you try to build the VI into a Touch Panel application.
The Touch Panel Module does not support paths in the Not a Number/Path/Refnum? function.
You must use strict C code in Formula Nodes you use in Touch Panel VIs. However, LabVIEW does not check the C syntax in the Formula Node syntax while in edit mode. If you build a VI into a Touch Panel application that contains a Formula Node with non-strict C code, LabVIEW returns a general error.
The Configuration File VIs are unsupported.
 Building VIs into Applications Known Issues
ID
Known Issue
115992
The Optimize subVI calls build option is unsupported.
You might receive an error that states This property is writable only when the VI is in edit mode, or this method is available only when the VI is in edit mode. This error occurs if the VI is running on the host and you try to build the VI into an application. You must stop the VI on the host before building.
 Properties and Methods Known Issues
ID
Known Issue
The Touch Panel Module does not support the Update Value while Typing property for string objects.
 Graphs and Charts Known Issues
ID
Known Issue
The Touch Panel Module does not support plotting waveforms with more than 32,000 elements.
41768
If you are using the Zoom Chart of Graph VI and set the zoom style to Zoom to Rectangle, the x and y axis changes properly, but the graph is not correct.
378H49YF
If you are zooming a graph or chart in a Touch Panel application and draw with the log scale, it might appear as if nothing has happened.

Workaround—Choose a larger zoom rectangle.
Pull-down menus are not visible while a chart or graph is updating.

Workaround—You can place the mouse pointer on the pull-down menu to display it to make a selection.
 Tools and Drivers
ID
Known Issue
You must install the VISA driver to use VISA. Select Start»All Programs»National Instruments»VISA and select Windows CE for ARM Driver Installation or Windows CE for x86 Driver Installation, depending on which type of target you are using.
 Additions to the Help
ID
Known Issue
You can use the Label property to get a reference to the label object of a control or indicator.
You now can wire a control reference to the Zoom Chart or Graph VI and the Clear PDA Chart VI.
 Documentation Known Issues
ID
Known Issue
The Detailed Help link in the Context Help window does not open the correct topic for the Inline C Node.

Workaround—Open the LabVIEW Help by selecting Help»Search the LabVIEW Help. Click the Index tab and select Inline C Node.
The Help button in the Add/Remove Headers dialog box does not open the correct help topic.

Workaround—Open the LabVIEW Help by selecting Help»Search the LabVIEW Help. Click the Index tab and select Add/Remove Headers dialog box (Embedded Targets, PDA, TPC).

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).